Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2569 | Sole/Wasser | NOVELAN WSV 6.2H3M | 3.3 | 2025 | 115 | 1 | 857.0 | 4175.0 | 1409 | 4.87 | 422.0 | 2111.0 | 718 | 5.00 | 435.0 | 2064.0 | 691 | 4.74 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
2569 | Sole/Wasser | NOVELAN WSV 6.2H3M | 3.3 | 2024 | 115 | 1 | 2779.0 | 14654.0 | 6011 | 5.27 | 399.0 | 2178.0 | 735 | 5.46 | 314.0 | 1714.0 | 692 | 5.46 | 309.0 | 1650.0 | 679 | 5.34 | 248.0 | 1335.0 | 584 | 5.38 | 151.0 | 829.0 | 412 | 5.49 | 108.0 | 542.0 | 263 | 5.02 | 76.0 | 329.0 | 154 | 4.33 | 61.0 | 200.0 | 85 | 3.28 | 123.0 | 666.0 | 343 | 5.41 | 225.0 | 1301.0 | 666 | 5.78 | 333.0 | 1796.0 | 628 | 5.39 | 432.0 | 2114.0 | 770 | 4.89 | ||||||||||||
2569 | Sole/Wasser | NOVELAN WSV 6.2H3M | 3.3 | 2023 | 115 | 1 | 2834.0 | 14541.0 | 5715 | 5.13 | 445.0 | 2248.0 | 773 | 5.05 | 377.0 | 1859.0 | 626 | 4.93 | 322.0 | 1646.0 | 609 | 5.11 | 298.0 | 1598.0 | 671 | 5.36 | 162.0 | 897.0 | 429 | 5.54 | 80.0 | 351.0 | 168 | 4.39 | 60.0 | 242.0 | 115 | 4.03 | 82.0 | 397.0 | 200 | 4.84 | 81.0 | 361.0 | 178 | 4.46 | 191.0 | 1123.0 | 555 | 5.88 | 337.0 | 1802.0 | 685 | 5.35 | 399.0 | 2017.0 | 706 | 5.06 | ||||||||||||
2569 | Sole/Wasser | NOVELAN WSV 6.2H3M | 3.3 | 2022 | 115 | 1 | 2970.0 | 14905.0 | 5831 | 5.02 | 430.0 | 2104.0 | 699 | 4.89 | 380.0 | 1871.0 | 633 | 4.92 | 354.0 | 1974.0 | 704 | 5.58 | 345.0 | 1571.0 | 630 | 4.55 | 163.0 | 854.0 | 385 | 5.24 | 72.0 | 312.0 | 144 | 4.33 | 68.0 | 307.0 | 143 | 4.51 | 96.0 | 232.0 | 100 | 2.42 | 175.0 | 960.0 | 464 | 5.49 | 182.0 | 1042.0 | 535 | 5.73 | 314.0 | 1728.0 | 704 | 5.50 | 391.0 | 1950.0 | 690 | 4.99 | ||||||||||||
2569 | Sole/Wasser | NOVELAN WSV 6.2H3M | 3.3 | 2021 | 115 | 1 | 3211.0 | 15856.0 | 5873 | 4.94 | 504.0 | 2345.0 | 713 | 4.65 | 427.0 | 1955.0 | 624 | 4.58 | 399.0 | 1960.0 | 681 | 4.91 | 318.0 | 1678.0 | 653 | 5.28 | 284.0 | 1491.0 | 680 | 5.25 | 41.0 | 64.0 | 19 | 1.56 | 35.0 | 62.0 | 18 | 1.77 | 92.0 | 436.0 | 199 | 4.74 | 110.0 | 556.0 | 261 | 5.05 | 231.0 | 1339.0 | 625 | 5.80 | 367.0 | 2002.0 | 759 | 5.46 | 403.0 | 1968.0 | 641 | 4.88 | ||||||||||||
2569 | Sole/Wasser | NOVELAN WSV 6.2H3M | 3.3 | 2020 | 115 | 1 | 5185.0 | 8936.9 | 3089 | 4.78 | 669.0 | 910.0 | 1087.0 | 650.0 | 481.0 | 1882.0 | 487 | 3.91 | 206.0 | 1057.4 | 356 | 5.13 | 86.0 | 306.5 | 78 | 3.56 | 38.0 | 31.0 | 9 | 0.82 | 81.0 | 368.0 | 141 | 4.54 | 249.0 | 1492.0 | 680 | 5.99 | 284.0 | 1574.0 | 609 | 5.54 | 444.0 | 2226.0 | 729 | 5.01 |
NR | 2569 |
Username | Wolfman |
Einbaujahr der WP | 2019-03-01 |
PLZ des Wohnortes | 95485 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | NOVELAN WSV 6.2H3M |
modulierend | Ja |
Leistung (0/35) | 3.3 kW |
berechneter Primärenergiebedarf | 59.4 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 48 °C |
WW Legionellenschaltung | wöchentlich |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | 1 Erdbohrung |
Tiefe | 115.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | intern |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 3.0 °C |
Heizung max. Vorlauf Temp. | 0.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 115 m² |
Lüftung | Fenster |
Personen | 1 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | 02.10.2020 Beginn Heizphase Langer Winter 2020/2021. Außergewöhnlich kalter Mai 2021.Ende Heizphase 31.05.2021. Geringer Heizbedarf 09+10/2022 wegen Wetter. Kalter April 2023. 2024 Normaler Jahreszeitenverlauf. Kalter FEB 2025. |