Verbrauchsdaten fuer Anlage Nr. 1795
| Jahr | Pers. | GESAMT | Jan | Feb | Mar | Apr | Mai | Jun | Jul | Aug | Sep | Okt | Nov | Dez | ||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | ||
| 2026 | 4 | 1505 | 4376 | 2.91 | 628 | 1589 | 2.53 | 476 | 1517 | 3.19 | 401 | 1270 | 3.17 | |||||||||||||||||||||||||||
| 2025 | 4 | 2922 | 7848 | 2.69 | 503 | 1421 | 2.83 | 546 | 1281 | 2.35 | 353 | 1157 | 3.28 | 155 | 437 | 2.82 | 71 | 131 | 1.85 | 29 | 40 | 1.38 | 49 | 83 | 1.69 | 39 | 55 | 1.41 | 69 | 141 | 2.04 | 215 | 694 | 3.23 | 345 | 944 | 2.74 | 548 | 1464 | 2.67 |
| 2024 | 4 | 2887 | 7388 | 2.56 | 543 | 1272 | 2.34 | 296 | 846 | 2.86 | 328 | 968 | 2.95 | 233 | 582 | 2.50 | 73 | 154 | 2.11 | 61 | 118 | 1.93 | 34 | 52 | 1.53 | 15 | 8 | 0.53 | 77 | 213 | 2.77 | 190 | 639 | 3.36 | 398 | 1041 | 2.62 | 639 | 1495 | 2.34 |
| 2023 | 4 | 2406 | 5939 | 2.47 | 412 | 916 | 2.22 | 377 | 919 | 2.44 | 338 | 928 | 2.75 | 253 | 741 | 2.93 | 65 | 107 | 1.65 | 13 | 8 | 0.62 | 26 | 30 | 1.15 | 25 | 30 | 1.20 | 42 | 73 | 1.74 | 89 | 176 | 1.98 | 357 | 939 | 2.63 | 409 | 1072 | 2.62 |
| 2022 | 4 | 2869 | 8202 | 2.86 | 687 | 2084 | 3.03 | 602 | 1627 | 2.70 | 352 | 1486 | 4.22 | 324 | 1070 | 3.30 | 91 | 209 | 2.30 | 52 | 100 | 1.92 | 48 | 88 | 1.83 | 42 | 72 | 1.71 | 109 | 340 | 3.12 | 103 | 242 | 2.35 | 131 | 266 | 2.03 | 328 | 618 | 1.88 |
| 2021 | 4 | 3724 | 12007 | 3.22 | 742 | 2220 | 2.99 | 481 | 1549 | 3.22 | 450 | 1482 | 3.29 | 328 | 1158 | 3.53 | 166 | 661 | 3.98 | 42 | 96 | 2.29 | 37 | 72 | 1.95 | 35 | 52 | 1.49 | 78 | 241 | 3.09 | 243 | 857 | 3.53 | 495 | 1610 | 3.25 | 627 | 2009 | 3.20 |
| 2020 | 4 | 3238 | 10986 | 3.39 | 635 | 2188 | 3.45 | 339 | 1228 | 3.62 | 462 | 1566 | 3.39 | 182 | 666 | 3.66 | 145 | 455 | 3.14 | 56 | 156 | 2.79 | 34 | 51 | 1.50 | 28 | 34 | 1.21 | 87 | 268 | 3.08 | 249 | 971 | 3.90 | 408 | 1436 | 3.52 | 613 | 1967 | 3.21 |
| 2019 | 4 | 3627 | 11927 | 3.29 | 815 | 2299 | 2.82 | 524 | 1587 | 3.03 | 386 | 1337 | 3.46 | 304 | 1125 | 3.70 | 237 | 929 | 3.92 | 19 | 14 | 0.74 | 33 | 67 | 2.03 | 32 | 63 | 1.97 | 83 | 308 | 3.71 | 200 | 757 | 3.79 | 442 | 1577 | 3.57 | 552 | 1864 | 3.38 |
| 2018 | 4 | 3514 | 11164 | 3.18 | 568 | 1852 | 3.26 | 780 | 2191 | 2.81 | 544 | 1842 | 3.39 | 153 | 630 | 4.12 | 54 | 182 | 3.37 | 25 | 32 | 1.28 | 24 | 23 | 0.96 | 18 | 4 | 0.22 | 57 | 146 | 2.56 | 219 | 825 | 3.77 | 464 | 1523 | 3.28 | 608 | 1914 | 3.15 |
| 2017 | 4 | 4248 | 13217 | 3.11 | 1068 | 2808 | 2.63 | 541 | 1732 | 3.20 | 398 | 1463 | 3.68 | 352 | 1194 | 3.39 | 165 | 595 | 3.61 | 39 | 54 | 1.38 | 30 | 51 | 1.70 | 50 | 110 | 2.20 | 167 | 632 | 3.78 | 227 | 838 | 3.69 | 499 | 1630 | 3.27 | 712 | 2110 | 2.96 |
| 2016 | 4 | 5237 | 7219 | 1.38 | 1063 | 656 | 623 | 438 | 253 | 723 | 2.86 | 103 | 282 | 2.74 | 115 | 279 | 2.43 | 90 | 209 | 2.32 | 154 | 393 | 2.55 | 353 | 1145 | 3.24 | 608 | 1898 | 3.12 | 781 | 2290 | 2.93 | ||||||||
| 2015 | 4 | 2660 | 0 | 124 | 199 | 323 | 577 | 768 | 669 | |||||||||||||||||||||||||||||||
Vollständige Anlagendetails
Allgemeine Daten
Anlagen Nr.
1795
Username
Starscream
Gebäude Daten
PLZ
87733
Heizfläche (m²)
145
Wärmeübertragung
FBH
Raumtemperatur (°C)
21.0
Lüftung
dezKWLWR
Endenergiebedarf (kWh/m²/anno)
67.5
berechnet nach Norm
EnEV2009
Wärmepumpe Daten
Hersteller / Typ
Hoval Belaria SRM 8
Bauart
Luft/Wasser
Heizleistung (kW) (0/35 2/35)
5.8
Betriebsart Mono/Bi/Tri-valent
Bi
Modulierend
Ja
Einbaudatum
2015-05-01
Wärmepumpe Leistungsaufnahme (W)
Umwälzpumpe Leistungsaufnahme (W)
Wärme Quelle & Senke
Quelle
Luft
Tiefe (m)
Fläche (m²)
max. Vorlauftemperatur (°C)
35.0
Spreizung Heizkreise (°K)
5.0
Quellenpumpe Leistungsaufnahme (W)
RGK Helfer
Nein
RGK Erfahrung
Warmwasser
über WP erzeugt
Ja
über WMZ erfasst
Ja
Temp (°C)
46
Legionellenschaltung
Nein
Zähler
Stromzähler
extern_geeicht
Stromzähler erfasst
Kompressor,Steuerung,Pumpen
Wärmemengenzähler
extern_geeicht
Informationen
Bemerkungen
Seit 01.01.2017 zusätzlich eine PV-Thermie Anlage mit 2.4KW zur Brauchwassererwärmung mittels Heizstab (Refusol PV-Heater).
Seit 01.10.2022 Schwedenofen im Wohn/Essbereich.
Links