Verbrauchsdaten fuer Anlage Nr. 2885
| Jahr | Pers. | GESAMT | Jan | Feb | Mar | Apr | Mai | Jun | Jul | Aug | Sep | Okt | Nov | Dez | ||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | ||
| 2022 | 2 | 3209 | 11612 | 3.62 | 581 | 2113 | 3.64 | 444 | 1654 | 3.73 | 420 | 1535 | 3.65 | 307 | 1152 | 3.75 | 87 | 291 | 3.34 | 45 | 123 | 2.73 | 32 | 42 | 1.31 | 36 | 82 | 2.28 | 70 | 224 | 3.20 | 200 | 765 | 3.83 | 387 | 1478 | 3.82 | 600 | 2153 | 3.59 |
| 2021 | 2 | 4245 | 15952 | 3.76 | 772 | 2627 | 3.40 | 571 | 2002 | 3.51 | 576 | 2120 | 3.68 | 452 | 2398 | 5.31 | 291 | 1152 | 3.96 | 52 | 136 | 2.62 | 40 | 75 | 1.88 | 54 | 139 | 2.57 | 54 | 126 | 2.33 | 280 | 1087 | 3.88 | 504 | 1876 | 3.72 | 599 | 2214 | 3.70 |
Vollständige Anlagendetails
Allgemeine Daten
Anlagen Nr.
2885
Username
Zeller
Gebäude Daten
PLZ
82538
Heizfläche (m²)
196
Wärmeübertragung
FBH
Raumtemperatur (°C)
22.0
Lüftung
Fenster
Endenergiebedarf (kWh/m²/anno)
25.3
berechnet nach Norm
EnEV2016
Wärmepumpe Daten
Hersteller / Typ
NOVELAN LAD 7-CSD
Bauart
Luft/Wasser
Heizleistung (kW) (0/35 2/35)
7.7
Betriebsart Mono/Bi/Tri-valent
Mono
Modulierend
Einbaudatum
2021-01-01
Wärmepumpe Leistungsaufnahme (W)
Umwälzpumpe Leistungsaufnahme (W)
Wärme Quelle & Senke
Quelle
Luft
Tiefe (m)
Fläche (m²)
max. Vorlauftemperatur (°C)
32.0
Spreizung Heizkreise (°K)
4.5
Quellenpumpe Leistungsaufnahme (W)
RGK Helfer
Nein
RGK Erfahrung
Warmwasser
über WP erzeugt
Ja
über WMZ erfasst
Temp (°C)
49
Legionellenschaltung
Ja
Zähler
Stromzähler
Stromzähler erfasst
Wärmemengenzähler
Informationen
Bemerkungen
Heizkurve: 25.5/21/0