| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 1696 | Luft/Wasser | Viessmann Vitocal 200-S 201.B07 | 5.6 | 2018 | 150 | 4 | 887.0 | 2880.0 | 3.25 | 438.0 | 1519.0 | 3.47 | 449.0 | 1361.0 | 3.03 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 1696 | Luft/Wasser | Viessmann Vitocal 200-S 201.B07 | 5.6 | 2017 | 150 | 4 | 1370.0 | 4292.0 | 320 | 3.13 | 516.0 | 1482.0 | 2.87 | 323.0 | 1040.0 | 3.22 | 274.0 | 916.0 | 320 | 3.34 | 257.0 | 854.0 | 3.32 | |||||||||||||||||||||||||||||||||||||||||||||||
| 1696 | Luft/Wasser | Viessmann Vitocal 200-S 201.B07 | 5.6 | 2016 | 150 | 4 | 2660.0 | 8458.3 | 2723 | 3.18 | 398.0 | 1203.0 | 419 | 3.02 | 397.0 | 1354.0 | 467 | 3.41 | 424.0 | 1399.0 | 494 | 3.30 | 259.0 | 850.0 | 208 | 3.28 | 71.0 | 232.0 | 56 | 3.27 | 27.0 | 83.0 | 23 | 3.07 | 27.0 | 82.0 | 13 | 3.04 | 51.0 | 142.7 | 15 | 2.80 | 79.0 | 225.6 | 27 | 2.86 | 160.0 | 448.0 | 113 | 2.80 | 299.0 | 953.0 | 392 | 3.19 | 468.0 | 1486.0 | 496 | 3.18 |
| NR | 1696 |
| Username | StefanJ |
| Einbaujahr der WP | 2013-11-01 |
| PLZ des Wohnortes | 72631 |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | Viessmann Vitocal 200-S 201.B07 |
| modulierend | |
| Leistung (0/35) | 5.6 kW |
| berechneter Primärenergiebedarf | 42.0 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 45 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | FBH |
| elektr. Verbrauch WP ohne NA gem./DB | 1730 Watt DB |
| elektr. Verbrauch HP gem./DB | 0 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | > erfasst: |
| WMZ | |
| Mittlere Raumtemp. | 22.0 °C |
| Mittlere Wärmequellentemperatur | 0.0 °C |
| Heizung max. Vorlauf Temp. | 0.0 °C |
| Spreizung Heizkr. | 2.0 |
| Heizflaeche | 150 m² |
| Lüftung | Fenster |
| Personen | 4 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen |