Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2135 | Sole/Wasser | NIBE F1255-6 | 3.2 | 2022 | 190 | 3 | 751.9 | 3921.0 | 1458 | 5.21 | 383.4 | 2016.0 | 741 | 5.26 | 368.5 | 1905.0 | 717 | 5.17 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
2135 | Sole/Wasser | NIBE F1255-6 | 3.2 | 2021 | 190 | 3 | 2949.0 | 13369.0 | 4823 | 4.53 | 465.3 | 2352.0 | 762 | 5.05 | 384.3 | 1855.0 | 593 | 4.83 | 390.0 | 1951.0 | 744 | 5.00 | 256.1 | 1300.0 | 553 | 5.08 | 156.5 | 708.0 | 279 | 4.52 | 66.5 | 191.0 | 51 | 2.87 | 66.0 | 192.0 | 53 | 2.91 | 55.5 | 159.0 | 42 | 2.86 | 238.6 | 495.0 | 178 | 2.07 | 238.6 | 495.0 | 178 | 2.07 | 315.8 | 1835.5 | 695 | 5.81 | 315.8 | 1835.5 | 695 | 5.81 | ||||||||||||
2135 | Sole/Wasser | NIBE F1255-6 | 3.2 | 2020 | 190 | 3 | 2268.3 | 11817.0 | 4515 | 5.21 | 349.1 | 1990.0 | 740 | 5.70 | 320.7 | 1824.0 | 674 | 5.69 | 339.5 | 1869.0 | 727 | 5.51 | 169.2 | 814.0 | 304 | 4.81 | 137.5 | 667.0 | 255 | 4.85 | 67.3 | 204.0 | 51 | 3.03 | 77.6 | 236.0 | 61 | 3.04 | 58.3 | 166.0 | 45 | 2.85 | 52.7 | 139.0 | 36 | 2.64 | 128.1 | 710.0 | 293 | 5.54 | 239.0 | 1414.0 | 608 | 5.92 | 329.3 | 1784.0 | 721 | 5.42 | ||||||||||||
2135 | Sole/Wasser | NIBE F1255-6 | 3.2 | 2019 | 190 | 3 | 2348.4 | 11847.0 | 4649 | 5.04 | 414.0 | 2102.0 | 726 | 5.08 | 304.7 | 1298.0 | 689 | 4.26 | 274.7 | 1319.0 | 635 | 4.80 | 198.2 | 907.0 | 371 | 4.58 | 176.6 | 839.0 | 329 | 4.75 | 62.4 | 179.0 | 45 | 2.87 | 67.8 | 212.0 | 55 | 3.13 | 60.1 | 184.0 | 48 | 3.06 | 65.8 | 231.0 | 60 | 3.51 | 163.3 | 1035.0 | 325 | 6.34 | 241.8 | 1590.0 | 630 | 6.58 | 319.0 | 1951.0 | 736 | 6.12 | ||||||||||||
2135 | Sole/Wasser | NIBE F1255-6 | 3.2 | 2018 | 190 | 3 | 2518.2 | 11637.0 | 4426 | 4.62 | 443.0 | 1945.0 | 687 | 4.39 | 416.0 | 1871.8 | 658 | 4.50 | 439.2 | 1933.2 | 726 | 4.40 | 177.0 | 593.0 | 320 | 3.35 | 88.4 | 274.0 | 86 | 3.10 | 69.8 | 187.0 | 48 | 2.68 | 67.3 | 177.0 | 48 | 2.63 | 48.5 | 129.0 | 36 | 2.66 | 72.1 | 322.0 | 96 | 4.47 | 133.0 | 851.0 | 365 | 6.40 | 252.9 | 1609.0 | 665 | 6.36 | 311.0 | 1745.0 | 691 | 5.61 |
NR | 2135 |
Username | matten666 |
Einbaujahr der WP | 2017-10-22 |
PLZ des Wohnortes | 21635 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | NIBE F1255-6 |
modulierend | Ja |
Leistung (0/35) | 3.2 kW |
berechneter Primärenergiebedarf | 34.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 45 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Grabenkollektor |
Tiefe | 1.5 m |
Fläche | 117 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt |
elektr. Verbrauch HP gem./DB | 2 Watt |
elektr. Verbrauch WQ P gem./DB | 10 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 35.0 °C |
Spreizung Heizkr. | 4.0 |
Heizflaeche | 190 m² |
Lüftung | zenKWLWR |
Personen | 3 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | Ja |
Bemerkungen |