Weiterhin alles Gute Michael Schumacher!
| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 2954 | Luft/Wasser | Wolf CHA 7-400 300/50s | 5.0 | 2026 | 145 | 4 | 400.8 | 1935.0 | 584 | 4.83 | 400.8 | 1935.0 | 584 | 4.83 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 2954 | Luft/Wasser | Wolf CHA 7-400 300/50s | 5.0 | 2025 | 145 | 4 | 1983.3 | 10188.0 | 2661 | 5.14 | 294.0 | 1572.0 | 456 | 5.35 | 233.0 | 1262.0 | 325 | 5.42 | 209.0 | 1065.0 | 249 | 5.10 | 92.9 | 479.0 | 88 | 5.16 | 74.0 | 275.0 | 40 | 3.72 | 136.0 | 563.0 | 159 | 4.14 | 185.4 | 845.0 | 284 | 4.56 | 199.7 | 780.0 | 285 | 3.91 | 68.0 | 303.0 | 51 | 4.46 | 88.0 | 451.0 | 90 | 5.13 | 196.7 | 1251.0 | 315 | 6.36 | 206.6 | 1342.0 | 319 | 6.50 | ||||||||||||
| 2954 | Luft/Wasser | Wolf CHA 7-400 300/50s | 5.0 | 2024 | 145 | 4 | 2042.9 | 11249.0 | 3105 | 5.51 | 284.0 | 1724.0 | 532 | 6.07 | 188.1 | 1292.0 | 348 | 6.87 | 173.0 | 1147.0 | 275 | 6.63 | 138.0 | 831.0 | 189 | 6.02 | 134.0 | 565.0 | 153 | 4.22 | 150.9 | 608.0 | 190 | 4.03 | 201.0 | 854.0 | 294 | 4.25 | 196.0 | 820.0 | 294 | 4.18 | 112.0 | 506.0 | 139 | 4.52 | 83.9 | 465.0 | 89 | 5.54 | 174.0 | 1085.0 | 285 | 6.24 | 208.0 | 1352.0 | 317 | 6.50 | ||||||||||||
| 2954 | Luft/Wasser | Wolf CHA 7-400 300/50s | 5.0 | 2023 | 145 | 4 | 2111.9 | 11818.0 | 3200 | 5.60 | 282.0 | 1777.0 | 525 | 6.30 | 237.0 | 1466.0 | 433 | 6.19 | 195.0 | 1189.0 | 283 | 6.10 | 166.2 | 934.0 | 200 | 5.62 | 116.7 | 501.0 | 67 | 4.29 | 180.0 | 819.0 | 229 | 4.55 | 168.0 | 655.0 | 209 | 3.90 | 131.0 | 650.0 | 196 | 4.96 | 105.0 | 492.0 | 128 | 4.69 | 96.0 | 576.0 | 117 | 6.00 | 182.0 | 1222.0 | 353 | 6.71 | 253.0 | 1537.0 | 460 | 6.08 | ||||||||||||
| 2954 | Luft/Wasser | Wolf CHA 7-400 300/50s | 5.0 | 2022 | 145 | 4 | 1046.3 | 5563.0 | 1267 | 5.32 | 24.0 | 116.0 | 4.83 | 75.0 | 343.0 | 66 | 4.57 | 82.0 | 443.0 | 78 | 5.40 | 66.0 | 305.0 | 49 | 4.62 | 50.0 | 195.0 | 30 | 3.90 | 78.0 | 356.0 | 73 | 4.56 | 103.0 | 536.0 | 115 | 5.20 | 212.7 | 1360.0 | 356 | 6.39 | 355.6 | 1909.0 | 500 | 5.37 |
| NR | 2954 |
| Username | svensemann |
| Einbaujahr der WP | 2022-01-16 |
| PLZ des Wohnortes | 24229 |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | Wolf CHA 7-400 300/50s |
| modulierend | Ja |
| Leistung (0/35) | 5.0 kW |
| berechneter Primärenergiebedarf | 13.0 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 45 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | FBH |
| elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
| elektr. Verbrauch HP gem./DB | 0 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | extern > erfasst: Kompressor,Steuerung,Pumpen |
| WMZ | intern |
| Mittlere Raumtemp. | 20.0 °C |
| Mittlere Wärmequellentemperatur | 0.0 °C |
| Heizung max. Vorlauf Temp. | 20.0 °C |
| Spreizung Heizkr. | 3.0 |
| Heizflaeche | 145 m² |
| Lüftung | zenKWLWR |
| Personen | 4 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen | Neubau (2022) gemäß KFW-40+ Standard. Heizkurve: 26°C VL bei 8°C Außentemperatur - 29°C VL bei -9°C Außentemperatur (Normaußentemperatur). Sommer-Winter-Umschaltung: 15°C. Heizen bei unter 10°C außen von 8:00 - 17:00, bei unter 3°C außerhalb dieser Zeit zusätzlich im Absenkbetrieb. Bei genügend PV-Überschuss: WW = 58°C. |