Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2296 | Sole/Wasser | Nibe F1155-6 PC | 4.5 | 2023 | 261 | 5 | 900.0 | 2350.0 | 1750 | 2.61 | 180.0 | 470.0 | 350 | 2.61 | 180.0 | 470.0 | 350 | 2.61 | 180.0 | 470.0 | 350 | 2.61 | 180.0 | 470.0 | 350 | 2.61 | 180.0 | 470.0 | 350 | 2.61 | ||||||||||||||||||||||||||||||||||||||||
2296 | Sole/Wasser | Nibe F1155-6 PC | 4.5 | 2022 | 261 | 5 | 2160.0 | 5640.0 | 4200 | 2.61 | 180.0 | 470.0 | 350 | 2.61 | 180.0 | 470.0 | 350 | 2.61 | 180.0 | 470.0 | 350 | 2.61 | 180.0 | 470.0 | 350 | 2.61 | 180.0 | 470.0 | 350 | 2.61 | 180.0 | 470.0 | 350 | 2.61 | 180.0 | 470.0 | 350 | 2.61 | 180.0 | 470.0 | 350 | 2.61 | 180.0 | 470.0 | 350 | 2.61 | 180.0 | 470.0 | 350 | 2.61 | 180.0 | 470.0 | 350 | 2.61 | 180.0 | 470.0 | 350 | 2.61 | ||||||||||||
2296 | Sole/Wasser | Nibe F1155-6 PC | 4.5 | 2021 | 261 | 5 | 2349.0 | 7802.0 | 3869 | 3.47 | 371.0 | 1741.0 | 709 | 4.69 | 321.0 | 1325.0 | 509 | 4.13 | 251.0 | 974.0 | 539 | 3.88 | 168.0 | 512.0 | 219 | 3.05 | 147.0 | 402.0 | 133 | 2.73 | 115.0 | 259.0 | 72 | 2.25 | 98.0 | 243.0 | 72 | 2.48 | 100.0 | 82 | 105.0 | 107.0 | 135 | 1.02 | 127.0 | 130.0 | 164 | 1.02 | 241.0 | 929.0 | 544 | 3.85 | 305.0 | 1180.0 | 691 | 3.87 | ||||||||||||||
2296 | Sole/Wasser | Nibe F1155-6 PC | 4.5 | 2020 | 261 | 5 | 1962.0 | 7351.0 | 3529 | 3.75 | 279.0 | 1143.0 | 689 | 4.10 | 258.0 | 958.0 | 614 | 3.71 | 227.0 | 624.0 | 368 | 2.75 | 131.0 | 366.0 | 127 | 2.79 | 105.0 | 260.0 | 79 | 2.48 | 97.0 | 219.0 | 64 | 2.26 | 93.0 | 227.0 | 77 | 2.44 | 81.0 | 192.0 | 66 | 2.37 | 81.0 | 201.0 | 62 | 2.48 | 108.0 | 462.0 | 62 | 4.28 | 198.0 | 1079.0 | 588 | 5.45 | 304.0 | 1620.0 | 733 | 5.33 | ||||||||||||
2296 | Sole/Wasser | Nibe F1155-6 PC | 4.5 | 2019 | 261 | 5 | 1671.0 | 8280.0 | 4711 | 4.96 | 346.0 | 1375.0 | 642 | 3.97 | 103.0 | 749.0 | 680 | 7.27 | 170.0 | 1412.0 | 900 | 8.31 | 74.0 | 700.0 | 471 | 9.46 | 93.0 | 566.0 | 350 | 6.09 | 105.0 | 247.0 | 145 | 2.35 | 89.0 | 214.0 | 133 | 2.40 | 78.0 | 183.0 | 54 | 2.35 | 79.0 | 198.0 | 59 | 2.51 | 86.0 | 233.0 | 77 | 2.71 | 174.0 | 931.0 | 488 | 5.35 | 274.0 | 1472.0 | 712 | 5.37 | ||||||||||||
2296 | Sole/Wasser | Nibe F1155-6 PC | 4.5 | 2018 | 261 | 5 | 602.0 | 2626.0 | 1084 | 4.36 | 340.0 | 1654.0 | 340 | 4.86 | 262.0 | 972.0 | 744 | 3.71 |
NR | 2296 |
Username | fgrewe |
Einbaujahr der WP | 2018-11-16 |
PLZ des Wohnortes | 21149 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Nibe F1155-6 PC |
modulierend | Ja |
Leistung (0/35) | 4.5 kW |
berechneter Primärenergiebedarf | 26.4 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 55 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Grabenkollektor |
Tiefe | 2.0 m |
Fläche | 180 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 20.0 °C |
Mittlere Wärmequellentemperatur | 6.0 °C |
Heizung max. Vorlauf Temp. | 29.0 °C |
Spreizung Heizkr. | 5.0 |
Heizflaeche | 261 m² |
Lüftung | dezKWLWR |
Personen | 5 |
Grabenkollektor Helfer | Ja |
Grabenkollektor Erfahrung | Eher schnell-schnell verlegt. 2x300m |
Bemerkungen | Erst Mitte 2019 habe ich einen separaten Stromzähler für die Heizung eingebaut, vorher waren die Stromverbräuche nur errechnet. Wir haben keine Solarunterstützung. Im Sommer kühlen wir (PC = Passive Cooling) und wir haben das ganze Jahr zwecks Kühlung und Wärmeverteilung die Heizkreis-Pumpe laufen. Im Stromverbrauch sind diese Verbräuche mit erfasst. Die Kühlleistung (WMZ) geben wir nicht mit an. |