Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2533 | Sole/Wasser | Harreither S-WP-H9S | 8.7 | 2024 | 170 | 4 | 1701.0 | * | 775 | 474.0 | 226 | 387.0 | 184 | 297.0 | 138 | 240.0 | 109 | 114.0 | 46 | 79.0 | 29 | 57.0 | 22 | 53.0 | 21 | |||||||||||||||||||||||||||||||||||||||||||||
2533 | Sole/Wasser | Harreither S-WP-H9S | 8.7 | 2023 | 170 | 4 | 2662.0 | * | 1184 | 464.0 | 213 | 433.0 | 195 | 270.0 | 125 | 263.0 | 120 | 157.0 | 69 | 78.0 | 28 | 60.0 | 22 | 62.0 | 23 | 60.0 | 21 | 117.0 | 49 | 276.0 | 123 | 422.0 | 196 | |||||||||||||||||||||||||||||||||||||
2533 | Sole/Wasser | Harreither S-WP-H9S | 8.7 | 2022 | 170 | 4 | 2890.0 | * | 1302 | 477.0 | 228 | 487.0 | 230 | 369.0 | 176 | 301.0 | 135 | 118.0 | 47 | 96.0 | 35 | 47.0 | 17 | 59.0 | 21 | 101.0 | 40 | 147.0 | 59 | 297.0 | 132 | 391.0 | 182 | |||||||||||||||||||||||||||||||||||||
2533 | Sole/Wasser | Harreither S-WP-H9S | 8.7 | 2021 | 170 | 4 | 3395.0 | * | 1537 | 545.0 | 258 | 433.0 | 206 | 474.0 | 223 | 323.0 | 148 | 287.0 | 129 | 102.0 | 38 | 85.0 | 29 | 84.0 | 29 | 88.0 | 33 | 206.0 | 88 | 295.0 | 132 | 473.0 | 224 | |||||||||||||||||||||||||||||||||||||
2533 | Sole/Wasser | Harreither S-WP-H9S | 8.7 | 2020 | 170 | 4 | 2768.4 | * | 1240 | 454.0 | 214 | 393.0 | 190 | 312.0 | 147 | 196.0 | 85 | 166.4 | 68 | 101.0 | 41 | 84.0 | 30 | 68.0 | 25 | 81.0 | 29 | 207.0 | 91 | 268.0 | 120 | 438.0 | 200 | |||||||||||||||||||||||||||||||||||||
2533 | Sole/Wasser | Harreither S-WP-H9S | 8.7 | 2019 | 170 | 4 | 3176.0 | * | 1478 | 574.0 | 370.0 | 349.0 | 287.0 | 161.0 | 125.0 | 76.0 | 81.0 | 124.0 | 242.0 | 337.0 | 450.0 | 1478 | ||||||||||||||||||||||||||||||||||||||||||||||||
2533 | Sole/Wasser | Harreither S-WP-H9S | 8.7 | 2018 | 170 | 4 | 3415.0 | * | 667.0 | 534.0 | 540.0 | 179.0 | 165.0 | 70.0 | 56.0 | 47.0 | 64.0 | 228.0 | 403.0 | 462.0 |
NR | 2533 |
Username | Melmar |
Einbaujahr der WP | 2017-06-23 |
PLZ des Wohnortes | A |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Harreither S-WP-H9S |
modulierend | Nein |
Leistung (0/35) | 8.7 kW |
berechneter Primärenergiebedarf | 90.8 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 48 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Nein (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Flachkollektoren |
Tiefe | 1.5 m |
Fläche | 300 m² |
Heizungsart | FBH und Wandheizung |
elektr. Verbrauch WP ohne NA gem./DB | 2080 Watt gem. |
elektr. Verbrauch HP gem./DB | 30 Watt |
elektr. Verbrauch WQ P gem./DB | 30 Watt |
Stromzähler | extern > erfasst: Kompressor |
WMZ | |
Mittlere Raumtemp. | 23.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 30.0 °C |
Spreizung Heizkr. | 1.7 |
Heizflaeche | 170 m² |
Lüftung | zenKWLWR |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | 2 Erwachsene, 2 Kinder (Zwillinge 9 Jahre), WW über Pufferspeicher 860 Liter (für Heizung und Warmwasser) mit Frischwassermodul. Maximale VL-Temperatur Heizung wurde auf Werkseinstellung belassen. Bis dato Maximale VL-Temperatur bei -12 Grad AT: 30 Grad. Das Nachrüsten eines WMZ war geplant und wurde mittlerweile verworfen. Flächenkollektor 5 x 100 m. Stromverbrauch nur Kompressor ohne jegliche Hilfsströme. |