Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2151 | Sole/Wasser | Junkers SupraEco STE 80-1 | 7.6 | 2023 | 166 | 4 | 1460.2 | 1460.2 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2151 | Sole/Wasser | Junkers SupraEco STE 80-1 | 7.6 | 2022 | 166 | 4 | 1157.0 | 8854.8 | 4.45 | 345.0 | 1529.1 | 4.43 | 397.0 | 1757.2 | 4.43 | 182.0 | 793.4 | 4.36 | 186.0 | 795.7 | 4.28 | 47.0 | 273.7 | 5.82 | 223.9 | 214.3 | 144.5 | 284.3 | 363.4 | 946.5 | 1528.8 | |||||||||||||||||||||||||||||||||||||||
2151 | Sole/Wasser | Junkers SupraEco STE 80-1 | 7.6 | 2021 | 166 | 4 | 2628.0 | 11109.9 | 4.44 | 405.0 | 1772.6 | 4.38 | 424.0 | 1836.2 | 4.33 | 282.0 | 1215.7 | 4.31 | 208.0 | 902.2 | 4.34 | 124.0 | 120.0 | 924.0 | 7.70 | 72.0 | 225.3 | 3.13 | 63.0 | 189.5 | 3.01 | 90.0 | 311.7 | 3.46 | 157.0 | 673.4 | 4.29 | 311.0 | 1397.1 | 4.49 | 372.0 | 1662.2 | 4.47 | |||||||||||||||||||||||||||
2151 | Sole/Wasser | Junkers SupraEco STE 80-1 | 7.6 | 2020 | 166 | 4 | 2248.0 | 9401.7 | 4.18 | 373.0 | 1688.7 | 4.53 | 267.0 | 1175.4 | 4.40 | 236.0 | 1018.0 | 4.31 | 184.0 | 748.4 | 4.07 | 131.0 | 501.9 | 3.83 | 76.0 | 254.9 | 3.35 | 74.0 | 226.6 | 3.06 | 72.0 | 218.9 | 3.04 | 77.0 | 264.2 | 3.43 | 159.0 | 643.4 | 4.05 | 251.0 | 1112.2 | 4.43 | 348.0 | 1549.1 | 4.45 | |||||||||||||||||||||||||
2151 | Sole/Wasser | Junkers SupraEco STE 80-1 | 7.6 | 2019 | 166 | 4 | 2407.0 | 9980.0 | 4.15 | 396.0 | 1758.0 | 4.44 | 317.0 | 1390.8 | 4.39 | 274.0 | 1176.9 | 4.30 | 197.0 | 819.2 | 4.16 | 147.0 | 580.7 | 3.95 | 47.0 | 133.8 | 2.85 | 61.0 | 179.0 | 2.93 | 59.0 | 171.0 | 2.90 | 76.0 | 246.3 | 3.24 | 148.0 | 599.4 | 4.05 | 362.0 | 1622.5 | 4.48 | 323.0 | 1302.4 | 4.03 | |||||||||||||||||||||||||
2151 | Sole/Wasser | Junkers SupraEco STE 80-1 | 7.6 | 2018 | 166 | 3 | 2499.0 | 10424.8 | 4.17 | 535.0 | 2373.6 | 4.44 | 447.0 | 1946.5 | 4.35 | 358.0 | 1542.4 | 4.31 | 130.0 | 498.3 | 3.83 | 78.0 | 260.3 | 3.34 | 52.0 | 146.7 | 2.82 | 52.0 | 149.6 | 2.88 | 58.0 | 168.2 | 2.90 | 73.0 | 240.3 | 3.29 | 134.0 | 528.5 | 3.94 | 252.0 | 1112.4 | 4.41 | 330.0 | 1458.0 | 4.42 |
NR | 2151 |
Username | mguettle |
Einbaujahr der WP | 2017-08-17 |
PLZ des Wohnortes | 67459 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Junkers SupraEco STE 80-1 |
modulierend | Nein |
Leistung (0/35) | 7.6 kW |
berechneter Primärenergiebedarf | 51.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 60 °C |
WW Legionellenschaltung | wöchentlich |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | 2 Erdbohrungen |
Tiefe | 70.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt DB |
elektr. Verbrauch HP gem./DB | 45 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 20 °C |
Mittlere Wärmequellentemperatur | 2.0 °C |
Heizung max. Vorlauf Temp. | 35.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 166 m² |
Lüftung | Fenster |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen |