Weiterhin alles Gute Michael Schumacher!
| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 3333 | Luft/Wasser | Vaillant aroTherm 1056 | 9.2 | 2025 | 145 | 2 | 3898.0 | 13158.0 | 2378 | 3.38 | 874.0 | 2882.0 | 482 | 3.30 | 790.0 | 2413.0 | 438 | 3.05 | 557.0 | 2012.0 | 316 | 3.61 | 281.0 | 1115.0 | 177 | 3.97 | 174.0 | 633.0 | 100 | 3.64 | 91.0 | 286.0 | 39 | 3.14 | 63.0 | 163.0 | 19 | 2.59 | 75.0 | 213.0 | 92 | 2.84 | 125.0 | 422.0 | 185 | 3.38 | 298.0 | 1210.0 | 196 | 4.06 | 570.0 | 1809.0 | 334 | 3.17 | ||||||||||||||||
| 3333 | Luft/Wasser | Vaillant aroTherm 1056 | 9.2 | 2024 | 145 | 2 | 4326.0 | 15682.0 | 2691 | 3.63 | 899.0 | 2962.0 | 474 | 3.29 | 557.0 | 2097.0 | 306 | 3.76 | 525.0 | 2013.0 | 294 | 3.83 | 338.0 | 1364.0 | 220 | 4.04 | 98.0 | 331.0 | 45 | 3.38 | 83.0 | 264.0 | 40 | 3.18 | 57.0 | 153.0 | 19 | 2.68 | 49.0 | 111.0 | 13 | 2.27 | 138.0 | 494.0 | 74 | 3.58 | 308.0 | 1258.0 | 443 | 4.08 | 562.0 | 2080.0 | 343 | 3.70 | 712.0 | 2555.0 | 420 | 3.59 | ||||||||||||
| 3333 | Luft/Wasser | Vaillant aroTherm 1056 | 9.2 | 2023 | 145 | 2 | 1671.0 | 5904.0 | 906 | 3.53 | 53.0 | 102.0 | 8 | 1.92 | 46.0 | 113.0 | 13 | 2.46 | 57.0 | 153.0 | 18 | 2.68 | 259.0 | 1060.0 | 165 | 4.09 | 540.0 | 1968.0 | 310 | 3.64 | 716.0 | 2508.0 | 392 | 3.50 |
| NR | 3333 |
| Username | WP-Leeste |
| Einbaujahr der WP | 2023-06-08 |
| PLZ des Wohnortes | 28844 |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | Vaillant aroTherm 1056 |
| modulierend | Ja |
| Leistung (0/35) | 9.2 kW |
| berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 50 °C |
| WW Legionellenschaltung | wöchentlich |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | Radiatoren |
| elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
| elektr. Verbrauch HP gem./DB | 0 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | intern > erfasst: Kompressor,Steuerung,Pumpen |
| WMZ | intern |
| Mittlere Raumtemp. | 0.0 °C |
| Mittlere Wärmequellentemperatur | 0.0 °C |
| Heizung max. Vorlauf Temp. | 50.0 °C |
| Spreizung Heizkr. | 0.0 |
| Heizflaeche | 145 m² |
| Lüftung | Fenster |
| Personen | 2 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen |