Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1838 | Sole/Wasser | Nibe F1155-6 | 6.0 | 2020 | 227 | 6 | 3358.0 | 22331.0 | 5016 | 6.65 | 604.0 | 2969.0 | 734 | 4.92 | 569.0 | 2779.0 | 700 | 4.88 | 450.0 | 2584.0 | 614 | 5.74 | 195.0 | 1716.0 | 411 | 8.80 | 158.0 | 1640.0 | 297 | 10.38 | 56.0 | 962.0 | 78 | 17.18 | 66.0 | 812.0 | 94 | 12.30 | 40.0 | 1075.0 | 39 | 26.88 | 82.0 | 1009.0 | 181 | 12.30 | 205.0 | 1498.0 | 485 | 7.31 | 362.0 | 2221.0 | 645 | 6.14 | 571.0 | 3066.0 | 738 | 5.37 | ||||||||||||
1838 | Sole/Wasser | Nibe F1155-6 | 6.0 | 2019 | 227 | 5 | 3466.0 | 21423.0 | 5139 | 6.18 | 697.0 | 3369.0 | 739 | 4.83 | 536.0 | 2615.0 | 666 | 4.88 | 468.0 | 3054.0 | 665 | 6.53 | 247.0 | 2021.0 | 468 | 8.18 | 176.0 | 1544.0 | 355 | 8.77 | 32.0 | 451.0 | 8 | 14.09 | 44.0 | 512.0 | 7 | 11.64 | 50.0 | 672.0 | 70 | 13.44 | 89.0 | 790.0 | 180 | 8.88 | 216.0 | 1434.0 | 542 | 6.64 | 398.0 | 2280.0 | 707 | 5.73 | 513.0 | 2681.0 | 732 | 5.23 | ||||||||||||
1838 | Sole/Wasser | Nibe F1155-6 | 6.0 | 2018 | 227 | 5 | 3353.0 | 20215.0 | 4419 | 6.03 | 602.0 | 2934.0 | 747 | 4.87 | 658.0 | 3066.0 | 662 | 4.66 | 646.0 | 3088.0 | 702 | 4.78 | 289.0 | 2153.0 | 476 | 7.45 | 56.0 | 1319.0 | 67 | 23.55 | 32.0 | 534.0 | 17 | 16.69 | 28.0 | 377.0 | 13.46 | 26.0 | 219.0 | 8.42 | 40.0 | 499.0 | 41 | 12.48 | 125.0 | 1082.0 | 322 | 8.66 | 340.0 | 2137.0 | 662 | 6.29 | 511.0 | 2807.0 | 723 | 5.49 | ||||||||||||||
1838 | Sole/Wasser | Nibe F1155-6 | 6.0 | 2017 | 227 | 5 | 3236.0 | 20746.0 | 4790 | 6.41 | 671.0 | 3077.0 | 735 | 4.59 | 605.0 | 2784.0 | 688 | 4.60 | 378.0 | 2410.0 | 589 | 6.38 | 254.0 | 2183.0 | 489 | 8.59 | 114.0 | 1708.0 | 250 | 14.98 | 32.0 | 714.0 | 17 | 22.31 | 40.0 | 704.0 | 40 | 17.60 | 36.0 | 627.0 | 26 | 17.42 | 73.0 | 624.0 | 139 | 8.55 | 152.0 | 1029.0 | 391 | 6.77 | 334.0 | 2055.0 | 686 | 6.15 | 547.0 | 2831.0 | 740 | 5.18 | ||||||||||||
1838 | Sole/Wasser | Nibe F1155-6 | 6.0 | 2016 | 227 | 5 | 864.0 | 5047.6 | 1417 | 5.84 | 408.0 | 2565.0 | 677 | 6.29 | 456.0 | 2482.6 | 740 | 5.44 |
NR | 1838 |
Username | radis |
Einbaujahr | 2016-07-01 |
PLZ des Wohnortes | 24253 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Bi |
Hersteller Typ | Nibe F1155-6 |
modulierend | Ja |
Leistung (0/35) | 6.0 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 46 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Grabenkollektor |
Tiefe | 2.4 m |
Fläche | 0 m² |
Heizungsart | FBH und Radiatoren |
elektr. Verbrauch WP ohne NA gem./DB | 670 Watt DB |
elektr. Verbrauch HP gem./DB | 2 Watt |
elektr. Verbrauch WQ P gem./DB | 10 Watt |
Mittlere Raumtemp. | 22 °C |
Mittlere Wärmequellentemperatur | 3.0 °C |
Heizung max. Vorlauf Temp. | 38.0 °C |
Spreizung Heizkr. | 10.0 |
Heizflaeche | 227 m² |
Lüftung | zenKWL |
Personen | 5 |
Grabenkollektor Helfer | Ja |
Grabenkollektor Erfahrung | keine |
Bemerkungen | Ringgraben 1 Rohr 40*3,7 400m Solarthermie 10m² in WP eingebunden. Erzielte Werte sind incl. aller Pumpen und Software und Solarthermie (SJAZ) Die Anlage ist unter www.rainerhome.de einsehbar.Dabei unter Benutzer und Passwort je ein g eingeben. Seit 2018 zähle ich beim Ertrag der Solarthermie pauschal weniger: Apr. und Sept: -10% Mai-Augus: -20% Das mache ich, um die nicht unerheblichen Verluste des Pufferspeichers zu berücksichtigen. |