Weiterhin alles Gute Michael Schumacher!
| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 3347 | Luft/Wasser | IDM AERO SLM 3-11 HGL | 5.9 | 2025 | 160 | 4 | 4529.0 | 14386.0 | 2206 | 3.18 | 1397.0 | 4178.0 | 689 | 2.99 | 1238.0 | 3678.0 | 583 | 2.97 | 890.0 | 2941.0 | 478 | 3.30 | 386.0 | 1398.0 | 187 | 3.62 | 421.0 | 1553.0 | 209 | 3.69 | 106.0 | 330.0 | 30 | 3.11 | 91.0 | 308.0 | 30 | 3.38 | ||||||||||||||||||||||||||||||||
| 3347 | Luft/Wasser | IDM AERO SLM 3-11 HGL | 5.9 | 2024 | 160 | 3 | 6131.0 | 19962.0 | 3114 | 3.26 | 1323.0 | 3820.0 | 632 | 2.89 | 654.0 | 2324.0 | 362 | 3.55 | 653.0 | 2199.0 | 305 | 3.37 | 498.0 | 1594.0 | 219 | 3.20 | 154.0 | 504.0 | 52 | 3.27 | 126.0 | 427.0 | 42 | 3.39 | 90.0 | 310.0 | 28 | 3.44 | 75.0 | 259.0 | 22 | 3.45 | 201.0 | 747.0 | 101 | 3.72 | 347.0 | 1426.0 | 187 | 4.11 | 795.0 | 2721.0 | 490 | 3.42 | 1215.0 | 3631.0 | 674 | 2.99 | ||||||||||||
| 3347 | Luft/Wasser | IDM AERO SLM 3-11 HGL | 5.9 | 2023 | 160 | 3 | 2387.6 | 8567.0 | 1297 | 3.59 | 28.0 | 85.0 | 9 | 3.04 | 86.0 | 284.0 | 26 | 3.30 | 99.3 | 344.0 | 34 | 3.46 | 99.3 | 325.0 | 36 | 3.27 | 304.0 | 1197.0 | 157 | 3.94 | 748.0 | 2817.0 | 480 | 3.77 | 1023.0 | 3515.0 | 555 | 3.44 |
| NR | 3347 |
| Username | sba |
| Einbaujahr der WP | 2023-06-22 |
| PLZ des Wohnortes | 83278 |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Bi |
| Hersteller Typ | IDM AERO SLM 3-11 HGL |
| modulierend | Ja |
| Leistung (0/35) | 5.9 kW |
| berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 42 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | Radiatoren |
| elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
| elektr. Verbrauch HP gem./DB | 0 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | intern > erfasst: Kompressor |
| WMZ | intern |
| Mittlere Raumtemp. | 20.5 °C |
| Mittlere Wärmequellentemperatur | 0.0 °C |
| Heizung max. Vorlauf Temp. | 49.0 °C |
| Spreizung Heizkr. | 0.0 |
| Heizflaeche | 160 m² |
| Lüftung | Fenster |
| Personen | 4 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen | Haus BJ 2000 230qm, Radiatoren, 21kWp PV Ost/West |