Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1782 | Luft/Wasser | IDM Terra ML 8 - 13 complete HGL | 8.2 | 2025 | 180 | 2 | 1890.4 | 6736.1 | 698 | 3.56 | 964.2 | 3456.9 | 358 | 3.59 | 926.2 | 3279.2 | 340 | 3.54 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
1782 | Luft/Wasser | IDM Terra ML 8 - 13 complete HGL | 8.2 | 2024 | 180 | 2 | 4662.4 | 16845.4 | 1691 | 3.66 | 1057.0 | 3468.8 | 355 | 3.28 | 565.0 | 2368.0 | 229 | 4.19 | 488.0 | 1819.1 | 172 | 3.73 | 316.0 | 1123.3 | 109 | 3.55 | 59.0 | 129.2 | 11 | 2.19 | 28.0 | 8.5 | 1 | 0.30 | 27.0 | 0 | 0 | 28.0 | 0 | 0 | 53.0 | 61.0 | 3 | 1.15 | 306.0 | 1260.1 | 113 | 4.12 | 774.0 | 3094.9 | 321 | 4.00 | 961.4 | 3512.5 | 377 | 3.65 | ||||||||||||||
1782 | Luft/Wasser | IDM Terra ML 8 - 13 complete HGL | 8.2 | 2023 | 180 | 2 | 4679.0 | 17291.2 | 1734 | 3.76 | 926.0 | 3413.5 | 352 | 3.69 | 814.0 | 2895.6 | 296 | 3.56 | 550.0 | 2055.8 | 201 | 3.74 | 464.0 | 1684.6 | 167 | 3.63 | 117.0 | 485.4 | 36 | 4.15 | 27.0 | 0 | 0 | 26.0 | 0 | 0 | 26.0 | 0 | 0 | 31.0 | 9.5 | 1 | 0.31 | 197.0 | 719.8 | 66 | 3.65 | 676.0 | 2670.1 | 270 | 3.95 | 825.0 | 3356.9 | 345 | 4.07 | |||||||||||||||
1782 | Luft/Wasser | IDM Terra ML 8 - 13 complete HGL | 8.2 | 2022 | 180 | 2 | 4932.0 | 17210.4 | 1698 | 3.55 | 1130.0 | 4081.7 | 371 | 3.61 | 688.0 | 2603.8 | 293 | 3.78 | 534.0 | 1789.7 | 166 | 3.35 | 355.0 | 1266.0 | 126 | 3.57 | 72.0 | 176.6 | 16 | 2.45 | 27.0 | 0 | 0 | 27.0 | 0 | 0 | 26.0 | 0 | 0 | 144.0 | 470.4 | 40 | 3.27 | 223.0 | 794.5 | 69 | 3.56 | 678.0 | 2338.7 | 231 | 3.45 | 1028.0 | 3689.0 | 386 | 3.59 | |||||||||||||||
1782 | Luft/Wasser | IDM Terra ML 8 - 13 complete HGL | 8.2 | 2021 | 180 | 2 | 5696.0 | 19915.0 | 2056 | 3.50 | 1125.0 | 3494.9 | 410 | 3.11 | 747.0 | 2571.0 | 263 | 3.44 | 682.0 | 2439.7 | 250 | 3.58 | 419.0 | 1433.3 | 141 | 3.42 | 264.0 | 972.7 | 89 | 3.68 | 32.0 | 10.5 | 1 | 0.33 | 37.0 | 26.9 | 1 | 0.73 | 39.0 | 40.1 | 3 | 1.03 | 34.0 | 11.4 | 1 | 0.34 | 368.0 | 1356.9 | 128 | 3.69 | 887.0 | 3507.1 | 354 | 3.95 | 1062.0 | 4050.5 | 415 | 3.81 | ||||||||||||
1782 | Luft/Wasser | IDM Terra ML 8 - 13 complete HGL | 8.2 | 2020 | 180 | 2 | 4723.0 | 16940.1 | 1714 | 3.59 | 978.0 | 3527.6 | 368 | 3.61 | 662.0 | 2561.3 | 258 | 3.87 | 554.0 | 1970.0 | 189 | 3.56 | 120.0 | 259.0 | 23 | 2.16 | 56.0 | 49.9 | 4 | 0.89 | 48.0 | 62.2 | 4 | 1.30 | 26.0 | 0.2 | 0 | 0.01 | 31.0 | 11.7 | 1 | 0.38 | 66.0 | 153.0 | 14 | 2.32 | 400.0 | 1666.0 | 155 | 4.17 | 703.0 | 2715.8 | 278 | 3.86 | 1079.0 | 3963.4 | 420 | 3.67 | ||||||||||||
1782 | Luft/Wasser | IDM Terra ML 8 - 13 complete HGL | 8.2 | 2019 | 180 | 2 | 5126.0 | 17629.5 | 1608 | 3.50 | 900.0 | 3000.0 | 280 | 3.33 | 900.0 | 3000.0 | 280 | 3.33 | 823.0 | 2816.9 | 190 | 3.42 | 242.0 | 745.0 | 67 | 3.08 | 201.0 | 642.5 | 57 | 3.20 | 26.0 | 0 | 0 | 28.0 | 0 | 0 | 28.0 | 0 | 0 | 50.0 | 54.5 | 4 | 1.09 | 297.0 | 1181.0 | 107 | 3.98 | 715.0 | 2842.2 | 285 | 3.98 | 916.0 | 3347.4 | 338 | 3.65 | |||||||||||||||
1782 | Luft/Wasser | IDM Terra ML 8 - 13 complete HGL | 8.2 | 2018 | 180 | 2 | 5052.0 | 17410.9 | 1725 | 3.52 | 844.0 | 3370.6 | 338 | 3.99 | 1202.0 | 3792.4 | 382 | 3.16 | 797.0 | 2828.7 | 276 | 3.55 | 147.0 | 502.4 | 48 | 3.42 | 28.0 | 0 | 0 | 26.0 | 0 | 0 | 27.0 | 0 | 0 | 27.0 | 0 | 0 | 39.0 | 22.6 | 2 | 0.58 | 218.0 | 760.9 | 74 | 3.49 | 755.0 | 2732.4 | 266 | 3.62 | 942.0 | 3400.9 | 339 | 3.61 | ||||||||||||||||
1782 | Luft/Wasser | IDM Terra ML 8 - 13 complete HGL | 8.2 | 2017 | 180 | 2 | 5570.0 | 19413.3 | 1951 | 3.54 | 1488.0 | 4507.9 | 487 | 3.03 | 786.0 | 2854.6 | 284 | 3.63 | 464.0 | 1781.6 | 167 | 3.84 | 419.0 | 1566.3 | 154 | 3.74 | 130.0 | 459.3 | 44 | 3.53 | 26.0 | 0 | 0 | 31.0 | 0 | 0 | 28.0 | 0 | 0 | 94.0 | 300.7 | 27 | 3.20 | 281.0 | 1090.7 | 102 | 3.88 | 784.0 | 3111.1 | 315 | 3.97 | 1039.0 | 3741.1 | 371 | 3.60 | |||||||||||||||
1782 | Luft/Wasser | IDM Terra ML 8 - 13 complete HGL | 8.2 | 2016 | 180 | 2 | 2963.0 | 10349.1 | 1057 | 3.58 | 407.6 | 1423.5 | 150 | 3.49 | 76.0 | 122.5 | 11 | 1.61 | 24.4 | 0 | 0 | 22.0 | 0 | 0 | 24.0 | 0 | 0 | 52.0 | 84.0 | 7 | 1.62 | 448.0 | 1720.0 | 159 | 3.84 | 802.0 | 3075.2 | 313 | 3.83 | 1107.0 | 3923.9 | 417 | 3.54 |
NR | 1782 |
Username | idmwäpu |
Einbaujahr der WP | 2016-03-21 |
PLZ des Wohnortes | 86672 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | IDM Terra ML 8 - 13 complete HGL |
modulierend | Ja |
Leistung (0/35) | 8.2 kW |
berechneter Primärenergiebedarf | 100.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 50 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 2040 Watt DB |
elektr. Verbrauch HP gem./DB | 35 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | intern |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 35.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 180 m² |
Lüftung | Fenster |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | Nein |
Bemerkungen | Freistehendes-EFH-Ziegel Bj.1986 mit Dachausbau, Heizungsanlage 2016 erneuert. Anlage mit 1000ltr Hygienik-Combi-Speicher. *** Solar-Thermi ab 15.12.2024 außer Betrieb (Bivalent bedeutet bei mir: kleine Wasser-Solar-Thermhermie für Brauchwasser auf dem Dach, wird über Wärmetauscher auch in den Hygienik-Speicher gespeist.) Stromverbrauch am Stromzähler ist inclusive des Eigenbedarfes für Steuerungen und Umwälzpumpen, auch für Solaranlage. Betriebsstunden und Wärmemenge sind aus der IDM-Wärmepumpen-Steuerung. |