Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2755 | Luft/Wasser | Wolf CHA07 | 7.0 | 2024 | 145 | 5 | 1396.8 | 6466.0 | 4.63 | 357.0 | 1513.0 | 4.24 | 179.0 | 957.0 | 5.35 | 186.0 | 995.0 | 5.35 | 118.8 | 552.0 | 4.65 | 55.0 | 216.0 | 3.93 | 55.0 | 216.0 | 3.93 | 49.0 | 185.0 | 3.78 | 49.0 | 189.0 | 3.86 | 58.0 | 226.0 | 3.90 | 89.0 | 417.0 | 4.69 | 201.0 | 1000.0 | 4.98 | ||||||||||||||||||||||||||||
2755 | Luft/Wasser | Wolf CHA07 | 7.0 | 2023 | 145 | 5 | 1552.0 | 6880.0 | 4.43 | 250.0 | 1053.0 | 4.21 | 212.0 | 939.0 | 4.43 | 263.0 | 1300.0 | 4.94 | 174.0 | 943.0 | 5.42 | 71.0 | 320.0 | 4.51 | 49.0 | 191.0 | 3.90 | 46.0 | 180.0 | 3.91 | 46.0 | 180.0 | 3.91 | 45.0 | 169.0 | 3.76 | 54.0 | 192.0 | 3.56 | 149.0 | 630.0 | 4.23 | 193.0 | 783.0 | 4.06 | |||||||||||||||||||||||||
2755 | Luft/Wasser | Wolf CHA07 | 7.0 | 2022 | 145 | 4 | 1985.5 | 9360.0 | 4.71 | 336.0 | 1710.0 | 5.09 | 286.6 | 1531.0 | 5.34 | 274.0 | 1400.0 | 5.11 | 161.9 | 835.0 | 5.16 | 58.0 | 213.0 | 3.67 | 60.0 | 220.0 | 3.67 | 56.0 | 211.0 | 3.77 | 41.0 | 148.0 | 3.61 | 48.0 | 171.0 | 3.56 | 55.0 | 212.0 | 3.85 | 220.0 | 1104.0 | 5.02 | 389.0 | 1605.0 | 4.13 | |||||||||||||||||||||||||
2755 | Luft/Wasser | Wolf CHA07 | 7.0 | 2021 | 145 | 3 | 1563.7 | 7687.0 | 4.92 | 287.0 | 1455.0 | 5.07 | 194.0 | 1070.0 | 5.52 | 84.0 | 374.0 | 4.45 | 65.0 | 262.0 | 4.03 | 47.0 | 172.0 | 3.66 | 53.0 | 190.0 | 3.58 | 48.0 | 174.0 | 3.63 | 119.0 | 627.0 | 5.27 | 265.0 | 1488.0 | 5.62 | 401.7 | 1875.0 | 4.67 |
NR | 2755 |
Username | CHA07 |
Einbaujahr der WP | 0000-00-00 |
PLZ des Wohnortes | 39240 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Bi |
Hersteller Typ | Wolf CHA07 |
modulierend | Ja |
Leistung (0/35) | 7.0 kW |
berechneter Primärenergiebedarf | 38.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 48 °C |
WW Legionellenschaltung | wöchentlich |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | extern |
Mittlere Raumtemp. | 23.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 31.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 145 m² |
Lüftung | dezKWL |
Personen | 5 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Zirkulationspumpe wird vom Zähler mit erfasst. Die WP ist in Kombi mit einer PV eigenverbrauchsoptimiert. Effizienz daher nicht optimal. 4 kW Kamin wird zusätzlich genutzt. |