Weiterhin alles Gute Michael Schumacher!
| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 2866 | Sole/Wasser | IDM i-pump T 2-8 | 4.1 | 2025 | 110 | 2 | 997.0 | 7353.0 | 2473 | 7.38 | 216.0 | 1606.0 | 535 | 7.44 | 199.0 | 1466.0 | 459 | 7.37 | 132.0 | 1063.0 | 424 | 8.05 | 57.0 | 489.0 | 190 | 8.58 | 14.0 | 123.0 | 47 | 8.79 | 5.0 | 40.0 | 13 | 8.00 | 9.0 | 72.0 | 73 | 8.00 | 22.0 | 106.0 | 19 | 4.82 | 59.0 | 311.0 | 75 | 5.27 | 114.0 | 825.0 | 251 | 7.24 | 170.0 | 1252.0 | 387 | 7.36 | ||||||||||||||||
| 2866 | Sole/Wasser | IDM i-pump T 2-8 | 4.1 | 2024 | 110 | 2 | 1118.3 | 8039.0 | 2901 | 7.19 | 222.0 | 1451.0 | 489 | 6.54 | 138.0 | 1048.0 | 447 | 7.59 | 125.0 | 948.0 | 401 | 7.58 | 75.0 | 571.0 | 222 | 7.61 | 11.0 | 93.0 | 36 | 8.45 | 11.0 | 80.0 | 25 | 7.27 | 8.2 | 67.0 | 66 | 8.17 | 9.6 | 76.0 | 40 | 7.92 | 25.1 | 215.0 | 37 | 8.57 | 76.7 | 745.0 | 266 | 9.71 | 171.0 | 1208.0 | 394 | 7.06 | 245.7 | 1537.0 | 478 | 6.26 | ||||||||||||
| 2866 | Sole/Wasser | IDM i-pump T 2-8 | 4.1 | 2023 | 110 | 2 | 1076.9 | 8382.2 | 3515 | 7.78 | 204.0 | 1544.0 | 652 | 7.57 | 199.0 | 1467.0 | 634 | 7.37 | 166.0 | 1249.0 | 559 | 7.52 | 115.0 | 892.0 | 399 | 7.76 | 29.9 | 238.0 | 105 | 7.96 | 7.0 | 55.0 | 19 | 7.86 | 8.0 | 62.0 | 23 | 7.75 | 9.1 | 68.0 | 30 | 7.47 | 11.5 | 86.1 | 45 | 7.49 | 48.1 | 509.0 | 176 | 10.58 | 110.2 | 947.1 | 386 | 8.59 | 169.1 | 1265.0 | 487 | 7.48 | ||||||||||||
| 2866 | Sole/Wasser | IDM i-pump T 2-8 | 4.1 | 2022 | 110 | 2 | 1592.9 | 11273.0 | 4055 | 7.08 | 327.0 | 2109.0 | 690 | 6.45 | 281.0 | 1825.0 | 640 | 6.49 | 270.4 | 1684.0 | 610 | 6.23 | 179.0 | 1277.0 | 445 | 7.13 | 43.8 | 342.0 | 119 | 7.81 | 6.0 | 50.0 | 17 | 8.33 | 6.3 | 53.0 | 7 | 8.41 | 4.0 | 40.0 | 5 | 10.00 | 55.0 | 487.0 | 145 | 8.85 | 70.0 | 589.0 | 204 | 8.41 | 132.0 | 1142.0 | 491 | 8.65 | 218.4 | 1675.0 | 682 | 7.67 | ||||||||||||
| 2866 | Sole/Wasser | IDM i-pump T 2-8 | 4.1 | 2021 | 110 | 2 | 405.0 | 2741.0 | 843 | 6.77 | 71.0 | 472.0 | 126 | 6.65 | 334.0 | 2269.0 | 717 | 6.79 |
| NR | 2866 |
| Username | UniquX |
| Einbaujahr der WP | 2021-10-01 |
| PLZ des Wohnortes | 63517 |
| Bauart | Sole/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | IDM i-pump T 2-8 |
| modulierend | Ja |
| Leistung (0/35) | 4.1 kW |
| berechneter Primärenergiebedarf | 10.5 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 55 °C |
| WW Legionellenschaltung | Ja |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Grabenkollektor |
| Tiefe | 2.2 m |
| Fläche | 140 m² |
| Heizungsart | FBH |
| elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
| elektr. Verbrauch HP gem./DB | 0 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | extern > erfasst: Kompressor |
| WMZ | intern |
| Mittlere Raumtemp. | 21.0 °C |
| Mittlere Wärmequellentemperatur | 9.0 °C |
| Heizung max. Vorlauf Temp. | 36.0 °C |
| Spreizung Heizkr. | 5.0 |
| Heizflaeche | 110 m² |
| Lüftung | zenKWLWR |
| Personen | 3 |
| Grabenkollektor Helfer | Ja |
| Grabenkollektor Erfahrung | Nach IDM/ Ringgrabenkollektor.at Konzept selbst gelegt. |
| Bemerkungen | RGK (2 Kreise, 140m2) auf ca. 2m x 2,20m Breite/Tiefe komplett in Sickerwasser führenden Schicht (schlupfriger Sand in Hanglage). Drainage wird zum RGK abgeleitet. Berechnete RGK-Leistung 11,8kw. Heizkurve 0,4 Direktheizkreis Ladepumpe 50% WQ-Pumpe 50% Passivkühlung KfW40+ |