Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2024 | Sole/Wasser | Novelan - SICV 6.2H3 | 6.3 | 2022 | 185 | 6 | 326.2 | 1891.1 | 706 | 5.80 | 326.2 | 1891.1 | 706 | 5.80 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2024 | Sole/Wasser | Novelan - SICV 6.2H3 | 6.3 | 2021 | 185 | 6 | 2373.0 | 13054.0 | 4888 | 5.50 | 365.3 | 1986.2 | 732 | 5.44 | 295.2 | 1453.8 | 570 | 4.92 | 330.2 | 1638.6 | 655 | 4.96 | 255.1 | 1324.5 | 353 | 5.19 | 156.0 | 862.2 | 353 | 5.53 | 55.6 | 253.6 | 65 | 4.56 | 41.6 | 212.4 | 53 | 5.11 | 33.1 | 170.5 | 44 | 5.15 | 63.5 | 398.6 | 123 | 6.28 | 161.3 | 1117.1 | 439 | 6.93 | 274.3 | 1737.8 | 720 | 6.34 | 341.8 | 1898.7 | 781 | 5.56 | ||||||||||||
2024 | Sole/Wasser | Novelan - SICV 6.2H3 | 6.3 | 2020 | 185 | 6 | 1988.0 | 10879.3 | 4194 | 5.47 | 312.6 | 1645.9 | 669 | 5.27 | 254.0 | 1352.3 | 589 | 5.32 | 269.7 | 1395.4 | 580 | 5.17 | 126.8 | 602.3 | 199 | 4.75 | 103.6 | 523.9 | 178 | 5.06 | 63.3 | 300.0 | 75 | 4.74 | 52.0 | 261.5 | 66 | 5.03 | 33.1 | 170.2 | 44 | 5.14 | 67.4 | 412.9 | 128 | 6.13 | 150.5 | 1034.7 | 410 | 6.88 | 220.7 | 1407.4 | 573 | 6.38 | 334.3 | 1772.8 | 683 | 5.30 | ||||||||||||
2024 | Sole/Wasser | Novelan - SICV 6.2H3 | 6.3 | 2019 | 185 | 6 | 2047.5 | 11005.3 | 4278 | 5.37 | 367.1 | 1880.1 | 728 | 5.12 | 278.2 | 1355.6 | 569 | 4.87 | 248.1 | 1255.0 | 551 | 5.06 | 168.2 | 873.0 | 355 | 5.19 | 156.4 | 824.9 | 310 | 5.27 | 53.0 | 241.0 | 61 | 4.55 | 49.9 | 255.6 | 65 | 5.12 | 47.3 | 226.3 | 67 | 4.78 | 48.6 | 328.9 | 88 | 6.77 | 129.6 | 839.5 | 288 | 6.48 | 222.8 | 1378.4 | 566 | 6.19 | 278.3 | 1547.0 | 630 | 5.56 | ||||||||||||
2024 | Sole/Wasser | Novelan - SICV 6.2H3 | 6.3 | 2018 | 185 | 6 | 2108.7 | 10354.5 | 3806 | 4.91 | 324.0 | 1561.0 | 644 | 4.82 | 401.5 | 1783.7 | 625 | 4.44 | 346.0 | 1521.5 | 607 | 4.40 | 136.0 | 535.0 | 166 | 3.93 | 97.0 | 422.0 | 122 | 4.35 | 61.0 | 261.3 | 66 | 4.28 | 57.1 | 254.2 | 64 | 4.45 | 39.7 | 172.5 | 44 | 4.35 | 41.0 | 206.4 | 53 | 5.03 | 117.8 | 762.0 | 265 | 6.47 | 223.1 | 1389.2 | 555 | 6.23 | 264.5 | 1485.7 | 595 | 5.62 | ||||||||||||
2024 | Sole/Wasser | Novelan - SICV 6.2H3 | 6.3 | 2017 | 185 | 6 | 1500.0 | 7186.1 | 2719 | 4.79 | 241.0 | 976.0 | 398 | 4.05 | 225.0 | 1018.0 | 406 | 4.52 | 113.4 | 436.2 | 144 | 3.85 | 63.3 | 237.1 | 62 | 3.75 | 57.1 | 252.3 | 64 | 4.42 | 52.6 | 226.6 | 57 | 4.31 | 67.0 | 362.0 | 114 | 5.40 | 101.0 | 541.4 | 188 | 5.36 | 234.6 | 1361.5 | 567 | 5.80 | 345.0 | 1775.0 | 719 | 5.14 |
NR | 2024 |
Username | MiKe0507 |
Einbaujahr der WP | 2016-10-06 |
PLZ des Wohnortes | 82288 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Novelan - SICV 6.2H3 |
modulierend | Ja |
Leistung (0/35) | 6.3 kW |
berechneter Primärenergiebedarf | 15.8 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 48 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Grabenkollektor |
Tiefe | 1.8 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt DB |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 32.0 °C |
Spreizung Heizkr. | 3.0 |
Heizflaeche | 185 m² |
Lüftung | zenKWLWR |
Personen | 6 |
Grabenkollektor Helfer | Ja |
Grabenkollektor Erfahrung | Ja |
Bemerkungen | Inbetriebnahme der Wärmepumpe am 06.10.2016. Es wurde mit Estrichaufheizen begonnen. Warmwasserbereitung ab 17.12.2016. Stromzähler für Wärmepumpe wurde erst ab 13.03.2017 eingebaut. |