Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2310 | Sole/Wasser | KNV-1255-6 PC | 6.0 | 2024 | 167 | 2 | 598.5 | 3134.9 | 1298 | 5.24 | 342.5 | 1825.9 | 696 | 5.33 | 256.0 | 1309.0 | 602 | 5.11 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
2310 | Sole/Wasser | KNV-1255-6 PC | 6.0 | 2023 | 167 | 2 | 1928.2 | 9679.8 | 4118 | 5.02 | 302.0 | 1668.0 | 714 | 5.52 | 277.4 | 1433.4 | 591 | 5.17 | 233.5 | 1184.6 | 535 | 5.07 | 202.8 | 1036.7 | 502 | 5.11 | 112.2 | 485.0 | 222 | 4.32 | 59.9 | 131.0 | 34 | 2.19 | 76.0 | 183.0 | 49 | 2.41 | 72.5 | 182.1 | 52 | 2.51 | 43.5 | 110.7 | 30 | 2.54 | 86.3 | 414.9 | 166 | 4.81 | 184.3 | 1186.2 | 524 | 6.44 | 277.8 | 1664.2 | 699 | 5.99 | ||||||||||||
2310 | Sole/Wasser | KNV-1255-6 PC | 6.0 | 2022 | 167 | 2 | 2072.0 | 10389.1 | 4393 | 5.01 | 339.4 | 1804.5 | 716 | 5.32 | 265.9 | 1367.3 | 592 | 5.14 | 281.7 | 1358.7 | 558 | 4.82 | 207.4 | 1046.4 | 498 | 5.05 | 94.8 | 318.8 | 126 | 3.36 | 76.0 | 171.0 | 53 | 2.25 | 60.0 | 123.0 | 35 | 2.05 | 59.1 | 130.3 | 38 | 2.20 | 68.9 | 270.8 | 114 | 3.93 | 115.8 | 706.8 | 315 | 6.10 | 196.4 | 1281.5 | 618 | 6.52 | 306.6 | 1810.0 | 730 | 5.90 | ||||||||||||
2310 | Sole/Wasser | KNV-1255-6 PC | 6.0 | 2021 | 167 | 2 | 2267.0 | 11378.4 | 4701 | 5.02 | 363.4 | 1943.3 | 736 | 5.35 | 311.7 | 1569.3 | 613 | 5.03 | 294.9 | 1456.0 | 607 | 4.94 | 211.0 | 1031.5 | 479 | 4.89 | 142.9 | 655.5 | 329 | 4.59 | 70.0 | 171.3 | 60 | 2.45 | 74.3 | 170.3 | 47 | 2.29 | 62.2 | 159.6 | 46 | 2.57 | 68.5 | 240.0 | 86 | 3.50 | 139.1 | 834.0 | 359 | 6.00 | 218.1 | 1369.2 | 614 | 6.28 | 310.9 | 1778.4 | 725 | 5.72 | ||||||||||||
2310 | Sole/Wasser | KNV-1255-6 PC | 6.0 | 2020 | 167 | 2 | 2046.8 | 10604.5 | 4574 | 5.18 | 366.0 | 1987.4 | 745 | 5.43 | 248.0 | 1321.5 | 614 | 5.33 | 233.9 | 1222.8 | 590 | 5.23 | 155.0 | 731.0 | 324 | 4.72 | 109.7 | 482.1 | 233 | 4.39 | 73.0 | 231.0 | 93 | 3.16 | 54.7 | 111.1 | 28 | 2.03 | 65.0 | 159.0 | 47 | 2.45 | 67.0 | 242.0 | 88 | 3.61 | 142.0 | 894.0 | 424 | 6.30 | 214.8 | 1356.5 | 634 | 6.32 | 317.7 | 1866.1 | 754 | 5.87 | ||||||||||||
2310 | Sole/Wasser | KNV-1255-6 PC | 6.0 | 2019 | 167 | 2 | 2100.1 | 10608.6 | 4276 | 5.05 | 418.0 | 2109.0 | 696 | 5.05 | 325.8 | 1541.0 | 527 | 4.73 | 225.0 | 1153.0 | 476 | 5.12 | 148.2 | 732.5 | 327 | 4.94 | 142.2 | 747.8 | 403 | 5.26 | 62.3 | 132.7 | 50 | 2.13 | 65.4 | 159.5 | 55 | 2.44 | 60.2 | 143.0 | 48 | 2.38 | 57.7 | 240.5 | 94 | 4.17 | 148.9 | 856.1 | 331 | 5.75 | 171.4 | 1126.9 | 565 | 6.57 | 275.0 | 1666.6 | 704 | 6.06 | ||||||||||||
2310 | Sole/Wasser | KNV-1255-6 PC | 6.0 | 2018 | 167 | 635.0 | 3617.0 | 1220 | 5.70 | 102.0 | 482.0 | 143 | 4.73 | 212.0 | 1290.0 | 406 | 6.08 | 321.0 | 1845.0 | 671 | 5.75 |
NR | 2310 |
Username | Ranzoni |
Einbaujahr der WP | 2017-12-19 |
PLZ des Wohnortes | A-1100 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | KNV-1255-6 PC |
modulierend | Ja |
Leistung (0/35) | 6.0 kW |
berechneter Primärenergiebedarf | 47.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 48 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Grabenkollektor |
Tiefe | 2.0 m |
Fläche | 112 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | extern > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | intern |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 35.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 167 m² |
Lüftung | Fenster |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen |