Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2616 | Sole/Wasser | NIBE F1255-6 R EM PC | 6.0 | 2023 | 228 | 3 | 1765.0 | 8282.0 | 3495 | 4.69 | 422.0 | 2091.0 | 741 | 4.95 | 312.0 | 1540.0 | 636 | 4.94 | 298.0 | 1454.0 | 706 | 4.88 | 269.0 | 1311.0 | 653 | 4.87 | 118.0 | 556.0 | 268 | 4.71 | 65.0 | 160.0 | 40 | 2.46 | 55.0 | 137.0 | 36 | 2.49 | 59.0 | 156.0 | 41 | 2.64 | 57.0 | 195.0 | 62 | 3.42 | 110.0 | 682.0 | 312 | 6.20 | ||||||||||||||||||||
2616 | Sole/Wasser | NIBE F1255-6 R EM PC | 6.0 | 2022 | 228 | 3 | 2371.0 | 11754.0 | 4931 | 4.96 | 416.0 | 2029.0 | 748 | 4.88 | 368.0 | 1793.0 | 665 | 4.87 | 335.0 | 1615.0 | 744 | 4.82 | 255.0 | 1234.0 | 632 | 4.84 | 93.0 | 362.0 | 140 | 3.89 | 63.0 | 158.0 | 39 | 2.51 | 52.0 | 116.0 | 31 | 2.23 | 51.0 | 121.0 | 31 | 2.37 | 68.0 | 436.0 | 218 | 6.41 | 109.0 | 655.0 | 329 | 6.01 | 214.0 | 1346.0 | 623 | 6.29 | 347.0 | 1889.0 | 731 | 5.44 | ||||||||||||
2616 | Sole/Wasser | NIBE F1255-6 R EM PC | 6.0 | 2021 | 228 | 3 | 2656.0 | 12869.0 | 5203 | 4.85 | 493.0 | 2260.0 | 706 | 4.58 | 383.0 | 1752.0 | 671 | 4.57 | 331.0 | 1559.0 | 691 | 4.71 | 264.0 | 1234.0 | 550 | 4.67 | 167.0 | 779.0 | 380 | 4.66 | 64.0 | 157.0 | 39 | 2.45 | 55.0 | 137.0 | 35 | 2.49 | 62.0 | 220.0 | 75 | 3.55 | 80.0 | 502.0 | 248 | 6.28 | 128.0 | 753.0 | 374 | 5.88 | 252.0 | 1548.0 | 709 | 6.14 | 377.0 | 1968.0 | 725 | 5.22 | ||||||||||||
2616 | Sole/Wasser | NIBE F1255-6 R EM PC | 6.0 | 2020 | 228 | 3 | 1045.0 | 5531.0 | 2068 | 5.29 | 240.0 | 1400.0 | 600 | 5.83 | 299.0 | 1750.0 | 710 | 5.85 | 506.0 | 2381.0 | 758 | 4.71 |
NR | 2616 |
Username | supapeda |
Einbaujahr der WP | 2019-12-20 |
PLZ des Wohnortes | A-6306 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | NIBE F1255-6 R EM PC |
modulierend | Ja |
Leistung (0/35) | 6.0 kW |
berechneter Primärenergiebedarf | 35.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 46 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Grabenkollektor |
Tiefe | 1.7 m |
Fläche | 0 m² |
Heizungsart | FBH und Wandheizung |
elektr. Verbrauch WP ohne NA gem./DB | 660 Watt DB |
elektr. Verbrauch HP gem./DB | 2 Watt |
elektr. Verbrauch WQ P gem./DB | 10 Watt |
Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | intern |
Mittlere Raumtemp. | 23.0 °C |
Mittlere Wärmequellentemperatur | 2.0 °C |
Heizung max. Vorlauf Temp. | 31.0 °C |
Spreizung Heizkr. | 3.0 |
Heizflaeche | 228 m² |
Lüftung | zenKWLWR |
Personen | 3 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | Nur eigene Verlegung |
Bemerkungen | Grabenkollektor und Baugrubenkollektor Neubau- Estrich Ausheizen 12/19-01/20 Erfassung Start nach 11500kWh Wärme in 10/2020 |