| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 3389 | Luft/Wasser | Daikin Ech2O 3HHT | 14.0 | 2025 | 140 | 3 | 3133.0 | 11099.0 | 3.54 | 906.0 | 3160.0 | 3.49 | 694.0 | 2294.0 | 3.31 | 528.0 | 1881.0 | 3.56 | 300.0 | 1098.0 | 3.66 | 77.0 | 257.0 | 3.34 | 54.0 | 179.0 | 3.31 | 45.0 | 139.0 | 3.09 | 47.0 | 149.0 | 3.17 | 100.0 | 369.0 | 3.69 | 382.0 | 1573.0 | 4.12 | |||||||||||||||||||||||||||||||
| 3389 | Luft/Wasser | Daikin Ech2O 3HHT | 14.0 | 2024 | 140 | 3 | 4028.0 | 14006.0 | 3.48 | 802.0 | 2604.0 | 3.25 | 534.0 | 1876.0 | 3.51 | 400.0 | 1834.0 | 4.59 | 266.0 | 1143.0 | 4.30 | 129.0 | 315.0 | 2.44 | 69.0 | 173.0 | 2.51 | 44.0 | 137.0 | 3.11 | 38.0 | 126.0 | 3.32 | 53.0 | 182.0 | 3.43 | 336.0 | 1245.0 | 3.71 | 593.0 | 1836.0 | 3.10 | 764.0 | 2535.0 | 3.32 | |||||||||||||||||||||||||
| 3389 | Luft/Wasser | Daikin Ech2O 3HHT | 14.0 | 2023 | 140 | 3 | 1802.0 | 5875.0 | 3.26 | 265.0 | 315.0 | 1.19 | 68.0 | 199.0 | 2.93 | 41.0 | 137.0 | 3.34 | 48.0 | 161.0 | 3.35 | 69.0 | 255.0 | 3.70 | 217.0 | 858.0 | 3.95 | 470.0 | 1708.0 | 3.63 | 624.0 | 2242.0 | 3.59 |
| NR | 3389 |
| Username | oxenator |
| Einbaujahr der WP | 2023-05-15 |
| PLZ des Wohnortes | 45770 |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | Daikin Ech2O 3HHT |
| modulierend | Ja |
| Leistung (0/35) | 14.0 kW |
| berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 47 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | FBH und Radiatoren |
| elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
| elektr. Verbrauch HP gem./DB | 0 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | intern > erfasst: Kompressor,Steuerung,Pumpen |
| WMZ | intern |
| Mittlere Raumtemp. | 22.0 °C |
| Mittlere Wärmequellentemperatur | 28.0 °C |
| Heizung max. Vorlauf Temp. | 54.0 °C |
| Spreizung Heizkr. | 0.0 |
| Heizflaeche | 140 m² |
| Lüftung | Fenster |
| Personen | 3 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen |