Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2623 | Luft/Wasser | Chofu - AEYC-1642XU3 | 16.0 | 2023 | 200 | 4101.0 | * | 1025.0 | 980.0 | 722.0 | 571.0 | 338.0 | 197.0 | 268.0 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2623 | Luft/Wasser | Chofu - AEYC-1642XU3 | 16.0 | 2022 | 200 | 2 | 6536.0 | * | 1374.0 | 715.0 | 691.0 | 244.0 | 220.0 | 265.0 | 226.0 | 235.0 | 125.0 | 349.0 | 783.0 | 1309.0 | ||||||||||||||||||||||||||||||||||||||||||||||||||
2623 | Luft/Wasser | Chofu - AEYC-1642XU3 | 16.0 | 2021 | 200 | 2 | 9074.0 | * | 1663.0 | 1397.0 | 1153.0 | 689.0 | 372.0 | 244.0 | 270.0 | 239.0 | 203.0 | 542.0 | 920.0 | 1382.0 | ||||||||||||||||||||||||||||||||||||||||||||||||||
2623 | Luft/Wasser | Chofu - AEYC-1642XU3 | 16.0 | 2020 | 200 | 2 | 7889.6 | * | 1664.0 | 1006.0 | 851.0 | 376.0 | 295.0 | 168.0 | 277.0 | 232.6 | 210.0 | 477.0 | 974.0 | 1359.0 | ||||||||||||||||||||||||||||||||||||||||||||||||||
2623 | Luft/Wasser | Chofu - AEYC-1642XU3 | 16.0 | 2019 | 200 | 2 | 2940.0 | * | 225.0 | 236.0 | 478.0 | 700.0 | 1301.0 |
NR | 2623 |
Username | JPS77 |
Einbaujahr der WP | 2019-08-01 |
PLZ des Wohnortes | A-2231 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Chofu - AEYC-1642XU3 |
modulierend | Ja |
Leistung (0/35) | 16.0 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 49 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Nein (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 99.9 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 0.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 200 m² |
Lüftung | Fenster |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Gebäude letzte Sanierung 1990 (Fenster ,Wärmedämmung 5cm) Im Sommer wird mit Wärmepumpe gekühlt. |