Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2295 | Sole/Wasser | Nibe F1255-12 | 12.0 | 2023 | 320 | 4 | 4587.0 | 15201.0 | 4033 | 3.31 | 940.0 | 2811.0 | 702 | 2.99 | 946.0 | 2725.0 | 755 | 2.88 | 952.0 | 2936.0 | 678 | 3.08 | 846.0 | 2607.0 | 738 | 3.08 | 446.0 | 2647.0 | 650 | 5.93 | 347.0 | 911.0 | 336 | 2.63 | 110.0 | 564.0 | 174 | 5.13 | ||||||||||||||||||||||||||||||||
2295 | Sole/Wasser | Nibe F1255-12 | 12.0 | 2022 | 320 | 4 | 6885.0 | 24855.0 | 6068 | 3.61 | 827.0 | 3981.0 | 743 | 4.81 | 1000.0 | 3522.0 | 679 | 3.52 | 1021.0 | 3385.0 | 742 | 3.32 | 842.0 | 2688.0 | 663 | 3.19 | 250.0 | 1274.0 | 453 | 5.10 | 251.0 | 539.0 | 180 | 2.15 | 177.0 | 323.0 | 171 | 1.82 | 176.0 | 181.0 | 183 | 1.03 | 410.0 | 1587.0 | 356 | 3.87 | 462.0 | 1613.0 | 484 | 3.49 | 730.0 | 2270.0 | 679 | 3.11 | 739.0 | 3492.0 | 735 | 4.73 | ||||||||||||
2295 | Sole/Wasser | Nibe F1255-12 | 12.0 | 2021 | 320 | 4 | 7247.0 | 23045.0 | 6083 | 3.18 | 983.0 | 3521.0 | 751 | 3.58 | 890.0 | 3025.0 | 736 | 3.40 | 998.0 | 2782.0 | 741 | 2.79 | 452.0 | 2516.0 | 702 | 5.57 | 754.0 | 2000.0 | 724 | 2.65 | 150.0 | 105.0 | 85 | 0.70 | 112.0 | 32.0 | 61 | 0.29 | 182.0 | 144.0 | 120 | 0.79 | 300.0 | 663.0 | 222 | 2.21 | 301.0 | 1665.0 | 523 | 5.53 | 1312.0 | 2639.0 | 651 | 2.01 | 813.0 | 3953.0 | 767 | 4.86 | ||||||||||||
2295 | Sole/Wasser | Nibe F1255-12 | 12.0 | 2020 | 320 | 3 | 6478.0 | 33969.0 | 6121 | 5.24 | 1053.0 | 7686.0 | 747 | 7.30 | 754.0 | 5825.0 | 688 | 7.73 | 757.0 | 5544.0 | 706 | 7.32 | 349.0 | 3213.0 | 604 | 9.21 | 681.0 | 2114.0 | 385 | 3.10 | 72.0 | 242.0 | 83 | 3.36 | 100.0 | 225.0 | 129 | 2.25 | 139.0 | 137.0 | 81 | 0.99 | 325.0 | 1109.0 | 501 | 3.41 | 647.0 | 1647.0 | 733 | 2.55 | 812.0 | 2693.0 | 720 | 3.32 | 789.0 | 3534.0 | 744 | 4.48 | ||||||||||||
2295 | Sole/Wasser | Nibe F1255-12 | 12.0 | 2019 | 320 | 5 | 6183.0 | 34092.0 | 5479 | 5.51 | 611.0 | 2405.0 | 599 | 3.94 | 454.0 | 1915.0 | 589 | 4.22 | 434.0 | 1809.0 | 646 | 4.17 | 412.0 | 2148.0 | 566 | 5.21 | 418.0 | 1265.0 | 523 | 3.03 | 73.0 | 225.0 | 74 | 3.08 | 82.0 | 422.0 | 42 | 5.15 | 52.0 | 46.0 | 42 | 0.88 | 122.0 | 317.0 | 300 | 2.60 | 657.0 | 5521.0 | 663 | 8.40 | 1159.0 | 8594.0 | 689 | 7.42 | 1709.0 | 9425.0 | 746 | 5.51 |
NR | 2295 |
Username | dgtom |
Einbaujahr der WP | 2017-09-20 |
PLZ des Wohnortes | 31700 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Nibe F1255-12 |
modulierend | Ja |
Leistung (0/35) | 12.0 kW |
berechneter Primärenergiebedarf | 12.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 45 °C |
WW Legionellenschaltung | Ja |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Grabenkollektor |
Tiefe | 1.8 m |
Fläche | 0 m² |
Heizungsart | FBH und Radiatoren |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt DB |
elektr. Verbrauch HP gem./DB | 2 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 8.0 °C |
Heizung max. Vorlauf Temp. | 49.0 °C |
Spreizung Heizkr. | 3.0 |
Heizflaeche | 320 m² |
Lüftung | Fenster |
Personen | 5 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | nein |
Bemerkungen | Altbau, teilweise saniert mit FBH, Zwischenwanddämung, neue Fenster und Dachdämmung gemäß gemäß KfW 115. |