Verbrauchsdaten für Anlage Nr. 1838
| Jahr | Pers. | GESAMT | Jan | Feb | Mär | Apr | Mai | Jun | Jul | Aug | Sep | Okt | Nov | Dez | ||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | ||
| 2026 | 7 | 2283 | 9901 | 4.34 | 1023 | 4229 | 4.13 | 749 | 3151 | 4.21 | 511 | 2521 | 4.93 | |||||||||||||||||||||||||||
| 2025 | 7 | 4541 | 24047 | 5.30 | 730 | 3483 | 4.77 | 657 | 2993 | 4.56 | 568 | 2683 | 4.72 | 378 | 1922 | 5.08 | 325 | 1713 | 5.27 | 165 | 994 | 6.02 | 108 | 694 | 6.43 | 151 | 765 | 5.07 | 124 | 1257 | 10.14 | 323 | 2068 | 6.40 | 473 | 2690 | 5.69 | 539 | 2785 | 5.17 |
| 2024 | 7 | 3998 | 21852 | 5.47 | 684 | 3339 | 4.88 | 522 | 2635 | 5.05 | 495 | 2550 | 5.15 | 385 | 2067 | 5.37 | 203 | 1100 | 5.42 | 148 | 905 | 6.11 | 110 | 702 | 6.38 | 102 | 578 | 5.67 | 105 | 905 | 8.62 | 254 | 1601 | 6.30 | 450 | 2581 | 5.74 | 540 | 2889 | 5.35 |
| 2023 | 6 | 3825 | 20587 | 5.38 | 476 | 2571 | 5.40 | 493 | 2505 | 5.08 | 485 | 2412 | 4.97 | 386 | 2053 | 5.32 | 248 | 1365 | 5.50 | 123 | 648 | 5.27 | 105 | 595 | 5.67 | 106 | 646 | 6.09 | 94 | 555 | 5.90 | 231 | 1501 | 6.50 | 495 | 2698 | 5.45 | 583 | 3038 | 5.21 |
| 2022 | 6 | 3958 | 21395 | 5.41 | 604 | 2991 | 4.95 | 513 | 2570 | 5.01 | 498 | 2766 | 5.55 | 427 | 1908 | 4.47 | 244 | 1392 | 5.70 | 189 | 1067 | 5.65 | 119 | 689 | 5.79 | 121 | 846 | 6.99 | 121 | 785 | 6.49 | 224 | 1399 | 6.25 | 336 | 2037 | 6.06 | 562 | 2945 | 5.24 |
| 2021 | 6 | 4045 | 22380 | 5.53 | 704 | 3395 | 4.82 | 676 | 3059 | 4.53 | 528 | 2726 | 5.16 | 346 | 2133 | 6.16 | 238 | 1538 | 6.46 | 40 | 642 | 16.05 | 44 | 537 | 12.20 | 74 | 533 | 7.20 | 117 | 813 | 6.95 | 228 | 1536 | 6.74 | 430 | 2314 | 5.38 | 620 | 3154 | 5.09 |
| 2020 | 6 | 3358 | 22331 | 6.65 | 604 | 2969 | 4.92 | 569 | 2779 | 4.88 | 450 | 2584 | 5.74 | 195 | 1716 | 8.80 | 158 | 1640 | 10.38 | 56 | 962 | 17.18 | 66 | 812 | 12.30 | 40 | 1075 | 26.88 | 82 | 1009 | 12.30 | 205 | 1498 | 7.31 | 362 | 2221 | 6.14 | 571 | 3066 | 5.37 |
| 2019 | 5 | 3466 | 21423 | 6.18 | 697 | 3369 | 4.83 | 536 | 2615 | 4.88 | 468 | 3054 | 6.53 | 247 | 2021 | 8.18 | 176 | 1544 | 8.77 | 32 | 451 | 14.09 | 44 | 512 | 11.64 | 50 | 672 | 13.44 | 89 | 790 | 8.88 | 216 | 1434 | 6.64 | 398 | 2280 | 5.73 | 513 | 2681 | 5.23 |
| 2018 | 5 | 3353 | 20215 | 6.03 | 602 | 2934 | 4.87 | 658 | 3066 | 4.66 | 646 | 3088 | 4.78 | 289 | 2153 | 7.45 | 56 | 1319 | 23.55 | 32 | 534 | 16.69 | 28 | 377 | 13.46 | 26 | 219 | 8.42 | 40 | 499 | 12.47 | 125 | 1082 | 8.66 | 340 | 2137 | 6.29 | 511 | 2807 | 5.49 |
| 2017 | 5 | 3236 | 20746 | 6.41 | 671 | 3077 | 4.59 | 605 | 2784 | 4.60 | 378 | 2410 | 6.38 | 254 | 2183 | 8.59 | 114 | 1708 | 14.98 | 32 | 714 | 22.31 | 40 | 704 | 17.60 | 36 | 627 | 17.42 | 73 | 624 | 8.55 | 152 | 1029 | 6.77 | 334 | 2055 | 6.15 | 547 | 2831 | 5.18 |
| 2016 | 5 | 864 | 5048 | 5.84 | 408 | 2565 | 6.29 | 456 | 2483 | 5.44 | ||||||||||||||||||||||||||||||
| 0 | 730 | 3483 | 4.77 | 730 | 3483 | 4.77 | ||||||||||||||||||||||||||||||||||
Vollständige Anlagendetails
Allgemeine Daten
Anlagen Nr.
1838
Username
radis
Gebäude Daten
PLZ
24253
Heizfläche (m²)
227
Wärmeübertragung
FBH und Radiatoren
Raumtemperatur (°C)
22.0
Lüftung
zenKWL
Endenergiebedarf (kWh/m²/anno)
berechnet nach Norm
Wärmepumpe Daten
Hersteller / Typ
Nibe F1155-6
Bauart
Sole/Wasser
Heizleistung (kW) (0/35 2/35)
6.0
Betriebsart Mono/Bi/Tri-valent
Mono
Modulierend
Ja
Einbaudatum
2016-07-01
Wärmepumpe Leistungsaufnahme (W)
670 DB
Umwälzpumpe Leistungsaufnahme (W)
2 DB
Wärme Quelle & Senke
Quelle
Grabenkollektor
Tiefe (m)
2.4
Fläche (m²)
max. Vorlauftemperatur (°C)
38.0
Spreizung Heizkreise (°K)
10.0
Quellenpumpe Leistungsaufnahme (W)
10 DB
RGK Helfer
Ja
RGK Erfahrung
keine
Warmwasser
über WP erzeugt
Ja
über WMZ erfasst
Ja
Temp (°C)
46
Legionellenschaltung
Nein
Zähler
Stromzähler
extern
Stromzähler erfasst
Kompressor,Steuerung,Pumpen
Wärmemengenzähler
extern
Informationen
Bemerkungen
Ringgraben 1 Rohr 40*3,7 400m
Besser wären 2 Rohre a`32mm gewesen (weniger Pumpenleisung, Redundanz)
Seit 9.2021 KEINE ST mehr!
Links
http://4ccshdlih1b0q5kq.myfritz.net/GRAFIK.htm