| Jahr | Pers. | GESAMT | Jan | Feb | Mar | Apr | Mai | Jun | Jul | Aug | Sep | Okt | Nov | Dez | ||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | ||
| 2026 | 4 | 2570 | * 14018 | 5.45 | 271 | 1578 | 5.84 | 241 | 1435 | 5.96 | 408 | 2237 | 5.49 | 484 | 2601 | 5.38 | 586 | 3091 | 5.28 | 582 | 3075 | 5.28 | ||||||||||||||||||
| 2025 | 4 | 4891 | * 26836 | 5.49 | 252 | 1489 | 5.91 | 281 | 1630 | 5.80 | 420 | 2296 | 5.47 | 512 | 2738 | 5.35 | 543 | 2887 | 5.31 | 544 | 2891 | 5.31 | 521 | 2782 | 5.34 | 558 | 2961 | 5.30 | 423 | 2312 | 5.46 | 395 | 2178 | 5.51 | 246 | 1461 | 5.94 | 194 | 1213 | 6.24 |
| 2024 | 4 | 4866 | * 26865 | 5.52 | 150 | 1000 | 6.67 | 287 | 1660 | 5.78 | 297 | 1708 | 5.75 | 521 | 2782 | 5.34 | 520 | 2778 | 5.34 | 606 | 3188 | 5.26 | 611 | 3214 | 5.26 | 619 | 3253 | 5.25 | 445 | 2417 | 5.43 | 336 | 2039 | 6.06 | 277 | 1610 | 5.81 | 195 | 1217 | 6.24 |
| 2023 | 4 | 5097 | * 27337 | 5.36 | 161 | 1039 | 6.43 | 303 | 1706 | 5.62 | 398 | 2151 | 5.40 | 521 | 2729 | 5.24 | 556 | 2895 | 5.20 | 634 | 3259 | 5.14 | 641 | 3291 | 5.14 | 502 | 2642 | 5.26 | 527 | 2758 | 5.23 | 436 | 2331 | 5.34 | 228 | 1350 | 5.93 | 189 | 1186 | 6.28 |
| 2022 | 4 | 5132 | * 27480 | 5.35 | 281 | 1599 | 5.70 | 395 | 2136 | 5.41 | 486 | 2566 | 5.28 | 486 | 2562 | 5.28 | 563 | 2927 | 5.20 | 592 | 3061 | 5.17 | 496 | 2610 | 5.26 | 513 | 2693 | 5.25 | 484 | 2553 | 5.28 | 387 | 2101 | 5.42 | 332 | 1841 | 5.54 | 117 | 832 | 7.09 |
| 2021 | 4 | 5029 | * 27009 | 5.37 | 94 | 733 | 7.77 | 290 | 1641 | 5.67 | 412 | 2215 | 5.38 | 526 | 2753 | 5.23 | 569 | 2952 | 5.19 | 599 | 3093 | 5.17 | 564 | 2931 | 5.20 | 550 | 2867 | 5.21 | 525 | 2747 | 5.23 | 449 | 2391 | 5.32 | 257 | 1487 | 5.79 | 196 | 1200 | 6.13 |
| 2020 | 4 | 5145 | * 28222 | 5.49 | 302 | 1760 | 5.83 | 369 | 2090 | 5.66 | 417 | 2324 | 5.57 | 551 | 2980 | 5.41 | 528 | 2817 | 5.33 | 517 | 2762 | 5.34 | 558 | 2959 | 5.30 | 516 | 2756 | 5.34 | 457 | 2476 | 5.41 | 386 | 2132 | 5.53 | 347 | 1943 | 5.61 | 197 | 1223 | 6.23 |
| 2019 | 4 | 3782 | * 21562 | 5.70 | 171 | 1101 | 6.44 | 377 | 2089 | 5.54 | 445 | 2461 | 5.53 | 454 | 2504 | 5.52 | 466 | 2565 | 5.50 | 494 | 2700 | 5.47 | 137 | 952 | 6.94 | 319 | 1842 | 5.78 | 381 | 2149 | 5.63 | 278 | 1641 | 5.91 | 260 | 1557 | 5.99 | |||
| 2018 | 4 | 4383 | * 24500 | 5.59 | 255 | 1503 | 5.90 | 145 | 990 | 6.83 | 353 | 2012 | 5.69 | 492 | 2692 | 5.47 | 453 | 2456 | 5.42 | 456 | 2471 | 5.41 | 463 | 2503 | 5.40 | 459 | 2484 | 5.41 | 449 | 2434 | 5.42 | 392 | 2160 | 5.52 | 281 | 1627 | 5.80 | 185 | 1168 | 6.31 |
| 2017 | 4 | 3652 | * 15954 | 4.37 | 54 | 129 | 604 | 504 | 2650 | 5.26 | 315 | 1761 | 5.59 | 268 | 1540 | 5.75 | 293 | 1659 | 5.66 | 377 | 2053 | 5.45 | 377 | 2053 | 5.45 | 400 | 2121 | 5.30 | 190 | 1172 | 6.17 | 141 | 945 | 6.70 | ||||||
Vollständige Anlagendetails
Allgemeine Daten
Anlagen Nr.
2017
Username
izapper
Gebäude Daten
PLZ
87600
Heizfläche (m²)
603
Wärmeübertragung
FBH
Raumtemperatur (°C)
18.0
Lüftung
zenKWLWR
Endenergiebedarf (kWh/m²/anno)
45.0
berechnet nach Norm
EnEV2014
Wärmepumpe Daten
Hersteller / Typ
Viessmann Vitocal 300-g bwc 301-b17
Bauart
Sole/Wasser
Heizleistung (kW) (0/35 2/35)
17.2
Betriebsart Mono/Bi/Tri-valent
Mono
Modulierend
Ja
Einbaudatum
2016-12-21
Wärmepumpe Leistungsaufnahme (W)
800 gem.
Umwälzpumpe Leistungsaufnahme (W)
100 DB
Wärme Quelle & Senke
Quelle
x Erdbohrungen a
Tiefe (m)
95.0
Fläche (m²)
max. Vorlauftemperatur (°C)
35.0
Spreizung Heizkreise (°K)
7.0
Quellenpumpe Leistungsaufnahme (W)
50 DB
RGK Helfer
Nein
RGK Erfahrung
Warmwasser
über WP erzeugt
Ja
über WMZ erfasst
Nein
Temp (°C)
50
Legionellenschaltung
Ja
Zähler
Stromzähler
intern
Stromzähler erfasst
Kompressor,Steuerung,Pumpen
Wärmemengenzähler
intern
Informationen
Bemerkungen
3 Bohrungen á 95m Tiefe, Abstand mind 6m zueinander, Wärmepumpe in Betrieb seit Dezember 2016, Estrichheizung nicht mit Wärmepumpe, sondern mit separatem Heizgerät (Sunnyboy) durchgeführt. Fußbodenheizung Westtrakt, Deckenheizung Osttrakt.
Bem: Im Zeitraum 31.07.2019-15.09.2019: Falsche Messwerte! Grund: Onlineportal zeigte lückenhaft an, wurde korrigiert: Modul Spree erneuert läuft wieder einwandfrei.