Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1907 | Sole/Wasser | Nibe F1155-12 | 5.0 | 2022 | 164 | 5 | 2379.0 | 11581.1 | 3761 | 4.87 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 2379.0 | 11581.1 | 3761 | 4.87 | |||||||||||||||||||||||
1907 | Sole/Wasser | Nibe F1155-12 | 5.0 | 2021 | 164 | 5 | 2624.0 | 13053.6 | 4295 | 4.97 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 2624.0 | 13053.6 | 4295 | 4.97 | |||||||||||||||||||||||
1907 | Sole/Wasser | Nibe F1155-12 | 5.0 | 2020 | 164 | 5 | 2213.9 | 11561.8 | 3786 | 5.22 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1216.0 | 6157.0 | 2051 | 5.06 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 997.9 | 5404.8 | 1735 | 5.42 | ||||||||||||||||||||||
1907 | Sole/Wasser | Nibe F1155-12 | 5.0 | 2019 | 164 | 6 | 2403.4 | 12021.7 | 3879 | 5.00 | 263.0 | 1286.0 | 444 | 4.89 | 438.9 | 1991.7 | 608 | 4.54 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 840.5 | 4171.0 | 1339 | 4.96 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 861.0 | 4573.0 | 1488 | 5.31 | ||||||||||||||||||||
1907 | Sole/Wasser | Nibe F1155-12 | 5.0 | 2018 | 164 | 5 | 2267.5 | 11230.8 | 3582 | 4.95 | 418.0 | 2020.3 | 716 | 4.83 | 479.0 | 2045.0 | 569 | 4.27 | 204.0 | 1824.0 | 610 | 8.94 | 210.0 | 708.0 | 235 | 3.37 | 150.0 | 262.8 | 72 | 1.75 | 23.0 | 114.6 | 19 | 4.98 | 19.2 | 95.8 | 12 | 4.99 | 21.3 | 109.3 | 13 | 5.13 | 56.0 | 380.7 | 111 | 6.80 | 102.0 | 627.0 | 197 | 6.15 | 304.0 | 1636.0 | 547 | 5.38 | 281.0 | 1407.3 | 481 | 5.01 | ||||||||||||
1907 | Sole/Wasser | Nibe F1155-12 | 5.0 | 2017 | 164 | 5 | 2438.7 | 12128.3 | 4001 | 4.97 | 550.0 | 2379.6 | 734 | 4.33 | 409.1 | 1813.8 | 669 | 4.43 | 254.2 | 1248.6 | 453 | 4.91 | 279.4 | 1420.7 | 491 | 5.08 | 61.6 | 356.8 | 102 | 5.79 | 24.7 | 133.5 | 25 | 5.40 | 21.6 | 118.2 | 22 | 5.47 | 28.6 | 161.1 | 33 | 5.63 | 70.5 | 483.0 | 131 | 6.85 | 112.0 | 743.0 | 213 | 6.63 | 269.0 | 1510.0 | 510 | 5.61 | 358.0 | 1760.0 | 618 | 4.92 | ||||||||||||
1907 | Sole/Wasser | Nibe F1155-12 | 5.0 | 2016 | 164 | 4 | 472.6 | 2303.0 | 732 | 4.87 | 88.2 | 430.0 | 97 | 4.88 | 384.4 | 1873.0 | 635 | 4.87 |
NR | 1907 |
Username | platsch |
Einbaujahr der WP | 2016-11-25 |
PLZ des Wohnortes | 50999 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Nibe F1155-12 |
modulierend | Ja |
Leistung (0/35) | 5.0 kW |
berechneter Primärenergiebedarf | 70.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 46 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Grabenkollektor |
Tiefe | 0.8 m |
Fläche | 100 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 1 Watt DB |
elektr. Verbrauch HP gem./DB | 60 Watt |
elektr. Verbrauch WQ P gem./DB | 180 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 5.0 °C |
Heizung max. Vorlauf Temp. | 35.0 °C |
Spreizung Heizkr. | 4.2 |
Heizflaeche | 164 m² |
Lüftung | Fenster |
Personen | 5 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | keine |
Bemerkungen | Nachfolge-Pumpe zur Redmannpumpe siehe : Alte Anlage |