Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2175 | Luft/Wasser | iDM TERRA ML 8-13 | 8.2 | 2020 | 280 | 3 | 2434.6 | 7293.4 | 3.00 | 646.9 | 2157.2 | 3.33 | 531.6 | 1795.9 | 3.38 | 377.9 | 1194.6 | 3.16 | 284.4 | 812.3 | 2.86 | 146.2 | 328.2 | 2.24 | 110.1 | 247.2 | 2.25 | 113.7 | 255.4 | 2.25 | 113.7 | 255.4 | 2.25 | 110.1 | 247.2 | 2.25 | ||||||||||||||||||||||||||||||||||
2175 | Luft/Wasser | iDM TERRA ML 8-13 | 8.2 | 2019 | 280 | 3 | 3532.2 | 8684.2 | 2.94 | 724.3 | 2369.5 | 3.27 | 526.9 | 1742.4 | 3.31 | 337.1 | 1108.3 | 3.29 | 157.9 | 356.1 | 2.26 | 143.8 | 285.5 | 1.99 | 112.2 | 244.3 | 2.18 | 116.6 | 272.5 | 2.34 | 123.7 | 288.3 | 2.33 | 126.1 | 287.7 | 2.28 | 238.1 | 668.6 | 2.81 | 342.5 | 1061.0 | 3.10 | 583.0 | |||||||||||||||||||||||||||
2175 | Luft/Wasser | iDM TERRA ML 8-13 | 8.2 | 2018 | 280 | 2 | 3298.6 | 10189.9 | 3.09 | 466.1 | 1655.2 | 3.55 | 577.0 | 1884.0 | 3.27 | 485.4 | 1554.6 | 3.20 | 136.4 | 308.5 | 2.26 | 109.9 | 253.8 | 2.31 | 98.7 | 219.9 | 2.23 | 93.8 | 208.9 | 2.23 | 106.1 | 233.9 | 2.20 | 109.5 | 227.6 | 2.08 | 137.1 | 276.0 | 2.01 | 390.0 | 1306.1 | 3.35 | 588.6 | 2061.4 | 3.50 | |||||||||||||||||||||||||
2175 | Luft/Wasser | iDM TERRA ML 8-13 | 8.2 | 2017 | 280 | 2 | 3358.9 | 10419.8 | 3.10 | 808.6 | 2457.5 | 3.04 | 468.2 | 1747.4 | 3.73 | 322.7 | 1083.1 | 3.36 | 149.7 | 263.5 | 1.76 | 117.2 | 248.2 | 2.12 | 94.0 | 213.3 | 2.27 | 92.9 | 210.2 | 2.26 | 84.6 | 180.9 | 2.14 | 106.1 | 205.3 | 1.93 | 176.7 | 423.5 | 2.40 | 429.6 | 1545.3 | 3.60 | 508.6 | 1841.6 | 3.62 | |||||||||||||||||||||||||
2175 | Luft/Wasser | iDM TERRA ML 8-13 | 8.2 | 2016 | 280 | 2 | 1572.6 | 5346.2 | 3.40 | 118.2 | 261.8 | 2.21 | 322.3 | 1102.7 | 3.42 | 510.6 | 1822.5 | 3.57 | 621.5 | 2159.2 | 3.47 |
NR | 2175 |
Username | Galdan |
Einbaujahr der WP | 2016-06-01 |
PLZ des Wohnortes | 84036 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | iDM TERRA ML 8-13 |
modulierend | |
Leistung (0/35) | 8.2 kW |
berechneter Primärenergiebedarf | 35.4 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 48 °C |
WW Legionellenschaltung | Ja |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 30.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 280 m² |
Lüftung | dezKWLWR |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | DHH Neubau - Bezug August 2016 |