Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1566 | Luft/Wasser | Rotex HPSU 508 BiV H/C | 8.0 | 2020 | 155 | 4 | 1004.2 | 2820.1 | 871 | 2.81 | 546.8 | 1539.6 | 476 | 2.82 | 457.4 | 1280.5 | 395 | 2.80 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
1566 | Luft/Wasser | Rotex HPSU 508 BiV H/C | 8.0 | 2019 | 155 | 4 | 3078.8 | 10485.6 | 2679 | 3.41 | 672.5 | 2169.1 | 456 | 3.23 | 388.5 | 1380.2 | 305 | 3.55 | 310.8 | 1229.6 | 289 | 3.96 | 239.5 | 924.7 | 203 | 3.86 | 119.8 | 477.8 | 106 | 3.99 | 111.9 | 465.6 | 172 | 4.16 | 81.5 | 396.5 | 119 | 4.87 | 47.3 | 155.1 | 32 | 3.28 | 74.4 | 228.3 | 76 | 3.07 | 201.0 | 639.7 | 175 | 3.18 | 334.3 | 993.7 | 286 | 2.97 | 497.3 | 1425.3 | 460 | 2.87 | ||||||||||||
1566 | Luft/Wasser | Rotex HPSU 508 BiV H/C | 8.0 | 2018 | 155 | 4 | 3437.6 | 12235.3 | 2772 | 3.56 | 580.1 | 2110.2 | 468 | 3.64 | 707.6 | 2232.2 | 459 | 3.15 | 475.6 | 1580.5 | 328 | 3.32 | 188.0 | 664.7 | 128 | 3.54 | 65.6 | 236.4 | 39 | 3.60 | 57.5 | 230.9 | 63 | 4.02 | 91.8 | 435.1 | 176 | 4.74 | 113.8 | 478.5 | 271 | 4.20 | 64.4 | 301.7 | 19 | 4.68 | 157.8 | 663.5 | 80 | 4.20 | 374.3 | 1362.8 | 314 | 3.64 | 561.1 | 1938.8 | 427 | 3.46 | ||||||||||||
1566 | Luft/Wasser | Rotex HPSU 508 BiV H/C | 8.0 | 2017 | 155 | 4 | 3498.1 | 12359.5 | 2594 | 3.53 | 791.7 | 2306.7 | 437 | 2.91 | 529.3 | 1724.1 | 305 | 3.26 | 353.1 | 1337.2 | 214 | 3.79 | 281.8 | 1107.7 | 177 | 3.93 | 133.3 | 553.0 | 98 | 4.15 | 69.9 | 244.4 | 46 | 3.50 | 67.1 | 299.3 | 63 | 4.46 | 39.4 | 112.2 | 10 | 2.85 | 88.1 | 395.1 | 129 | 4.48 | 157.4 | 687.5 | 251 | 4.37 | 354.4 | 1354.8 | 386 | 3.82 | 632.6 | 2237.5 | 478 | 3.54 | ||||||||||||
1566 | Luft/Wasser | Rotex HPSU 508 BiV H/C | 8.0 | 2016 | 155 | 3 | 3824.8 | 13215.9 | 2429 | 3.46 | 699.0 | 2103.0 | 361 | 3.01 | 531.0 | 1792.0 | 301 | 3.37 | 553.0 | 1866.0 | 308 | 3.37 | 327.1 | 1224.0 | 200 | 3.74 | 125.7 | 457.4 | 66 | 3.64 | 60.0 | 217.0 | 30 | 3.62 | 47.0 | 183.0 | 30 | 3.89 | 63.0 | 268.0 | 75 | 4.25 | 60.0 | 216.0 | 26 | 3.60 | 264.2 | 1221.9 | 276 | 4.62 | 459.1 | 1640.6 | 361 | 3.57 | 635.7 | 2027.0 | 395 | 3.19 | ||||||||||||
1566 | Luft/Wasser | Rotex HPSU 508 BiV H/C | 8.0 | 2015 | 155 | 3 | 3018.4 | 9708.7 | 1853 | 3.86 | 505.0 | 456.0 | 1443.0 | 3.16 | 369.0 | 1381.0 | 329 | 3.74 | 223.9 | 905.9 | 173 | 4.05 | 78.5 | 298.8 | 48 | 3.81 | 84.0 | 368.0 | 69 | 4.38 | 52.0 | 208.0 | 57 | 4.00 | 52.0 | 224.0 | 63 | 4.31 | 113.0 | 500.0 | 104 | 4.42 | 327.0 | 1395.0 | 369 | 4.27 | 331.0 | 1255.0 | 277 | 3.79 | 427.0 | 1730.0 | 364 | 4.05 | ||||||||||||||||
1566 | Luft/Wasser | Rotex HPSU 508 BiV H/C | 8.0 | 2014 | 155 | 3 | 750.0 | 750.0 |
NR | 1566 |
Username | Rapanter |
Einbaujahr der WP | 2014-11-01 |
PLZ des Wohnortes | 07751 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Bi |
Hersteller Typ | Rotex HPSU 508 BiV H/C |
modulierend | Ja |
Leistung (0/35) | 8.0 kW |
berechneter Primärenergiebedarf | 39.3 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 42 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 3300 Watt DB |
elektr. Verbrauch HP gem./DB | 45 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 31.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 155 m² |
Lüftung | zenKWLWR |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Kühlung im Sommer aktiv. |