Weiterhin alles Gute Michael Schumacher!
| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 3201 | Sole/Wasser | Viessmann 200-G BWC 201.B17 | 17.0 | 2025 | 260 | 4 | 5657.0 | 19893.0 | 3.52 | 1711.0 | 5531.0 | 3.23 | 1310.0 | 4831.0 | 3.69 | 982.0 | 3562.0 | 3.63 | 640.0 | 2351.0 | 3.67 | 388.0 | 1500.0 | 3.87 | 157.0 | 558.0 | 3.55 | 101.0 | 370.0 | 3.66 | 137.0 | 430.0 | 3.14 | 231.0 | 760.0 | 3.29 | ||||||||||||||||||||||||||||||||||
| 3201 | Sole/Wasser | Viessmann 200-G BWC 201.B17 | 17.0 | 2024 | 260 | 4 | 9043.0 | 33513.0 | 3.71 | 1687.0 | 5499.0 | 3.26 | 1105.0 | 4563.0 | 4.13 | 951.0 | 3608.0 | 3.79 | 727.0 | 2751.0 | 3.78 | 330.0 | 1252.0 | 3.79 | 248.0 | 953.0 | 3.84 | 82.0 | 330.0 | 4.02 | 146.0 | 532.0 | 3.64 | 301.0 | 1188.0 | 3.95 | 656.0 | 2605.0 | 3.97 | 1435.0 | 5335.0 | 3.72 | 1375.0 | 4897.0 | 3.56 | |||||||||||||||||||||||||
| 3201 | Sole/Wasser | Viessmann 200-G BWC 201.B17 | 17.0 | 2023 | 260 | 4 | 4636.0 | 17313.0 | 3.73 | 905.0 | 3310.0 | 3.66 | 283.0 | 1136.0 | 4.01 | 93.0 | 333.0 | 3.58 | 81.0 | 297.0 | 3.67 | 115.0 | 421.0 | 3.66 | 109.0 | 409.0 | 3.75 | 526.0 | 1893.0 | 3.60 | 1147.0 | 4403.0 | 3.84 | 1377.0 | 5111.0 | 3.71 |
| NR | 3201 |
| Username | SnakeWP |
| Einbaujahr der WP | 2022-11-08 |
| PLZ des Wohnortes | 46240 |
| Bauart | Sole/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | Viessmann 200-G BWC 201.B17 |
| modulierend | Nein |
| Leistung (0/35) | 17.0 kW |
| berechneter Primärenergiebedarf | 118.0 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 50 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | x Erdbohrungen a |
| Tiefe | 100.0 m |
| Fläche | 0 m² |
| Heizungsart | FBH |
| elektr. Verbrauch WP ohne NA gem./DB | 3800 Watt DB |
| elektr. Verbrauch HP gem./DB | 100 Watt |
| elektr. Verbrauch WQ P gem./DB | 140 Watt |
| Stromzähler | extern > erfasst: Kompressor,Steuerung,Pumpen |
| WMZ | intern |
| Mittlere Raumtemp. | 22.0 °C |
| Mittlere Wärmequellentemperatur | 6.0 °C |
| Heizung max. Vorlauf Temp. | 48.0 °C |
| Spreizung Heizkr. | 9.0 |
| Heizflaeche | 260 m² |
| Lüftung | Fenster |
| Personen | 6 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen | 3 Erdbohrungen a 100m FBH und Heizkörper |