Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
257 | Sole/Wasser | Vaillant VWS 101/2 | 10.4 | 2013 | 180 | 2 | 1224.0 | 3823.0 | 367 | 3.12 | 1224.0 | 3823.0 | 367 | 3.12 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
257 | Sole/Wasser | Vaillant VWS 101/2 | 10.4 | 2012 | 180 | 2 | 7833.0 | 24722.0 | 1997 | 3.16 | 1124.0 | 3592.0 | 336 | 3.20 | 1298.0 | 3907.0 | 388 | 3.01 | 731.0 | 2362.0 | 210 | 3.23 | 670.0 | 2165.0 | 191 | 3.23 | 381.0 | 1173.0 | 94 | 3.08 | 348.0 | 1057.0 | 82 | 3.04 | 248.0 | 712.0 | 51 | 2.87 | 219.0 | 601.0 | 43 | 2.74 | 352.0 | 1090.0 | 83 | 3.10 | 630.0 | 2074.0 | 174 | 3.29 | 784.0 | 2608.0 | 32 | 3.33 | 1048.0 | 3381.0 | 313 | 3.23 | ||||||||||||
257 | Sole/Wasser | Vaillant VWS 101/2 | 10.4 | 2011 | 180 | 4 | 7296.0 | 23054.0 | 2042 | 3.16 | 1084.0 | 3454.0 | 327 | 3.19 | 1070.0 | 3362.0 | 322 | 3.14 | 947.0 | 3010.0 | 282 | 3.18 | 524.0 | 1620.0 | 137 | 3.09 | 348.0 | 1060.0 | 85 | 3.05 | 252.0 | 739.0 | 56 | 2.93 | 260.0 | 763.0 | 58 | 2.93 | 229.0 | 678.0 | 49 | 2.96 | 273.0 | 831.0 | 62 | 3.04 | 493.0 | 1626.0 | 133 | 3.30 | 814.0 | 2655.0 | 233 | 3.26 | 1002.0 | 3256.0 | 298 | 3.25 | ||||||||||||
257 | Sole/Wasser | Vaillant VWS 101/2 | 10.4 | 2010 | 180 | 4 | 9229.0 | 28181.0 | 2503 | 3.05 | 1562.0 | 5104.0 | 503 | 3.27 | 1245.0 | 4136.0 | 402 | 3.32 | 987.0 | 3314.0 | 307 | 3.36 | 650.0 | 2196.0 | 187 | 3.38 | 536.0 | 1730.0 | 141 | 3.23 | 326.0 | 758.0 | 50 | 2.33 | 258.0 | 451.0 | 21 | 1.75 | 324.0 | 608.0 | 29 | 1.88 | 393.0 | 983.0 | 67 | 2.50 | 661.0 | 1918.0 | 149 | 2.90 | 833.0 | 2527.0 | 212 | 3.03 | 1454.0 | 4456.0 | 435 | 3.06 | ||||||||||||
257 | Sole/Wasser | Vaillant VWS 101/2 | 10.4 | 2009 | 180 | 4 | 2443.0 | 8181.0 | 724 | 3.35 | 641.0 | 2168.0 | 185 | 3.38 | 678.0 | 2282.0 | 194 | 3.37 | 1124.0 | 3731.0 | 345 | 3.32 |
NR | 257 |
Username | Toni |
Einbaujahr der WP | 2009-09-01 |
PLZ des Wohnortes | 38685 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Vaillant VWS 101/2 |
modulierend | |
Leistung (0/35) | 10.4 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 42 °C |
WW Legionellenschaltung | Ja |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | 2 Erdbohrungen |
Tiefe | 80.0 m |
Fläche | 0 m² |
Heizungsart | FBH und Radiatoren |
elektr. Verbrauch WP ohne NA gem./DB | 2400 Watt gem. |
elektr. Verbrauch HP gem./DB | 120 Watt |
elektr. Verbrauch WQ P gem./DB | 50 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 4.0 °C |
Heizung max. Vorlauf Temp. | 42.0 °C |
Spreizung Heizkr. | 7.0 |
Heizflaeche | 180 m² |
Lüftung | Fenster |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen |