Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1794 | Sole/Wasser | Alpha Innotec - WZSV 62H3M | 3.3 | 2023 | 216 | 4 | 1033.9 | 5253.6 | 5.08 | 271.1 | 1489.1 | 5.49 | 255.0 | 1355.0 | 5.31 | 236.8 | 1241.6 | 5.24 | 167.9 | 886.6 | 5.28 | 31.1 | 100.6 | 3.23 | 19.1 | 46.0 | 2.41 | 15.6 | 39.7 | 2.54 | 18.2 | 42.6 | 2.34 | 19.1 | 52.4 | 2.74 | ||||||||||||||||||||||||||||||||||
1794 | Sole/Wasser | Alpha Innotec - WZSV 62H3M | 3.3 | 2022 | 216 | 4 | 1570.4 | 8651.5 | 5.51 | 291.5 | 1610.8 | 5.53 | 260.7 | 1351.7 | 5.18 | 234.5 | 1292.5 | 5.51 | 149.9 | 725.3 | 4.84 | 29.4 | 83.8 | 2.85 | 16.0 | 37.1 | 2.32 | 20.0 | 42.9 | 2.15 | 16.1 | 34.7 | 2.16 | 35.6 | 195.4 | 5.49 | 79.2 | 524.7 | 6.63 | 137.5 | 957.4 | 6.96 | 300.0 | 1795.2 | 5.98 | |||||||||||||||||||||||||
1794 | Sole/Wasser | Alpha Innotec - WZSV 62H3M | 3.3 | 2021 | 216 | 4 | 1715.5 | 9413.3 | 5.49 | 311.8 | 1782.6 | 5.72 | 280.7 | 1400.4 | 4.99 | 248.9 | 1275.1 | 5.12 | 192.5 | 997.4 | 5.18 | 79.0 | 418.0 | 5.29 | 18.6 | 44.8 | 2.41 | 18.0 | 47.1 | 2.62 | 16.6 | 38.4 | 2.31 | 19.2 | 55.2 | 2.88 | 81.4 | 590.0 | 7.25 | 191.4 | 1218.5 | 6.37 | 257.4 | 1545.8 | 6.01 | |||||||||||||||||||||||||
1794 | Sole/Wasser | Alpha Innotec - WZSV 62H3M | 3.3 | 2020 | 216 | 4 | 1420.5 | 8570.6 | 6.03 | 255.7 | 1557.7 | 6.09 | 231.9 | 1366.1 | 5.89 | 216.2 | 1251.0 | 5.79 | 96.7 | 550.4 | 5.69 | 57.0 | 320.0 | 5.61 | 20.0 | 57.0 | 2.85 | 18.0 | 49.0 | 2.72 | 19.4 | 52.1 | 2.69 | 30.7 | 146.2 | 4.76 | 82.0 | 569.4 | 6.94 | 157.3 | 1107.4 | 7.04 | 235.6 | 1544.3 | 6.55 | |||||||||||||||||||||||||
1794 | Sole/Wasser | Alpha Innotec - WZSV 62H3M | 3.3 | 2019 | 216 | 4 | 1565.7 | 8712.9 | 5.56 | 298.1 | 1730.8 | 5.81 | 248.3 | 1332.0 | 5.36 | 226.2 | 1113.7 | 4.92 | 119.9 | 654.2 | 5.46 | 60.6 | 334.0 | 5.51 | 17.9 | 46.5 | 2.60 | 16.0 | 40.9 | 2.56 | 20.0 | 53.7 | 2.69 | 33.1 | 154.5 | 4.67 | 93.9 | 629.0 | 6.70 | 190.8 | 1116.8 | 5.85 | 240.9 | 1506.8 | 6.25 | |||||||||||||||||||||||||
1794 | Sole/Wasser | Alpha Innotec - WZSV 62H3M | 3.3 | 2018 | 216 | 4 | 1721.2 | 8724.3 | 5.07 | 305.7 | 1646.4 | 5.39 | 355.6 | 1734.6 | 4.88 | 356.1 | 1483.5 | 4.17 | 96.7 | 401.9 | 4.16 | 30.0 | 98.0 | 3.27 | 21.5 | 61.8 | 2.87 | 18.3 | 48.4 | 2.64 | 19.5 | 56.7 | 2.91 | 23.1 | 71.9 | 3.11 | 81.4 | 551.2 | 6.77 | 175.2 | 1137.6 | 6.49 | 238.1 | 1432.3 | 6.02 | |||||||||||||||||||||||||
1794 | Sole/Wasser | Alpha Innotec - WZSV 62H3M | 3.3 | 2017 | 216 | 4 | 1960.7 | 9451.7 | 4.82 | 338.4 | 1839.5 | 5.44 | 342.1 | 1523.7 | 4.45 | 269.8 | 1089.7 | 4.04 | 188.3 | 800.6 | 4.25 | 77.3 | 286.8 | 3.71 | 22.8 | 68.9 | 3.02 | 20.9 | 59.2 | 2.83 | 19.5 | 57.7 | 2.96 | 48.1 | 260.5 | 5.42 | 114.2 | 626.2 | 5.48 | 221.5 | 1206.7 | 5.45 | 297.8 | 1632.2 | 5.48 | |||||||||||||||||||||||||
1794 | Sole/Wasser | Alpha Innotec - WZSV 62H3M | 3.3 | 2016 | 216 | 4 | 2292.9 | 10706.3 | 4.67 | 539.0 | 2338.0 | 4.34 | 390.0 | 1735.0 | 4.45 | 360.2 | 1585.1 | 4.40 | 179.0 | 854.0 | 4.77 | 32.0 | 98.0 | 3.06 | 21.0 | 58.0 | 2.76 | 22.1 | 65.0 | 2.94 | 18.9 | 51.0 | 2.70 | 16.7 | 43.9 | 2.63 | 169.4 | 906.8 | 5.35 | 251.2 | 1405.1 | 5.59 | 293.4 | 1566.4 | 5.34 |
NR | 1794 |
Username | floriw2000 |
Einbaujahr der WP | 2015-11-20 |
PLZ des Wohnortes | 39167 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Alpha Innotec - WZSV 62H3M |
modulierend | Ja |
Leistung (0/35) | 3.3 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 47 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Grabenkollektor |
Tiefe | 2.0 m |
Fläche | 0 m² |
Heizungsart | FBH und Wandheizung |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | intern |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 0.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 216 m² |
Lüftung | zenKWLWR |
Personen | 4 |
Grabenkollektor Helfer | Ja |
Grabenkollektor Erfahrung | |
Bemerkungen | Da PV Anlage vorhanden, Nachtabsenkung. Tagsüber läuft die WP dann mit erhöhter Leistung und somit büße ich Effizienz ein. |