Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2358 | Sole/Wasser | Nibe F1155-6 | 6.0 | 2024 | 140 | 1 | 952.2 | 5458.0 | 2533 | 5.73 | 235.0 | 1565.0 | 709 | 6.66 | 195.0 | 1220.0 | 405 | 6.26 | 216.0 | 1310.0 | 795 | 6.06 | 139.0 | 851.0 | 374 | 6.12 | 32.3 | 96.0 | 50 | 2.97 | 31.5 | 92.9 | 46 | 2.95 | 24.6 | 37.5 | 28 | 1.52 | 31.3 | 43.3 | 26 | 1.38 | 47.5 | 242.3 | 100 | 5.10 | ||||||||||||||||||||||||
2358 | Sole/Wasser | Nibe F1155-6 | 6.0 | 2023 | 140 | 1 | 1337.3 | 8031.4 | 3865 | 6.01 | 187.0 | 1128.0 | 686 | 6.03 | 177.0 | 1129.0 | 650 | 6.38 | 220.0 | 1349.0 | 592 | 6.13 | 149.1 | 885.3 | 350 | 5.94 | 70.0 | 362.0 | 161 | 5.17 | 30.0 | 42.0 | 12 | 1.40 | 29.7 | 38.7 | 12 | 1.30 | 32.0 | 43.0 | 14 | 1.34 | 27.0 | 53.0 | 51 | 1.96 | 77.0 | 566.0 | 251 | 7.35 | 140.3 | 1053.0 | 443 | 7.51 | 198.2 | 1382.4 | 643 | 6.97 | ||||||||||||
2358 | Sole/Wasser | Nibe F1155-6 | 6.0 | 2022 | 140 | 1 | 1651.4 | 9525.5 | 4323 | 5.77 | 283.1 | 1834.0 | 764 | 6.48 | 276.0 | 1690.5 | 687 | 6.13 | 255.3 | 1363.0 | 519 | 5.34 | 198.1 | 1060.1 | 414 | 5.35 | 84.8 | 436.8 | 197 | 5.15 | 43.1 | 144.6 | 70 | 3.35 | 31.0 | 49.8 | 41 | 1.61 | 22.1 | 39.8 | 47 | 1.80 | 49.9 | 306.0 | 179 | 6.13 | 74.3 | 473.4 | 229 | 6.37 | 130.7 | 872.5 | 455 | 6.68 | 203.0 | 1255.0 | 721 | 6.18 | ||||||||||||
2358 | Sole/Wasser | Nibe F1155-6 | 6.0 | 2021 | 140 | 1 | 2073.9 | 12735.7 | 4798 | 6.14 | 349.1 | 2183.3 | 768 | 6.25 | 306.6 | 1786.3 | 657 | 5.83 | 250.9 | 1555.8 | 750 | 6.20 | 216.1 | 1285.4 | 441 | 5.95 | 175.9 | 1061.6 | 348 | 6.04 | 28.7 | 57.0 | 31 | 1.99 | 26.0 | 48.0 | 26 | 1.85 | 35.0 | 116.0 | 53 | 3.31 | 57.0 | 311.0 | 116 | 5.46 | 134.0 | 950.0 | 336 | 7.09 | 193.4 | 1388.7 | 536 | 7.18 | 301.2 | 1992.6 | 736 | 6.62 | ||||||||||||
2358 | Sole/Wasser | Nibe F1155-6 | 6.0 | 2020 | 140 | 1 | 1701.5 | 10954.9 | 4830 | 6.44 | 267.6 | 1730.1 | 750 | 6.47 | 214.8 | 1388.6 | 649 | 6.46 | 165.9 | 1015.5 | 497 | 6.12 | 178.8 | 1039.5 | 363 | 5.81 | 132.8 | 836.9 | 315 | 6.30 | 37.6 | 154.0 | 134 | 4.10 | 35.2 | 152.4 | 127 | 4.33 | 25.8 | 55.4 | 67 | 2.15 | 64.7 | 448.4 | 214 | 6.93 | 128.1 | 982.8 | 404 | 7.67 | 176.2 | 1292.6 | 560 | 7.34 | 274.0 | 1858.7 | 750 | 6.78 | ||||||||||||
2358 | Sole/Wasser | Nibe F1155-6 | 6.0 | 2019 | 140 | 1 | 1333.7 | 8356.6 | 3908 | 6.27 | 74.1 | 357.0 | 126 | 4.82 | 240.6 | 1294.7 | 615 | 5.38 | 177.9 | 1182.8 | 670 | 6.65 | 114.6 | 669.4 | 274 | 5.84 | 79.2 | 514.0 | 238 | 6.49 | 20.0 | 32.0 | 68 | 1.60 | 23.5 | 60.1 | 11 | 2.56 | 4.7 | 10.3 | 8 | 2.19 | 47.4 | 283.8 | 155 | 5.99 | 118.4 | 885.9 | 427 | 7.48 | 189.7 | 1391.2 | 606 | 7.33 | 243.6 | 1675.4 | 710 | 6.88 |
NR | 2358 |
Username | lars |
Einbaujahr der WP | 2019-01-27 |
PLZ des Wohnortes | 21640 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Nibe F1155-6 |
modulierend | Ja |
Leistung (0/35) | 6.0 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 45 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Grabenkollektor |
Tiefe | 1.5 m |
Fläche | 130 m² |
Heizungsart | FBH und Wandheizung |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 14 Watt |
elektr. Verbrauch WQ P gem./DB | 8 Watt |
Stromzähler | extern > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | intern |
Mittlere Raumtemp. | 20.0 °C |
Mittlere Wärmequellentemperatur | 6.0 °C |
Heizung max. Vorlauf Temp. | 32.0 °C |
Spreizung Heizkr. | 5.0 |
Heizflaeche | 140 m² |
Lüftung | zenKWLWR |
Personen | 1 |
Grabenkollektor Helfer | Ja |
Grabenkollektor Erfahrung | Eigenen RGK verlegt. |
Bemerkungen | Sanierter Altbau BJ 1909 45-50% des Stromverbrauchs der WP gedeckt mit 9,99kWp PV-Anlage WNW 20°DN |