Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2321 | Luft/Wasser | Viessmann Vitocal 200-S | 9.5 | 2022 | 170 | 4 | 1290.0 | 543.0 | 387.0 | 360.0 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2321 | Luft/Wasser | Viessmann Vitocal 200-S | 9.5 | 2021 | 170 | 4 | 3278.0 | 570.0 | 410.0 | 360.0 | 270.0 | 200.0 | 100.0 | 88.0 | 90.0 | 110.0 | 220.0 | 410.0 | 450.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
2321 | Luft/Wasser | Viessmann Vitocal 200-S | 9.5 | 2020 | 170 | 4 | 2720.0 | 500.0 | 354.0 | 336.0 | 130.0 | 120.0 | 100.0 | 90.0 | 80.0 | 80.0 | 190.0 | 310.0 | 430.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
2321 | Luft/Wasser | Viessmann Vitocal 200-S | 9.5 | 2019 | 170 | 3 | 3120.0 | 600.0 | 414.0 | 326.0 | 220.0 | 192.0 | 98.0 | 85.0 | 92.0 | 106.0 | 177.0 | 400.0 | 410.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
2321 | Luft/Wasser | Viessmann Vitocal 200-S | 9.5 | 2018 | 170 | 3 | 1597.0 | 140.0 | 110.0 | 100.0 | 65.0 | 92.0 | 200.0 | 420.0 | 470.0 |
NR | 2321 |
Username | huette82 |
Einbaujahr der WP | 2018-05-01 |
PLZ des Wohnortes | 66482 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Viessmann Vitocal 200-S |
modulierend | |
Leistung (0/35) | 9.5 kW |
berechneter Primärenergiebedarf | 51.7 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 42 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Mittlere Raumtemp. | 22 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 32.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 170 m² |
Lüftung | Fenster |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Bj. 2017/18. 1,5 Geschoss ohne Keller mit 36,5er Poroton Mauerwerk und 20cm Dämmung in der obersten Geschossdecke. Verglasung 3-fach. |