Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2674 | Luft/Wasser | Alpha Innotec LWDV91-12-3 | 8.2 | 2024 | 140 | 2 | 2443.2 | 10108.4 | 2650 | 4.14 | 616.4 | 2359.0 | 623 | 3.83 | 350.0 | 1603.0 | 430 | 4.58 | 333.0 | 1528.0 | 398 | 4.59 | 239.0 | 1055.0 | 282 | 4.41 | 74.0 | 259.0 | 49 | 3.50 | 47.8 | 114.4 | 18 | 2.39 | 46.0 | 100.0 | 15 | 2.17 | 44.0 | 92.0 | 14 | 2.09 | 87.0 | 308.0 | 67 | 3.54 | 205.0 | 957.0 | 211 | 4.67 | 401.0 | 1733.0 | 543 | 4.32 | ||||||||||||||||
2674 | Luft/Wasser | Alpha Innotec LWDV91-12-3 | 8.2 | 2023 | 140 | 2 | 2929.0 | 12060.0 | 3172 | 4.12 | 522.0 | 2132.0 | 595 | 4.08 | 444.0 | 1814.0 | 542 | 4.09 | 394.0 | 1703.0 | 443 | 4.32 | 288.0 | 1281.0 | 308 | 4.45 | 79.0 | 263.0 | 45 | 3.33 | 48.0 | 105.0 | 15 | 2.19 | 46.0 | 94.0 | 15 | 2.04 | 44.0 | 92.0 | 14 | 2.09 | 44.0 | 97.0 | 15 | 2.20 | 172.0 | 796.0 | 167 | 4.63 | 376.0 | 1673.0 | 455 | 4.45 | 472.0 | 2010.0 | 558 | 4.26 | ||||||||||||
2674 | Luft/Wasser | Alpha Innotec LWDV91-12-3 | 8.2 | 2022 | 140 | 2 | 2958.9 | 12474.9 | 3563 | 4.22 | 571.0 | 2350.0 | 699 | 4.12 | 411.0 | 1863.0 | 606 | 4.53 | 384.0 | 1728.0 | 536 | 4.50 | 270.0 | 1221.7 | 351 | 4.52 | 74.5 | 252.5 | 54 | 3.39 | 48.4 | 116.0 | 18 | 2.40 | 45.0 | 91.7 | 14 | 2.04 | 46.0 | 91.0 | 14 | 1.98 | 102.0 | 429.0 | 90 | 4.21 | 112.0 | 492.0 | 88 | 4.39 | 333.0 | 1589.0 | 443 | 4.77 | 562.0 | 2251.0 | 650 | 4.01 | ||||||||||||
2674 | Luft/Wasser | Alpha Innotec LWDV91-12-3 | 8.2 | 2021 | 140 | 2 | 3583.2 | 15028.5 | 3640 | 4.19 | 664.0 | 2648.0 | 623 | 3.99 | 504.0 | 2030.0 | 577 | 4.03 | 451.0 | 1939.0 | 4.30 | 343.0 | 1534.0 | 436 | 4.47 | 197.0 | 956.0 | 262 | 4.85 | 49.0 | 124.0 | 19 | 2.53 | 54.0 | 140.0 | 22 | 2.59 | 53.8 | 139.0 | 22 | 2.58 | 57.8 | 168.9 | 28 | 2.92 | 275.9 | 1285.0 | 345 | 4.66 | 433.8 | 1909.7 | 612 | 4.40 | 499.9 | 2154.9 | 694 | 4.31 | |||||||||||||
2674 | Luft/Wasser | Alpha Innotec LWDV91-12-3 | 8.2 | 2020 | 140 | 2 | 2689.0 | 11037.0 | 4.10 | 652.0 | 2509.0 | 3.85 | 455.0 | 1929.6 | 4.24 | 417.0 | 1815.0 | 4.35 | 171.0 | 672.4 | 3.93 | 144.0 | 600.7 | 4.17 | 52.0 | 138.2 | 2.66 | 52.0 | 135.3 | 2.60 | 48.0 | 126.7 | 2.64 | 81.0 | 298.1 | 3.68 | 236.0 | 1143.0 | 4.84 | 381.0 | 1669.0 | 4.38 |
NR | 2674 |
Username | zimka |
Einbaujahr der WP | 2018-12-17 |
PLZ des Wohnortes | 74909 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Alpha Innotec LWDV91-12-3 |
modulierend | Ja |
Leistung (0/35) | 8.2 kW |
berechneter Primärenergiebedarf | 75.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 45 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH und Radiatoren |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 0.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 140 m² |
Lüftung | Fenster |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | freistehendes EF-Haus Bj 1991 Radiatoren sind als Einrohr-System verbaut In der Anfangsphase viele Probleme wie z.B. Vereisung, Abschaltungen p0-pause IO-pause u.a. zu Beginn war die angezeigte Wärmemenge um ca Faktor 2 zu hoch. Durch neuere firmware Fehler beseitigt. durch AI veranlasster Tausch der Inverterplatine. Seit Mitte 2019 keine Fehler mehr |