Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
2866 | Sole/Wasser | IDM i-pump T 2-8 | 4.1 | 2024 | 110 | 2 | 599.8 | 4334.0 | 1726 | 7.23 | 222.0 | 1451.0 | 489 | 6.54 | 138.0 | 1048.0 | 447 | 7.59 | 125.0 | 948.0 | 401 | 7.58 | 75.0 | 571.0 | 222 | 7.61 | 11.0 | 93.0 | 36 | 8.45 | 11.0 | 80.0 | 25 | 7.27 | 8.2 | 67.0 | 66 | 8.17 | 9.6 | 76.0 | 40 | 7.92 | ||||||||||||||||||||||||||||
2866 | Sole/Wasser | IDM i-pump T 2-8 | 4.1 | 2023 | 110 | 2 | 1076.9 | 8382.2 | 3515 | 7.78 | 204.0 | 1544.0 | 652 | 7.57 | 199.0 | 1467.0 | 634 | 7.37 | 166.0 | 1249.0 | 559 | 7.52 | 115.0 | 892.0 | 399 | 7.76 | 29.9 | 238.0 | 105 | 7.96 | 7.0 | 55.0 | 19 | 7.86 | 8.0 | 62.0 | 23 | 7.75 | 9.1 | 68.0 | 30 | 7.47 | 11.5 | 86.1 | 45 | 7.49 | 48.1 | 509.0 | 176 | 10.58 | 110.2 | 947.1 | 386 | 8.59 | 169.1 | 1265.0 | 487 | 7.48 | ||||||||||||
2866 | Sole/Wasser | IDM i-pump T 2-8 | 4.1 | 2022 | 110 | 2 | 1592.9 | 11273.0 | 4055 | 7.08 | 327.0 | 2109.0 | 690 | 6.45 | 281.0 | 1825.0 | 640 | 6.49 | 270.4 | 1684.0 | 610 | 6.23 | 179.0 | 1277.0 | 445 | 7.13 | 43.8 | 342.0 | 119 | 7.81 | 6.0 | 50.0 | 17 | 8.33 | 6.3 | 53.0 | 7 | 8.41 | 4.0 | 40.0 | 5 | 10.00 | 55.0 | 487.0 | 145 | 8.85 | 70.0 | 589.0 | 204 | 8.41 | 132.0 | 1142.0 | 491 | 8.65 | 218.4 | 1675.0 | 682 | 7.67 | ||||||||||||
2866 | Sole/Wasser | IDM i-pump T 2-8 | 4.1 | 2021 | 110 | 2 | 405.0 | 2741.0 | 843 | 6.77 | 71.0 | 472.0 | 126 | 6.65 | 334.0 | 2269.0 | 717 | 6.79 |
NR | 2866 |
Username | UniquX |
Einbaujahr der WP | 2021-10-01 |
PLZ des Wohnortes | 63517 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | IDM i-pump T 2-8 |
modulierend | Ja |
Leistung (0/35) | 4.1 kW |
berechneter Primärenergiebedarf | 10.5 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 50 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Grabenkollektor |
Tiefe | 2.2 m |
Fläche | 140 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | extern > erfasst: Kompressor |
WMZ | intern |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 9.0 °C |
Heizung max. Vorlauf Temp. | 37.0 °C |
Spreizung Heizkr. | 6.0 |
Heizflaeche | 110 m² |
Lüftung | zenKWLWR |
Personen | 2 |
Grabenkollektor Helfer | Ja |
Grabenkollektor Erfahrung | Nach IDM/ Ringgrabenkollektor.at Konzept selbst gelegt. |
Bemerkungen | RGK (2 Kreise, 140m2) auf ca. 2m x 2,20m Breite/Tiefe komplett in Sickerwasser führenden Schicht (schlupfriger Sand in Hanglage). Drainage wird zum RGK abgeleitet. Berechnete RGK-Leistung 11,8kw. Heizkurve 0,4 Direktheizkreis Ladepumpe 50% WQ-Pumpe 50% Passivkühlung KfW40+ |