Verbrauchsdaten für Anlage Nr. 1975

JahrPers. GESAMT JanFebMärAprMaiJun JulAugSepOktNovDez
StromWMZAZStromWMZAZStromWMZAZStromWMZAZStromWMZAZStromWMZAZStromWMZAZStromWMZAZStromWMZAZStromWMZAZStromWMZAZStromWMZAZStromWMZAZ
2022 5 1086 4520 4.16 31013054.2125010364.1430212554.162249244.12
2021 5 2142 10062 4.70 32116535.1529314775.0430915805.111889665.141256074.85381534.03401624.05552554.641053913.731626724.142078984.3429912484.17
2020 5 1918 9420 4.91 28414815.212339974.2827914165.081276274.941537254.74512074.09672774.1624933.88642814.401387235.2521911425.2228014525.18
2019 5 1887 8112 4.30 34314134.1224410224.182279444.161676784.061395513.9632922.8632912.81411202.93712623.671465964.0820510705.2223812735.34
2018 5 2064 8165 3.96 27911844.2435414354.0633313394.021324993.79621873.02621863.00411092.64491312.68672383.581516304.172399964.1729712314.15
2017 4 2124 8460 3.98 39915673.9327711414.122279494.181988244.16963513.66511382.71481302.71481292.67963703.851355444.0324210314.2630712864.19
2016 4 609 2422 3.98 26710173.8134214054.11

Vollständige Anlagendetails

Allgemeine Daten
Anlagen Nr.
1975
Username
katerlysator
Gebäude Daten
PLZ
01844
Heizfläche (m²)
113
Wärmeübertragung
FBH
Raumtemperatur (°C)
Lüftung
zenKWL
Endenergiebedarf (kWh/m²/anno)
berechnet nach Norm
Wärmepumpe Daten
Hersteller / Typ
Vaillant geoTHERM plus 82/3
Bauart
Sole/Wasser
Heizleistung (kW) (0/35 2/35)
7.8
Betriebsart Mono/Bi/Tri-valent
Mono
Modulierend
Nein
Einbaudatum
2013-08-22
Wärmepumpe Leistungsaufnahme (W)
Umwälzpumpe Leistungsaufnahme (W)
Wärme Quelle & Senke
Quelle
2 Erdbohrungen a
Tiefe (m)
60.0
Fläche (m²)
max. Vorlauftemperatur (°C)
Spreizung Heizkreise (°K)
Quellenpumpe Leistungsaufnahme (W)
RGK Helfer
Nein
RGK Erfahrung
Warmwasser
über WP erzeugt
Ja
über WMZ erfasst
Ja
Temp (°C)
47
Legionellenschaltung
Nein
Zähler
Stromzähler
extern_geeicht
Stromzähler erfasst
Wärmemengenzähler
intern
Informationen
Bemerkungen
Links

Standort