Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
323 | Luft/Wasser | Zubadan PUHZ-HRP 100 YHA | 11.2 | 2019 | 189 | 2 | 1609.0 | 6677.0 | 4.15 | 481.2 | 1828.0 | 3.80 | 265.5 | 1057.0 | 3.98 | 224.6 | 1058.0 | 4.71 | 82.9 | 336.0 | 4.05 | 57.8 | 256.0 | 4.43 | 0.1 | 0.5 | 5.00 | 0.1 | 0.5 | 5.00 | 0.1 | 0.5 | 5.00 | 0.1 | 0.5 | 5.00 | 122.3 | 573.0 | 4.69 | 374.3 | 1567.0 | 4.19 | ||||||||||||||||||||||||||||
323 | Luft/Wasser | Zubadan PUHZ-HRP 100 YHA | 11.2 | 2018 | 189 | 2 | 2205.4 | 8706.0 | 3.95 | 423.8 | 1745.0 | 4.12 | 587.0 | 2021.0 | 3.44 | 400.3 | 1526.0 | 3.81 | 45.9 | 196.0 | 4.27 | 19.0 | 89.0 | 4.68 | 0.1 | 0.5 | 5.00 | 0.1 | 0.5 | 5.00 | 0.1 | 0.5 | 5.00 | 0.1 | 0.5 | 5.00 | 93.0 | 424.0 | 4.56 | 319.1 | 1340.0 | 4.20 | 316.9 | 1363.0 | 4.30 | |||||||||||||||||||||||||
323 | Luft/Wasser | Zubadan PUHZ-HRP 100 YHA | 11.2 | 2017 | 189 | 2 | 2857.7 | 11769.3 | 4.12 | 668.1 | 2707.0 | 4.05 | 459.8 | 1847.0 | 4.02 | 257.9 | 1113.0 | 4.32 | 254.4 | 1013.0 | 3.98 | 92.8 | 343.0 | 3.70 | 36.2 | 83.0 | 2.29 | 35.4 | 73.0 | 2.06 | 0.1 | 0.3 | 3.00 | 17.7 | 101.0 | 5.71 | 125.4 | 675.0 | 5.38 | 405.5 | 1789.0 | 4.41 | 504.4 | 2025.0 | 4.01 | |||||||||||||||||||||||||
323 | Luft/Wasser | Zubadan PUHZ-HRP 100 YHA | 11.2 | 2016 | 189 | 2 | 3206.9 | 12067.0 | 3.76 | 572.0 | 2079.0 | 3.63 | 459.8 | 1720.0 | 3.74 | 421.2 | 1600.0 | 3.80 | 232.0 | 897.0 | 3.87 | 78.7 | 246.0 | 3.13 | 34.9 | 68.0 | 1.95 | 42.0 | 108.0 | 2.57 | 39.1 | 88.0 | 2.25 | 41.1 | 101.0 | 2.46 | 245.2 | 1116.0 | 4.55 | 505.2 | 1975.0 | 3.91 | 535.7 | 2069.0 | 3.86 | |||||||||||||||||||||||||
323 | Luft/Wasser | Zubadan PUHZ-HRP 100 YHA | 11.2 | 2015 | 189 | 2 | 2880.9 | 11275.0 | 3.91 | 647.0 | 2410.0 | 3.72 | 489.9 | 1793.0 | 3.66 | 381.0 | 1509.0 | 3.96 | 223.0 | 860.0 | 3.86 | 130.3 | 504.0 | 3.87 | 45.7 | 134.0 | 2.93 | 37.0 | 62.0 | 1.68 | 49.0 | 129.0 | 2.63 | 90.0 | 336.0 | 3.73 | 228.0 | 1027.0 | 4.50 | 275.0 | 1204.0 | 4.38 | 285.0 | 1307.0 | 4.59 | |||||||||||||||||||||||||
323 | Luft/Wasser | Zubadan PUHZ-HRP 100 YHA | 11.2 | 2014 | 189 | 2 | 3161.7 | 11251.6 | 3.56 | 669.7 | 2360.0 | 3.52 | 478.3 | 1781.0 | 3.72 | 409.3 | 998.0 | 2.44 | 155.4 | 441.0 | 2.84 | 113.1 | 400.0 | 3.54 | 35.6 | 82.0 | 2.30 | 43.9 | 102.0 | 2.32 | 66.9 | 199.0 | 2.97 | 61.1 | 207.0 | 3.39 | 138.5 | 667.0 | 4.82 | 353.9 | 1652.6 | 4.67 | 636.0 | 2362.0 | 3.71 | |||||||||||||||||||||||||
323 | Luft/Wasser | Zubadan PUHZ-HRP 100 YHA | 11.2 | 2013 | 189 | 2 | 5551.7 | 18676.0 | 3.36 | 1046.8 | 3366.0 | 3.22 | 896.6 | 2983.0 | 3.33 | 918.1 | 2962.0 | 3.23 | 378.9 | 1379.0 | 3.64 | 235.8 | 1002.0 | 4.25 | 231.7 | 517.0 | 2.23 | 119.1 | 192.0 | 1.61 | 47.3 | 151.0 | 3.19 | 123.7 | 692.0 | 5.59 | 268.0 | 1054.0 | 3.93 | 595.7 | 2045.0 | 3.43 | 690.0 | 2333.0 | 3.38 | |||||||||||||||||||||||||
323 | Luft/Wasser | Zubadan PUHZ-HRP 100 YHA | 11.2 | 2012 | 189 | 2 | 4849.2 | 17033.0 | 3.51 | 847.9 | 2986.0 | 3.52 | 1062.5 | 3224.0 | 3.03 | 403.9 | 1605.0 | 3.97 | 319.8 | 1248.0 | 3.90 | 183.4 | 662.0 | 3.61 | 107.3 | 292.0 | 2.72 | 58.9 | 107.0 | 1.82 | 54.6 | 127.0 | 2.33 | 142.9 | 581.0 | 4.07 | 343.2 | 1363.0 | 3.97 | 553.9 | 2069.0 | 3.74 | 770.9 | 2769.0 | 3.59 | |||||||||||||||||||||||||
323 | Luft/Wasser | Zubadan PUHZ-HRP 100 YHA | 11.2 | 2011 | 189 | 2 | 3708.8 | 15875.2 | 4.28 | 641.2 | 3127.8 | 4.88 | 455.5 | 2475.0 | 5.43 | 425.9 | 2216.7 | 5.20 | 181.8 | 725.7 | 3.99 | 46.0 | 115.0 | 2.50 | 47.3 | 122.0 | 2.58 | 106.3 | 341.0 | 3.21 | 52.0 | 137.0 | 2.63 | 159.9 | 569.0 | 3.56 | 329.4 | 1297.0 | 3.94 | 629.1 | 2286.0 | 3.63 | 634.4 | 2463.0 | 3.88 | |||||||||||||||||||||||||
323 | Luft/Wasser | Zubadan PUHZ-HRP 100 YHA | 11.2 | 2010 | 189 | 2 | 6571.7 | 20379.5 | 3.10 | 1338.6 | 3138.3 | 2.34 | 1001.2 | 3079.4 | 3.08 | 626.2 | 2179.2 | 3.48 | 343.1 | 1243.8 | 3.63 | 325.3 | 1207.2 | 3.71 | 86.2 | 235.0 | 2.73 | 54.8 | 138.3 | 2.52 | 102.4 | 133.7 | 1.31 | 219.4 | 703.3 | 3.21 | 420.4 | 1463.0 | 3.48 | 718.3 | 2497.2 | 3.48 | 1335.8 | 4361.1 | 3.26 | |||||||||||||||||||||||||
323 | Luft/Wasser | Zubadan PUHZ-HRP 100 YHA | 11.2 | 2009 | 189 | 2 | 2290.5 | 6708.4 | 2.93 | 264.0 | 299.0 | 1.13 | 107.1 | 248.0 | 2.32 | 419.2 | 1383.6 | 3.30 | 429.9 | 1639.4 | 3.81 | 1070.3 | 3138.4 | 2.93 |
NR | 323 |
Username | Zwerius |
Einbaujahr | 2009-06-18 |
PLZ des Wohnortes | NL- |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Zubadan PUHZ-HRP 100 YHA |
Leistung (0/35) | 11.2 kW |
berechneter Primärenergiebedarf | 64.1 kWh/m²/anno |
WW über WP | Nein |
WW Temperatur | 52 °C |
WW Legionellenschaltung | Ja |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH und Radiatoren |
elektr. Verbrauch WP ohne NA gem./DB | 3100 Watt DB |
elektr. Verbrauch HP gem./DB | 155 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Mittlere Raumtemp. | 22 °C |
Mittlere Wärmequellentemperatur | 5.0 °C |
Heizung max. Vorlauf Temp. | 32.0 °C |
Spreizung Heizkr. | 5.0 |
Heizflaeche | 189 m² |
Lüftung | zenKWLWR |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Brauchwasserspeicher 100 liter, wird zwei mal am Tag während eine Stunde freigegeben für Aufheizung. Brauchwasser wird während Sommermonaten mit nur 50% Leistung des Aussengeräts aufgeheizt (wegen höheren AZ bei Teillast). Vorlauftemperatur der Heizung ist 25-32°C (Aussentemperaturgeregelt über PAC-IF021B-E), also ohne Mischventile. Das wasser vom WP geht direkt in die FBH. Wir haben kein Speicher und kein Kaminofen. Seit 15-02-2011 ist am Zubadan das Startpunkt der Flash-Injektion auf -3°C eingestellt (ab Werk ist +3°C eingestellt) um damit die AZ (bei Aussentemperaturen rund 0°C) weiter zu verbessern. Die guten Ergebnisse von Anfang 2011 wurden leider verursacht durch ein fehlerhaften kWh-Messung! Seit März 2014 ist ein PUHZ-SHW112YHA eingebaut. Wegen kaputte Verdampfer der erste Maschine (Garantie). Seit August 2017 haben wir eine separate Warm Wasser Wärmepumpe für Brauchwasser. Die daten sind seit dem also nur für Heizung. e-mail:z.kriegsman@gmail.com |