Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2314 | Sole/Wasser | Heliotherm SMS 1-6kW | 6.9 | 2022 | 150 | 4 | 507.0 | 2470.0 | 979 | 4.87 | 182.0 | 890.0 | 304 | 4.89 | 180.0 | 870.0 | 390 | 4.83 | 145.0 | 710.0 | 285 | 4.90 | ||||||||||||||||||||||||||||||||||||||||||||||||
2314 | Sole/Wasser | Heliotherm SMS 1-6kW | 6.9 | 2021 | 150 | 3 | 1183.9 | 5226.0 | 1461 | 4.41 | 208.0 | 1099.0 | 350 | 5.28 | 210.0 | 1050.0 | 360 | 5.00 | 185.0 | 890.0 | 270 | 4.81 | 200.0 | 800.0 | 225 | 4.00 | 250.0 | 800.0 | 133 | 3.20 | 4.9 | 20.0 | 2 | 4.08 | 5.0 | 20.0 | 4 | 4.00 | 0 | 0 | 0 | 41.0 | 97.0 | 15 | 2.37 | 80.0 | 450.0 | 102 | 5.63 | |||||||||||||||||||||
2314 | Sole/Wasser | Heliotherm SMS 1-6kW | 6.9 | 2020 | 150 | 3 | 1091.0 | 5168.0 | 1564 | 4.74 | 213.0 | 1090.0 | 377 | 5.12 | 162.0 | 785.0 | 269 | 4.85 | 186.0 | 880.0 | 275 | 4.73 | 37.0 | 157.0 | 25 | 4.24 | 38.0 | 136.0 | 38 | 3.58 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 89.0 | 207.0 | 50 | 2.33 | 75.0 | 412.0 | 90 | 5.49 | 97.0 | 521.0 | 120 | 5.37 | 194.0 | 980.0 | 320 | 5.05 | |||||||||||||||
2314 | Sole/Wasser | Heliotherm SMS 1-6kW | 6.9 | 2019 | 150 | 3 | 1300.0 | 5728.0 | 1935 | 4.41 | 331.0 | 1409.0 | 570 | 4.26 | 244.0 | 1119.0 | 388 | 4.59 | 167.0 | 611.0 | 250 | 3.66 | 71.0 | 292.0 | 106 | 4.11 | 143.0 | 446.0 | 113 | 3.12 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 13.0 | 23.0 | 12 | 1.77 | 61.0 | 313.0 | 86 | 5.13 | 106.0 | 608.0 | 110 | 5.74 | 164.0 | 907.0 | 300 | 5.53 |
NR | 2314 |
Username | Helyx |
Einbaujahr der WP | 2018-09-01 |
PLZ des Wohnortes | A-6835 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Heliotherm SMS 1-6kW |
modulierend | Ja |
Leistung (0/35) | 6.9 kW |
berechneter Primärenergiebedarf | 25.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 45 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Grabenkollektor |
Tiefe | 2.5 m |
Fläche | 50 m² |
Heizungsart | FBH und Wandheizung |
elektr. Verbrauch WP ohne NA gem./DB | 18 Watt gem. |
elektr. Verbrauch HP gem./DB | 20 Watt |
elektr. Verbrauch WQ P gem./DB | 15 Watt |
Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | extern_geeicht |
Mittlere Raumtemp. | 23.0 °C |
Mittlere Wärmequellentemperatur | 6.0 °C |
Heizung max. Vorlauf Temp. | 30.0 °C |
Spreizung Heizkr. | 4.0 |
Heizflaeche | 150 m² |
Lüftung | zenKWLWR |
Personen | 3 |
Grabenkollektor Helfer | Ja |
Grabenkollektor Erfahrung | Ja |
Bemerkungen |