Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2290 | Sole/Wasser | Dimplex SI 6TU | 6.1 | 2023 | 154 | 1 | 360.0 | 2149.0 | 281 | 5.97 | 145.0 | 881.0 | 114 | 6.08 | 117.0 | 700.0 | 93 | 5.98 | 98.0 | 568.0 | 74 | 5.80 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |||||||||||||||||||||||||||||||||
2290 | Sole/Wasser | Dimplex SI 6TU | 6.1 | 2022 | 154 | 1 | 246.0 | 1499.0 | 184 | 6.09 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 70.0 | 431.0 | 50 | 6.16 | 176.0 | 1068.0 | 134 | 6.07 | |||||||||||||||||||||||||||||||
2290 | Sole/Wasser | Dimplex SI 6TU | 6.1 | 2021 | 154 | 1 | 521.1 | 3104.0 | 367 | 5.96 | 154.0 | 906.0 | 121 | 5.88 | 130.0 | 780.0 | 102 | 6.00 | 100.0 | 646.0 | 61 | 6.46 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 20.1 | 140.0 | 10 | 6.97 | 117.0 | 632.0 | 73 | 5.40 | ||||||||||||||||||||||
2290 | Sole/Wasser | Dimplex SI 6TU | 6.1 | 2020 | 154 | 1 | 448.3 | 2856.1 | 359 | 6.37 | 116.8 | 690.1 | 90 | 5.91 | 111.3 | 661.0 | 88 | 5.94 | 45.0 | 277.0 | 36 | 6.16 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 9.9 | 67.0 | 6 | 6.77 | 48.3 | 347.0 | 39 | 7.18 | 117.0 | 814.0 | 100 | 6.96 | ||||||||||||||||||
2290 | Sole/Wasser | Dimplex SI 6TU | 6.1 | 2019 | 154 | 1 | 482.7 | 2952.0 | 377 | 6.12 | 115.0 | 687.0 | 88 | 5.97 | 75.1 | 418.0 | 59 | 5.57 | 74.6 | 450.0 | 60 | 6.03 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 102.0 | 667.0 | 78 | 6.54 | 116.0 | 730.0 | 92 | 6.29 | |||||||||||||||||||
2290 | Sole/Wasser | Dimplex SI 6TU | 6.1 | 2018 | 154 | 1 | 175.6 | 1084.0 | 126 | 6.17 | 96.0 | 591.0 | 65 | 6.16 | 79.6 | 493.0 | 61 | 6.19 |
NR | 2290 |
Username | nevtag |
Einbaujahr der WP | 2018-03-20 |
PLZ des Wohnortes | 28844 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Tri |
Hersteller Typ | Dimplex SI 6TU |
modulierend | Nein |
Leistung (0/35) | 6.1 kW |
berechneter Primärenergiebedarf | 15.9 kWh/m²/anno |
WW über WP | Nein |
WW Temperatur | 45 °C |
WW Legionellenschaltung | wöchentlich |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | sonstige |
Tiefe | 4.0 m |
Fläche | 130 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 1300 Watt DB |
elektr. Verbrauch HP gem./DB | 25 Watt |
elektr. Verbrauch WQ P gem./DB | 33 Watt |
Stromzähler | extern > erfasst: |
WMZ | intern |
Mittlere Raumtemp. | 23.0 °C |
Mittlere Wärmequellentemperatur | 8.5 °C |
Heizung max. Vorlauf Temp. | 33.0 °C |
Spreizung Heizkr. | 4.0 |
Heizflaeche | 154 m² |
Lüftung | zenKWLWR |
Personen | 1 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | SI 6TU Wärmequelle: 3 Kreise a 300m je Kreis mit 2 Wärmekörben, Tiefe 2-4m (Grundwasser) Der WP-Manager ist nur für die Sicherheitsfunktionen der WP. Gesteuert wird die WP(externe Sperre) und die Pumpen über eine RSM-610. Kamin mit Abgaswärmetauscher aus Edelstahl Warmwasser über DHW300plus, in KWL eingebunden und über RSM-610, als Ersatz für den WP-Manager PV 16kWp, 36kW Speicher |