Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
168 | Luft/Wasser | Siemens HLW 8 | 8.0 | 2023 | 231 | 4 | 1375.0 | 401.0 | 365.0 | 308.0 | 181.0 | 48.0 | 27.0 | 11.0 | 34.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
168 | Luft/Wasser | Siemens HLW 8 | 8.0 | 2022 | 231 | 4 | 2364.0 | 634.0 | 310.0 | 292.0 | 224.0 | 61.0 | 30.0 | 24.0 | 38.0 | 34.0 | 27.0 | 223.0 | 467.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
168 | Luft/Wasser | Siemens HLW 8 | 8.0 | 2021 | 231 | 4 | 2979.0 | 623.0 | 487.0 | 381.0 | 298.0 | 159.0 | 36.0 | 29.0 | 32.0 | 41.0 | 131.0 | 350.0 | 412.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
168 | Luft/Wasser | Siemens HLW 8 | 8.0 | 2020 | 231 | 4 | 2644.0 | 494.0 | 391.0 | 363.0 | 181.0 | 118.0 | 49.0 | 33.0 | 31.0 | 41.0 | 172.0 | 285.0 | 486.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
168 | Luft/Wasser | Siemens HLW 8 | 8.0 | 2019 | 231 | 4 | 2582.0 | 400.0 | 352.0 | 324.0 | 161.0 | 143.0 | 43.0 | 15.0 | 34.0 | 41.0 | 163.0 | 412.0 | 494.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
168 | Luft/Wasser | Siemens HLW 8 | 8.0 | 2018 | 231 | 4 | 3038.0 | 512.0 | 658.0 | 517.0 | 79.0 | 38.0 | 34.0 | 33.0 | 17.0 | 40.0 | 138.0 | 390.0 | 582.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
168 | Luft/Wasser | Siemens HLW 8 | 8.0 | 2017 | 231 | 4 | 3135.0 | 973.0 | 256.0 | 280.0 | 260.0 | 95.0 | 3.0 | 30.0 | 44.0 | 70.0 | 151.0 | 418.0 | 555.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
168 | Luft/Wasser | Siemens HLW 8 | 8.0 | 2016 | 231 | 3 | 3260.0 | 789.0 | 320.0 | 461.0 | 227.0 | 81.0 | 28.0 | 35.0 | 37.0 | 23.0 | 226.0 | 1033.0 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
168 | Luft/Wasser | Siemens HLW 8 | 8.0 | 2015 | 231 | 3 | 2999.0 | 633.0 | 569.0 | 429.0 | 173.0 | 61.0 | 79.0 | 37.0 | 37.0 | 66.0 | 250.0 | 298.0 | 367.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
168 | Luft/Wasser | Siemens HLW 8 | 8.0 | 2014 | 231 | 3 | 2473.0 | 496.0 | 484.0 | 197.0 | 81.0 | 28.0 | 50.0 | 36.0 | 35.0 | 33.0 | 102.0 | 313.0 | 618.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
168 | Luft/Wasser | Siemens HLW 8 | 8.0 | 2013 | 231 | 3 | 3714.0 | 721.0 | 653.0 | 472.0 | 287.0 | 206.0 | 54.0 | 32.0 | 30.0 | 72.0 | 170.0 | 482.0 | 535.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
168 | Luft/Wasser | Siemens HLW 8 | 8.0 | 2012 | 231 | 3 | 3264.0 | 744 | 638.0 | 247 | 659.0 | 255 | 251.0 | 102 | 252.0 | 96 | 42.0 | 13 | 46.0 | 14 | 34.0 | 10 | 23.0 | 7 | 54.0 | 212.0 | 467.0 | 586.0 | ||||||||||||||||||||||||||||||||||||||||||
168 | Luft/Wasser | Siemens HLW 8 | 8.0 | 2011 | 231 | 3 | 2871.0 | 1106 | 587.0 | 227 | 473.0 | 185 | 388.0 | 148 | 67.0 | 23 | 36.0 | 11 | 28.0 | 8 | 33.0 | 10 | 28.0 | 9 | 36.0 | 10 | 214.0 | 92 | 476.0 | 187 | 505.0 | 196 | ||||||||||||||||||||||||||||||||||||||
168 | Luft/Wasser | Siemens HLW 8 | 8.0 | 2010 | 231 | 2 | 3670.0 | 1395 | 770.0 | 365 | 625.0 | 182 | 430.0 | 142 | 148.0 | 55 | 120.0 | 44 | 34.0 | 9 | 19.0 | 6 | 23.0 | 12 | 39.0 | 11 | 195.0 | 75 | 437.0 | 167 | 830.0 | 327 | ||||||||||||||||||||||||||||||||||||||
168 | Luft/Wasser | Siemens HLW 8 | 8.0 | 2009 | 231 | 2 | 3236.0 | 271 | 805.0 | 580.0 | 453.0 | 76.0 | 64.0 | 40.0 | 31.0 | 27.0 | 35.0 | 183.0 | 282.0 | 660.0 | 271 | |||||||||||||||||||||||||||||||||||||||||||||||||
168 | Luft/Wasser | Siemens HLW 8 | 8.0 | 2008 | 231 | 2 | 1342.0 | 85.0 | 204.0 | 395.0 | 658.0 |
NR | 168 |
Username | kWh-Jäger |
Einbaujahr der WP | 2008-01-03 |
PLZ des Wohnortes | 47495 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Siemens HLW 8 |
modulierend | |
Leistung (0/35) | 8.0 kW |
berechneter Primärenergiebedarf | 38.2 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 43 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 2600 Watt DB |
elektr. Verbrauch HP gem./DB | 90 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 27.0 °C |
Spreizung Heizkr. | 9.0 |
Heizflaeche | 231 m² |
Lüftung | zenKWLWR |
Personen | 3 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Massives KFW-40 Haus aus Porenbeton 30 cm mit 14 cm 035-Dämmung,Dreischeibenverglasung, An=263,5 m². Stromverbrauch beinhaltet Heizung, Lüftung und WW incl. WP-Steuerung.FBH ohne Einzelraumregelung. |