Weiterhin alles Gute Michael Schumacher!
| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 3128 | Luft/Wasser | Wolf CHA-10 | 10.0 | 2025 | 209 | 5 | 3245.0 | 13802.0 | 2925 | 4.25 | 700.0 | 2786.0 | 616 | 3.98 | 564.0 | 2306.0 | 518 | 4.09 | 380.0 | 1789.0 | 387 | 4.71 | 133.0 | 660.0 | 120 | 4.96 | 71.0 | 305.0 | 44 | 4.30 | 43.0 | 135.0 | 15 | 3.14 | 47.0 | 187.0 | 20 | 3.98 | 41.0 | 155.0 | 17 | 3.78 | 50.0 | 182.0 | 22 | 3.64 | 187.0 | 988.0 | 189 | 5.28 | 429.0 | 1852.0 | 421 | 4.32 | 600.0 | 2457.0 | 556 | 4.10 | ||||||||||||
| 3128 | Luft/Wasser | Wolf CHA-10 | 10.0 | 2024 | 209 | 5 | 3221.0 | 14385.0 | 3119 | 4.47 | 738.0 | 2941.0 | 627 | 3.99 | 402.0 | 2057.0 | 480 | 5.12 | 374.0 | 1876.0 | 441 | 5.02 | 256.0 | 1215.0 | 280 | 4.75 | 32.0 | 121.0 | 14 | 3.78 | 49.0 | 199.0 | 21 | 4.06 | 45.0 | 189.0 | 21 | 4.20 | 28.0 | 118.0 | 13 | 4.21 | 63.0 | 259.0 | 35 | 4.11 | 129.0 | 684.0 | 122 | 5.30 | 421.0 | 1981.0 | 463 | 4.71 | 684.0 | 2745.0 | 602 | 4.01 | ||||||||||||
| 3128 | Luft/Wasser | Wolf CHA-10 | 10.0 | 2023 | 209 | 5 | 3177.0 | 14414.0 | 3129 | 4.54 | 589.0 | 2467.0 | 554 | 4.19 | 536.0 | 2302.0 | 515 | 4.29 | 439.0 | 2118.0 | 483 | 4.82 | 284.0 | 1441.0 | 310 | 5.07 | 69.0 | 300.0 | 43 | 4.35 | 40.0 | 165.0 | 17 | 4.13 | 52.0 | 203.0 | 22 | 3.90 | 33.0 | 126.0 | 14 | 3.82 | 51.0 | 196.0 | 20 | 3.84 | 134.0 | 640.0 | 118 | 4.78 | 370.0 | 1773.0 | 408 | 4.79 | 580.0 | 2683.0 | 625 | 4.63 | ||||||||||||
| 3128 | Luft/Wasser | Wolf CHA-10 | 10.0 | 2022 | 209 | 5 | 3191.0 | 13365.0 | 2767 | 4.19 | 762.0 | 2828.0 | 599 | 3.71 | 444.0 | 2026.0 | 473 | 4.56 | 369.0 | 1702.0 | 383 | 4.61 | 284.0 | 1325.0 | 290 | 4.67 | 76.0 | 308.0 | 38 | 4.05 | 36.0 | 119.0 | 13 | 3.31 | 57.0 | 233.0 | 25 | 4.09 | 38.0 | 135.0 | 15 | 3.55 | 62.0 | 237.0 | 29 | 3.82 | 79.0 | 387.0 | 57 | 4.90 | 315.0 | 1541.0 | 317 | 4.89 | 669.0 | 2524.0 | 528 | 3.77 |
| NR | 3128 |
| Username | JacobP |
| Einbaujahr der WP | 2021-12-23 |
| PLZ des Wohnortes | 71665 |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | Wolf CHA-10 |
| modulierend | Ja |
| Leistung (0/35) | 10.0 kW |
| berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 46 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | Radiatoren |
| elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
| elektr. Verbrauch HP gem./DB | 0 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung,Pumpen |
| WMZ | intern |
| Mittlere Raumtemp. | 20.0 °C |
| Mittlere Wärmequellentemperatur | 0.0 °C |
| Heizung max. Vorlauf Temp. | 46.0 °C |
| Spreizung Heizkr. | 5.0 |
| Heizflaeche | 209 m² |
| Lüftung | Fenster |
| Personen | 5 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen | Doppelhaushälfte Bj. 1992; bis Ende 2021 mit Gas beheizt (Verbrauch in Vorjahren zw. 15.500 und 21.500 kWh p.a. - Median 17.500 kWh p.a.) |