Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2418 | Sole/Wasser | Alpha Innotec SCW 82 HK3 | 7.7 | 2024 | 172 | 4 | 1772.0 | 7722.0 | 856 | 4.36 | 430.0 | 2000.0 | 225 | 4.65 | 284.0 | 1336.0 | 147 | 4.70 | 271.0 | 1149.0 | 124 | 4.24 | 74.0 | 309.0 | 33 | 4.18 | 80.0 | 264.0 | 28 | 3.30 | 73.0 | 282.0 | 50 | 3.86 | 75.0 | 270.0 | 27 | 3.60 | 51.0 | 181.0 | 17 | 3.55 | 68.0 | 258.0 | 27 | 3.79 | 59.0 | 228.0 | 23 | 3.86 | 307.0 | 1445.0 | 155 | 4.71 | ||||||||||||||||
2418 | Sole/Wasser | Alpha Innotec SCW 82 HK3 | 7.7 | 2023 | 172 | 4 | 2304.0 | 9971.0 | 1089 | 4.33 | 396.0 | 1803.0 | 203 | 4.55 | 325.0 | 1450.0 | 163 | 4.46 | 299.0 | 1307.0 | 146 | 4.37 | 167.0 | 696.0 | 77 | 4.17 | 92.0 | 328.0 | 34 | 3.57 | 79.0 | 293.0 | 30 | 3.71 | 65.0 | 236.0 | 23 | 3.63 | 76.0 | 283.0 | 28 | 3.72 | 67.0 | 209.0 | 22 | 3.12 | 97.0 | 388.0 | 40 | 4.00 | 277.0 | 1292.0 | 137 | 4.66 | 364.0 | 1686.0 | 186 | 4.63 | ||||||||||||
2418 | Sole/Wasser | Alpha Innotec SCW 82 HK3 | 7.7 | 2022 | 172 | 4 | 2169.0 | 9408.0 | 1031 | 4.34 | 412.0 | 1878.0 | 213 | 4.56 | 323.0 | 1473.0 | 166 | 4.56 | 236.0 | 1017.0 | 114 | 4.31 | 144.0 | 568.0 | 63 | 3.94 | 79.0 | 323.0 | 33 | 4.09 | 67.0 | 230.0 | 24 | 3.43 | 128.0 | 474.0 | 48 | 3.70 | 51.0 | 215.0 | 21 | 4.22 | 65.0 | 233.0 | 23 | 3.58 | 64.0 | 253.0 | 26 | 3.95 | 218.0 | 991.0 | 104 | 4.55 | 382.0 | 1753.0 | 196 | 4.59 | ||||||||||||
2418 | Sole/Wasser | Alpha Innotec SCW 82 HK3 | 7.7 | 2021 | 172 | 4 | 2549.0 | 11215.0 | 1235 | 4.40 | 432.0 | 2000.0 | 227 | 4.63 | 349.0 | 1565.0 | 179 | 4.48 | 282.0 | 1245.0 | 139 | 4.41 | 235.0 | 1021.0 | 114 | 4.34 | 130.0 | 474.0 | 51 | 3.65 | 74.0 | 311.0 | 31 | 4.20 | 79.0 | 301.0 | 30 | 3.81 | 74.0 | 301.0 | 30 | 4.07 | 69.0 | 298.0 | 30 | 4.32 | 166.0 | 689.0 | 72 | 4.15 | 296.0 | 1357.0 | 147 | 4.58 | 363.0 | 1653.0 | 185 | 4.55 | ||||||||||||
2418 | Sole/Wasser | Alpha Innotec SCW 82 HK3 | 7.7 | 2020 | 172 | 3 | 2290.0 | 9747.0 | 1082 | 4.26 | 378.0 | 1678.0 | 191 | 4.44 | 364.0 | 1610.0 | 185 | 4.42 | 288.0 | 1257.0 | 142 | 4.36 | 168.0 | 657.0 | 74 | 3.91 | 115.0 | 326.0 | 36 | 2.83 | 55.0 | 202.0 | 23 | 3.67 | 67.0 | 245.0 | 26 | 3.66 | 48.0 | 213.0 | 21 | 4.44 | 71.0 | 248.0 | 26 | 3.49 | 167.0 | 718.0 | 76 | 4.30 | 221.0 | 993.0 | 106 | 4.49 | 348.0 | 1600.0 | 176 | 4.60 | ||||||||||||
2418 | Sole/Wasser | Alpha Innotec SCW 82 HK3 | 7.7 | 2019 | 172 | 3 | 1448.0 | 6352.0 | 725 | 4.39 | 436.0 | 1646.0 | 205 | 3.78 | 70.0 | 452.0 | 49 | 6.46 | 183.0 | 824.0 | 87 | 4.50 | 362.0 | 1637.0 | 182 | 4.52 | 397.0 | 1793.0 | 202 | 4.52 |
NR | 2418 |
Username | Rafael |
Einbaujahr der WP | 2019-08-04 |
PLZ des Wohnortes | 47918 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Alpha Innotec SCW 82 HK3 |
modulierend | |
Leistung (0/35) | 7.7 kW |
berechneter Primärenergiebedarf | 42.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 49 °C |
WW Legionellenschaltung | |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | 2 Erdbohrungen |
Tiefe | 60.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 1570 Watt DB |
elektr. Verbrauch HP gem./DB | 30 Watt |
elektr. Verbrauch WQ P gem./DB | 70 Watt |
Stromzähler | extern > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | intern |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 4.0 °C |
Heizung max. Vorlauf Temp. | 60.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 172 m² |
Lüftung | zenKWLWR |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Ausheizprogramm gestartet am 14.08.2019 und am 24.08.2019 beendet. Kühlung lief 2020 1268 Stunden. Verbrauch 180W. Insgesamt 240 kWh Strom abgezogen. Kühlung 2021 06/21-10/21 277 kWh Kühlung 2022 06/22-10/22 413 kWh Kühlung 2023 05/23-10/23 228 kWh |