Weiterhin alles Gute Michael Schumacher!
| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 2903 | Luft/Wasser | Wolf CHA 10 | 10.0 | 2026 | 190 | 3 | 2187.0 | 8075.0 | 3.69 | 1367.0 | 4557.0 | 3.33 | 820.0 | 3518.0 | 4.29 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 2903 | Luft/Wasser | Wolf CHA 10 | 10.0 | 2025 | 190 | 3 | 5947.0 | 25374.0 | 2038 | 4.27 | 1137.0 | 4083.0 | 737 | 3.59 | 920.0 | 3554.0 | 677 | 3.86 | 659.0 | 3105.0 | 624 | 4.71 | 401.0 | 2150.0 | 5.36 | 164.0 | 904.0 | 5.51 | 37.0 | 201.0 | 5.43 | 52.0 | 249.0 | 4.79 | 48.0 | 250.0 | 5.21 | 156.0 | 904.0 | 5.79 | 517.0 | 2788.0 | 5.39 | 795.0 | 3195.0 | 4.02 | 1061.0 | 3991.0 | 3.76 | |||||||||||||||||||||
| 2903 | Luft/Wasser | Wolf CHA 10 | 10.0 | 2024 | 190 | 3 | 7353.0 | 24031.0 | 3.27 | 1730.0 | 3847.0 | 2.22 | 1014.0 | 2750.0 | 2.71 | 1019.0 | 2697.0 | 2.65 | 885.0 | 2063.0 | 2.33 | 98.0 | 505.0 | 5.15 | 92.0 | 554.0 | 6.02 | 53.0 | 289.0 | 5.45 | 55.0 | 311.0 | 5.65 | 223.0 | 1331.0 | 5.97 | 390.0 | 2433.0 | 6.24 | 753.0 | 3368.0 | 4.47 | 1041.0 | 3883.0 | 3.73 | |||||||||||||||||||||||||
| 2903 | Luft/Wasser | Wolf CHA 10 | 10.0 | 2023 | 190 | 3 | 6316.0 | 24477.0 | 3.88 | 1033.0 | 4241.0 | 4.11 | 1139.0 | 4606.0 | 4.04 | 545.0 | 2698.0 | 4.95 | 604.0 | 3051.0 | 5.05 | 171.0 | 900.0 | 5.26 | 47.0 | 190.0 | 4.04 | 58.0 | 225.0 | 3.88 | 54.0 | 178.0 | 3.30 | 58.0 | 197.0 | 3.40 | 281.0 | 1340.0 | 4.77 | 980.0 | 3194.0 | 3.26 | 1346.0 | 3657.0 | 2.72 | |||||||||||||||||||||||||
| 2903 | Luft/Wasser | Wolf CHA 10 | 10.0 | 2022 | 190 | 3 | 5253.0 | 23541.0 | 90 | 4.48 | 1071.0 | 4079.0 | 3.81 | 708.0 | 3172.0 | 4.48 | 627.0 | 3024.0 | 4.82 | 512.0 | 2558.0 | 5.00 | 140.0 | 799.0 | 5.71 | 56.0 | 307.0 | 5.48 | 63.0 | 360.0 | 35 | 5.71 | 56.0 | 295.0 | 29 | 5.27 | 59.0 | 263.0 | 26 | 4.46 | 189.0 | 1131.0 | 5.98 | 608.0 | 3172.0 | 5.22 | 1164.0 | 4381.0 | 3.76 | |||||||||||||||||||||
| 2903 | Luft/Wasser | Wolf CHA 10 | 10.0 | 2021 | 190 | 3 | 1059.0 | 4056.0 | 744 | 3.83 | 1059.0 | 4056.0 | 744 | 3.83 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 2903 | Luft/Wasser | Wolf CHA 10 | 10.0 | 190 |
| NR | 2903 |
| Username | platon |
| Einbaujahr der WP | 2021-10-22 |
| PLZ des Wohnortes | 78224 |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | Wolf CHA 10 |
| modulierend | Ja |
| Leistung (0/35) | 10.0 kW |
| berechneter Endenergiebedarf | 0.0 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 47 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | Radiatoren |
| elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
| elektr. Verbrauch HP gem./DB | 0 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | intern > erfasst: Kompressor,Steuerung,Pumpen |
| WMZ | intern |
| Mittlere Raumtemp. | 21.0 °C |
| Mittlere Wärmequellentemperatur | 0.0 °C |
| Heizung max. Vorlauf Temp. | 47.0 °C |
| Spreizung Heizkr. | 4.0 |
| Heizflaeche | 190 m² |
| Lüftung | Fenster |
| Personen | 3 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen | Aktuelles: Seit Mitte 2023 zeichnet sich ein schleichender Kompressor Defekt ab. 04/2024 reklamiert. Wurde dann am 02.05.2024 ausgetauscht (Garantie). Nur Heizkörper/Radiatoren! Diese sind meist auf Stand 1970, aber relativ groß. 1 Bad mit zusätzlicher Fußbodenheizung (normal am Vorlauf angeschlossen). Bungalow Bj 1970 mit ELW, 2021 letzte Geschossdecke sehr gut isoliert. 2021 Neue Fenster 2 fach. Mauerwerk original 30er HLZ. Ansonsten keine zusätzliche Wanddämmung. WP läuft im Winter durch. Meist einmal WW Bereitung pro Tag/400 l Speicher. Reihenspeicher 100 l mit zusätzlicher Heizkreispumpe im Stromverbrauch enthalten. Oft Zuheizung mit einem Kaminofen (ohne Wasseranbindung) für Hauptwohnraum. Meist nur 1 Verdichterstart pro Tag (nach WW Bereitung wird dieser immer automatisch neu gestartet). In Übergangszeit läuft die WP nur von 5:00 bis 10:00 mit anschließender WW Bereitung. Haus hat geschätzt 120-150 kWh/m²/anno. |