| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 2348 | Luft/Wasser | Buderus WPLS 11.2 RT | 9.1 | 2020 | 150 | 3 | 2906.3 | * | 987 | 634.7 | 233 | 660.8 | 232 | 547.3 | 180 | 522.3 | 172 | 237.1 | 73 | 82.1 | 18 | 82.1 | 18 | 67.8 | 16 | 72.1 | 13 | 32 | ||||||||||||||||||||||||||||||||||||||||||
| 2348 | Luft/Wasser | Buderus WPLS 11.2 RT | 9.1 | 2019 | 150 | 3 | 4451.5 | * | 481 | 842.0 | 604.3 | 525.5 | 335.1 | 289.2 | 78.0 | 80.1 | 25 | 86.1 | 13 | 143.1 | 41 | 284.1 | 96 | 592.0 | 96 | 592.0 | 210 | |||||||||||||||||||||||||||||||||||||||||||
| 2348 | Luft/Wasser | Buderus WPLS 11.2 RT | 9.1 | 2018 | 150 | 3 | 4480.7 | * | 638.1 | 879.6 | 648.8 | 255.7 | 137.2 | 79.4 | 64.8 | 79.6 | 158.4 | 321.0 | 565.1 | 653.0 | ||||||||||||||||||||||||||||||||||||||||||||||||||
| 2348 | Luft/Wasser | Buderus WPLS 11.2 RT | 9.1 | 2017 | 150 | 3 | 4401.4 | * | 1076.0 | 635.0 | 409.0 | 151.0 | 398.0 | 87.0 | 39.0 | 75.0 | 147.9 | 258.4 | 547.6 | 577.5 |
| NR | 2348 |
| Username | Glotzkowski |
| Einbaujahr der WP | 2016-11-06 |
| PLZ des Wohnortes | 52249 |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | Buderus WPLS 11.2 RT |
| modulierend | Ja |
| Leistung (0/35) | 9.1 kW |
| berechneter Primärenergiebedarf | 78.0 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 44 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | Nein (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | FBH |
| elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
| elektr. Verbrauch HP gem./DB | 0 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | > erfasst: |
| WMZ | |
| Mittlere Raumtemp. | 21.0 °C |
| Mittlere Wärmequellentemperatur | 0.0 °C |
| Heizung max. Vorlauf Temp. | 42.0 °C |
| Spreizung Heizkr. | 0.0 |
| Heizflaeche | 150 m² |
| Lüftung | Fenster |
| Personen | 3 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen |