Weiterhin alles Gute Michael Schumacher!
| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 3098 | Sole/Wasser | NIBE S1255-6PC | 6.0 | 2025 | 141 | 4 | 1062.8 | 5227.4 | 2293 | 4.92 | 269.8 | 1586.7 | 715 | 5.88 | 250.2 | 1416.0 | 632 | 5.66 | 203.0 | 1076.0 | 538 | 5.30 | 99.0 | 467.0 | 211 | 4.72 | 61.8 | 198.0 | 60 | 3.20 | 44.0 | 119.7 | 34 | 2.72 | 45.0 | 123.5 | 35 | 2.74 | 44.0 | 110.5 | 32 | 2.51 | 46.0 | 130.0 | 36 | 2.83 | ||||||||||||||||||||||||
| 3098 | Sole/Wasser | NIBE S1255-6PC | 6.0 | 2024 | 141 | 4 | 1347.5 | 7637.2 | 3595 | 5.67 | 246.9 | 1491.8 | 699 | 6.04 | 171.5 | 1017.4 | 549 | 5.93 | 131.3 | 914.3 | 496 | 6.96 | 106.6 | 564.5 | 275 | 5.30 | 54.3 | 136.9 | 49 | 2.52 | 48.9 | 206.3 | 35 | 4.22 | 43.3 | 86.9 | 24 | 2.01 | 45.6 | 95.2 | 28 | 2.09 | 43.7 | 106.6 | 29 | 2.44 | 74.7 | 441.3 | 172 | 5.91 | 163.5 | 1178.1 | 563 | 7.21 | 217.2 | 1397.9 | 676 | 6.44 | ||||||||||||
| 3098 | Sole/Wasser | NIBE S1255-6PC | 6.0 | 2023 | 141 | 4 | 1396.8 | 7336.3 | 2393 | 5.25 | 218.1 | 1315.8 | 6.03 | 214.4 | 1233.2 | 5.75 | 194.3 | 1064.5 | 561 | 5.48 | 137.6 | 752.0 | 395 | 5.47 | 56.8 | 143.7 | 64 | 2.53 | 51.4 | 98.6 | 45 | 1.92 | 45.5 | 85.1 | 39 | 1.87 | 45.8 | 91.3 | 35 | 1.99 | 42.7 | 84.0 | 33 | 1.97 | 61.6 | 309.8 | 133 | 5.03 | 139.5 | 961.3 | 464 | 6.89 | 189.1 | 1197.0 | 624 | 6.33 | ||||||||||||||
| 3098 | Sole/Wasser | NIBE S1255-6PC | 6.0 | 2022 | 141 | 4 | 1402.9 | 7242.2 | 5.16 | 230.9 | 1327.0 | 5.75 | 183.0 | 1081.5 | 5.91 | 197.0 | 1142.6 | 5.80 | 118.0 | 642.0 | 5.44 | 56.7 | 183.3 | 3.23 | 50.3 | 108.9 | 2.17 | 48.0 | 81.8 | 1.70 | 54.0 | 82.3 | 1.52 | 43.8 | 98.8 | 2.26 | 43.0 | 98.0 | 2.28 | 136.0 | 943.0 | 6.93 | 242.2 | 1453.0 | 6.00 |
| NR | 3098 |
| Username | traehus20 |
| Einbaujahr der WP | 2021-08-26 |
| PLZ des Wohnortes | 39171 |
| Bauart | Sole/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | NIBE S1255-6PC |
| modulierend | Ja |
| Leistung (0/35) | 6.0 kW |
| berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 45 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Grabenkollektor |
| Tiefe | 2.0 m |
| Fläche | 0 m² |
| Heizungsart | FBH |
| elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
| elektr. Verbrauch HP gem./DB | 0 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung,Pumpen |
| WMZ | intern |
| Mittlere Raumtemp. | 22.0 °C |
| Mittlere Wärmequellentemperatur | 0.0 °C |
| Heizung max. Vorlauf Temp. | 32.0 °C |
| Spreizung Heizkr. | 0.0 |
| Heizflaeche | 141 m² |
| Lüftung | zenKWLWR |
| Personen | 4 |
| Grabenkollektor Helfer | Ja |
| Grabenkollektor Erfahrung | 1xEigenleistung |
| Bemerkungen | Kühlung läuft im Sommer mit, rechne ich aber nicht mit ein. WP ist auf 40Hz begrenzt. Die schlechten AZ im Sommer liegen am hohen Standbyverbrauch (ca. 20kWh/Monat) der Nibe den ich aber nicht abziehe. Durch PV ist in der Übergangszeit der Verdichter Nachts gesperrt womit wir etwas Effizienz einbüßen. |