Weiterhin alles Gute Michael Schumacher!
| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 1556 | Luft/Wasser | DIMPLEX - LA11TAS | 10.2 | 2018 | 180 | 2 | 2965.0 | * | 706.0 | 840.0 | 550.0 | 367.0 | 207.0 | 149.0 | 146.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 1556 | Luft/Wasser | DIMPLEX - LA11TAS | 10.2 | 2017 | 180 | 2 | 4813.9 | * | 946.6 | 561.0 | 549.0 | 484.0 | 275.4 | 151.5 | 144.3 | 147.0 | 211.6 | 380.5 | 545.5 | 417.5 | ||||||||||||||||||||||||||||||||||||||||||||||||||
| 1556 | Luft/Wasser | DIMPLEX - LA11TAS | 10.2 | 2016 | 180 | 2 | 4656.0 | * | 872.3 | 510.3 | 502.1 | 421.6 | 228.2 | 108.5 | 132.7 | 149.5 | 121.8 | 380.3 | 519.9 | 708.8 | ||||||||||||||||||||||||||||||||||||||||||||||||||
| 1556 | Luft/Wasser | DIMPLEX - LA11TAS | 10.2 | 2015 | 180 | 2 | 4948.1 | * | 724.0 | 845.0 | 604.9 | 463.1 | 214.0 | 181.2 | 140.2 | 134.0 | 211.8 | 376.0 | 518.3 | 535.6 | ||||||||||||||||||||||||||||||||||||||||||||||||||
| 1556 | Luft/Wasser | DIMPLEX - LA11TAS | 10.2 | 2014 | 180 | 2 | 2853.0 | * | 341.0 | 357.0 | 190.0 | 129.0 | 182.0 | 199.0 | 279.0 | 511.0 | 665.0 |
| NR | 1556 |
| Username | CuKHaus |
| Einbaujahr der WP | 2013-12-01 |
| PLZ des Wohnortes | 91365 |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | DIMPLEX - LA11TAS |
| modulierend | |
| Leistung (0/35) | 10.2 kW |
| berechneter Primärenergiebedarf | 46.3 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 45 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | Nein (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | FBH |
| elektr. Verbrauch WP ohne NA gem./DB | 2500 Watt DB |
| elektr. Verbrauch HP gem./DB | 35 Watt |
| elektr. Verbrauch WQ P gem./DB | 5 Watt |
| Stromzähler | > erfasst: |
| WMZ | |
| Mittlere Raumtemp. | 20.0 °C |
| Mittlere Wärmequellentemperatur | 0.0 °C |
| Heizung max. Vorlauf Temp. | 30.0 °C |
| Spreizung Heizkr. | 0.0 |
| Heizflaeche | 180 m² |
| Lüftung | Fenster |
| Personen | 2 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen |