Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2689 | Luft/Wasser | Elco Aertop Split WH07 | 7.0 | 2024 | 177 | 3 | 1230.0 | * | 431.0 | 159.0 | 123.0 | 65.0 | 33.0 | 30.0 | 26.0 | 25.0 | 81.0 | 257.0 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
2689 | Luft/Wasser | Elco Aertop Split WH07 | 7.0 | 2023 | 177 | 2,5 | 1630.0 | * | 304.0 | 231.0 | 170.0 | 119.0 | 56.0 | 43.0 | 44.0 | 43.0 | 47.0 | 60.0 | 214.0 | 299.0 | ||||||||||||||||||||||||||||||||||||||||||||||||||
2689 | Luft/Wasser | Elco Aertop Split WH07 | 7.0 | 2022 | 177 | 2,5 | 1826.0 | * | 357.0 | 246.0 | 219.0 | 148.0 | 51.0 | 44.0 | 45.0 | 45.0 | 49.0 | 56.0 | 179.0 | 387.0 | ||||||||||||||||||||||||||||||||||||||||||||||||||
2689 | Luft/Wasser | Elco Aertop Split WH07 | 7.0 | 2021 | 177 | 2 | 2208.0 | * | 457.0 | 300.0 | 226.0 | 162.0 | 106.0 | 37.0 | 38.0 | 40.0 | 47.0 | 154.0 | 293.0 | 348.0 | ||||||||||||||||||||||||||||||||||||||||||||||||||
2689 | Luft/Wasser | Elco Aertop Split WH07 | 7.0 | 2020 | 177 | 2 | 791.0 | * | 150.0 | 247.0 | 394.0 |
NR | 2689 |
Username | manuti |
Einbaujahr der WP | 2020-02-28 |
PLZ des Wohnortes | 67227 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Elco Aertop Split WH07 |
modulierend | Ja |
Leistung (0/35) | 7.0 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 48 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Nein (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 0.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 177 m² |
Lüftung | Fenster |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen |