Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2323 | Sole/Wasser | Nibe F1255-6 PC | 6.0 | 2025 | 167 | 4 | 521.0 | 2904.0 | 1358 | 5.57 | 282.0 | 1611.0 | 725 | 5.71 | 239.0 | 1293.0 | 633 | 5.41 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
2323 | Sole/Wasser | Nibe F1255-6 PC | 6.0 | 2024 | 167 | 4 | 1351.0 | 7709.0 | 1435 | 5.71 | 262.0 | 1524.0 | 5.82 | 183.0 | 1099.0 | 6.01 | 157.0 | 918.0 | 5.85 | 97.0 | 504.0 | 5.20 | 42.0 | 85.0 | 2.02 | 39.0 | 169.0 | 4.33 | 39.0 | 158.0 | 4.05 | 38.0 | 156.0 | 4.11 | 36.0 | 80.0 | 2.22 | 74.0 | 510.0 | 185 | 6.89 | 160.0 | 1108.0 | 540 | 6.93 | 224.0 | 1398.0 | 710 | 6.24 | |||||||||||||||||||||
2323 | Sole/Wasser | Nibe F1255-6 PC | 6.0 | 2023 | 167 | 3 | 1410.0 | 7126.0 | 5.05 | 250.0 | 1274.0 | 5.10 | 219.0 | 1070.0 | 4.89 | 201.0 | 1005.0 | 5.00 | 97.0 | 434.0 | 4.47 | 40.0 | 58.0 | 1.45 | 36.0 | 244.0 | 6.78 | 39.0 | 165.0 | 4.23 | 40.0 | 143.0 | 3.58 | 36.0 | 126.0 | 3.50 | 68.0 | 335.0 | 4.93 | 152.0 | 944.0 | 6.21 | 232.0 | 1328.0 | 5.72 | |||||||||||||||||||||||||
2323 | Sole/Wasser | Nibe F1255-6 PC | 6.0 | 2022 | 167 | 3 | 1406.0 | 6882.0 | 1889 | 4.89 | 280.0 | 1440.0 | 718 | 5.14 | 226.0 | 1109.0 | 4.91 | 158.0 | 732.0 | 4.63 | 111.0 | 498.0 | 4.49 | 41.0 | 67.0 | 1.63 | 39.0 | 150.0 | 3.85 | 37.0 | 170.0 | 4.59 | 39.0 | 284.0 | 7.28 | 34.0 | 49.0 | 1.44 | 51.0 | 169.0 | 3.31 | 130.0 | 794.0 | 435 | 6.11 | 260.0 | 1420.0 | 736 | 5.46 | |||||||||||||||||||||
2323 | Sole/Wasser | Nibe F1255-6 PC | 6.0 | 2021 | 167 | 3 | 1692.0 | 8478.0 | 4101 | 5.01 | 314.0 | 1585.0 | 744 | 5.05 | 280.0 | 1315.0 | 586 | 4.70 | 217.0 | 1106.0 | 658 | 5.10 | 136.0 | 679.0 | 385 | 4.99 | 61.0 | 201.0 | 87 | 3.30 | 43.0 | 304.0 | 21 | 7.07 | 40.0 | 210.0 | 18 | 5.25 | 37.0 | 56.0 | 13 | 1.51 | 37.0 | 59.0 | 16 | 1.59 | 86.0 | 480.0 | 254 | 5.58 | 170.0 | 1016.0 | 587 | 5.98 | 271.0 | 1467.0 | 732 | 5.41 | ||||||||||||
2323 | Sole/Wasser | Nibe F1255-6 PC | 6.0 | 2020 | 167 | 3 | 1473.0 | 7854.0 | 3917 | 5.33 | 264.0 | 1437.0 | 736 | 5.44 | 223.0 | 1197.0 | 680 | 5.37 | 192.0 | 1043.0 | 626 | 5.43 | 80.0 | 337.0 | 155 | 4.21 | 50.0 | 147.0 | 55 | 2.94 | 40.0 | 218.0 | 19 | 5.45 | 39.0 | 102.0 | 16 | 2.62 | 41.0 | 345.0 | 18 | 8.41 | 42.0 | 114.0 | 39 | 2.71 | 103.0 | 619.0 | 328 | 6.01 | 148.0 | 882.0 | 509 | 5.96 | 251.0 | 1413.0 | 736 | 5.63 | ||||||||||||
2323 | Sole/Wasser | Nibe F1255-6 PC | 6.0 | 2019 | 167 | 2 | 1622.6 | 8552.0 | 4029 | 5.27 | 328.0 | 1701.0 | 630 | 5.19 | 236.0 | 1122.0 | 610 | 4.75 | 212.0 | 1066.0 | 652 | 5.03 | 95.0 | 387.0 | 250 | 4.07 | 68.0 | 268.0 | 151 | 3.94 | 39.0 | 263.0 | 17 | 6.74 | 38.2 | 262.0 | 13 | 6.86 | 38.4 | 164.0 | 15 | 4.27 | 37.0 | 77.0 | 26 | 2.08 | 91.0 | 539.0 | 276 | 5.92 | 193.0 | 1261.0 | 649 | 6.53 | 247.0 | 1442.0 | 740 | 5.84 | ||||||||||||
2323 | Sole/Wasser | Nibe F1255-6 PC | 6.0 | 2018 | 167 | 2 | 399.0 | 2391.0 | 1700 | 5.99 | 150.0 | 1000.0 | 700 | 6.67 | 249.0 | 1391.0 | 1000 | 5.59 |
NR | 2323 |
Username | Rage |
Einbaujahr der WP | 2018-10-08 |
PLZ des Wohnortes | 48488 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Nibe F1255-6 PC |
modulierend | Ja |
Leistung (0/35) | 6.0 kW |
berechneter Primärenergiebedarf | 32.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 44 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Grabenkollektor |
Tiefe | 1.7 m |
Fläche | 80 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt DB |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | extern > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | intern |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 30.0 °C |
Spreizung Heizkr. | 4.0 |
Heizflaeche | 167 m² |
Lüftung | zenKWLWR |
Personen | 4 |
Grabenkollektor Helfer | Ja |
Grabenkollektor Erfahrung | 2x |
Bemerkungen | HTD RGK mit Planung über HTD-Forum Estrichausheizung in 10-2018 KFW55 Haus Achtung: Kühlung in WMZ enthalten! |