Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2545 | Luft/Wasser | IDM TERRA ML 8-13 Complete HGL | 8.2 | 2024 | 175 | 2 | 2874.0 | 13023.0* | 1282 | 4.53 | 859.0 | 3504.0 | 473 | 4.24 | 517.0 | 2509.0 | 278 | 5.12 | 599.0 | 2541.0 | 277 | 4.48 | 324.0 | 1238.0 | 119 | 4.25 | 174.0 | 612.0 | 47 | 4.32 | 109.0 | 334.0 | 22 | 4.35 | 71.0 | 303.0 | 14 | 6.24 | 98.0 | 306.0 | 20 | 4.55 | 123.0 | 416.0 | 32 | 4.52 | ||||||||||||||||||||||||
2545 | Luft/Wasser | IDM TERRA ML 8-13 Complete HGL | 8.2 | 2023 | 175 | 2 | 4854.0 | 21840.0* | 2230 | 4.50 | 734.0 | 3171.0 | 395 | 4.51 | 903.0 | 3671.0 | 409 | 4.22 | 779.0 | 3341.0 | 374 | 4.47 | 457.0 | 1842.0 | 195 | 4.34 | 273.0 | 953.0 | 85 | 4.00 | 100.0 | 304.0 | 20 | 4.44 | 93.0 | 281.0 | 19 | 4.53 | 100.0 | 306.0 | 20 | 4.46 | 95.0 | 291.0 | 19 | 4.54 | 257.0 | 1103.0 | 103 | 4.84 | 443.0 | 2026.0 | 239 | 4.89 | 620.0 | 2871.0 | 352 | 4.86 | ||||||||||||
2545 | Luft/Wasser | IDM TERRA ML 8-13 Complete HGL | 8.2 | 2022 | 175 | 2 | 5264.0 | 22841.0* | 2443 | 4.34 | 751.0 | 3284.0 | 407 | 4.56 | 647.0 | 2803.0 | 327 | 4.55 | 784.0 | 3073.0 | 386 | 4.10 | 536.0 | 2212.0 | 249 | 4.39 | 283.0 | 1056.0 | 96 | 4.23 | 147.0 | 453.0 | 41 | 4.03 | 144.0 | 381.0 | 40 | 3.62 | 114.0 | 313.0 | 28 | 3.97 | 277.0 | 1075.0 | 94 | 4.39 | 271.0 | 1129.0 | 103 | 4.68 | 521.0 | 2284.0 | 265 | 4.65 | 789.0 | 3098.0 | 407 | 4.10 | ||||||||||||
2545 | Luft/Wasser | IDM TERRA ML 8-13 Complete HGL | 8.2 | 2021 | 175 | 2 | 7121.0 | 26060.0* | 2780 | 3.66 | 1314.0 | 3982.0 | 535 | 3.14 | 997.0 | 3192.0 | 404 | 3.34 | 980.0 | 3240.0 | 361 | 3.45 | 856.0 | 2626.0 | 281 | 3.23 | 557.0 | 1826.0 | 161 | 3.53 | 175.0 | 335.0 | 34 | 2.71 | 126.0 | 310.0 | 23 | 3.57 | 20.0 | 371.0 | 29 | 25.55 | 312.0 | 832.0 | 68 | 3.12 | 470.0 | 1937.0 | 189 | 4.42 | 539.0 | 2445.0 | 277 | 4.80 | 775.0 | 3284.0 | 418 | 4.42 | ||||||||||||
2545 | Luft/Wasser | IDM TERRA ML 8-13 Complete HGL | 8.2 | 2020 | 175 | 2 | 8847.0 | 30860.0* | 3167 | 3.49 | 1599.0 | 5333.0 | 611 | 3.42 | 1287.0 | 4292.0 | 489 | 3.44 | 1154.0 | 3247.0 | 369 | 2.94 | 708.0 | 2246.0 | 222 | 3.37 | 601.0 | 1900.0 | 187 | 3.39 | 270.0 | 896.0 | 71 | 3.84 | 275.0 | 711.0 | 54 | 3.09 | 223.0 | 487.0 | 57 | 2.81 | 339.0 | 1268.0 | 107 | 4.15 | 685.0 | 2274.0 | 211 | 3.52 | 770.0 | 2971.0 | 347 | 4.04 | 936.0 | 3555.0 | 442 | 3.95 | ||||||||||||
2545 | Luft/Wasser | IDM TERRA ML 8-13 Complete HGL | 8.2 | 2019 | 175 | 2 | 11216.0 | 39081.0* | 3969 | 3.48 | 1887.0 | 6293.0 | 728 | 3.41 | 1310.0 | 4367.0 | 453 | 3.44 | 844.0 | 2814.0 | 260 | 3.50 | 1081.0 | 3604.0 | 333 | 3.46 | 968.0 | 3228.0 | 295 | 3.48 | 127.0 | 425.0 | 32 | 4.45 | 270.0 | 901.0 | 97 | 3.86 | 211.0 | 705.0 | 70 | 4.00 | 592.0 | 1976.0 | 196 | 3.57 | 1108.0 | 3694.0 | 407 | 3.46 | 1416.0 | 4721.0 | 544 | 3.43 | 1402.0 | 4673.0 | 554 | 3.43 |
NR | 2545 |
Username | Mathias95 |
Einbaujahr der WP | 2018-12-21 |
PLZ des Wohnortes | 07570 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Bi |
Hersteller Typ | IDM TERRA ML 8-13 Complete HGL |
modulierend | |
Leistung (0/35) | 8.2 kW |
berechneter Primärenergiebedarf | 43.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 50 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Nein (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 2 Watt DB |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | intern > erfasst: |
WMZ | intern |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 38.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 175 m² |
Lüftung | Fenster |
Personen | 3 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Bezug 02/2019 Ytong-Bau, 175m2 WF zzgl.80m2 Garage beheizt auf 8Grad min., Navigatorsteuerung, PV 9,2KWp, SMA Wechselrichter, Bungalow ohne Keller |