| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 3399 | Luft/Wasser | Alpha-Innotec LW81A | 8.4 | 2023 | 200 | 2 | 2837.0 | 9096.0 | 1998 | 3.22 | 678.0 | 1931.0 | 258 | 2.85 | 521.0 | 1689.0 | 1123 | 3.24 | 374.0 | 1253.0 | 142 | 3.35 | 223.0 | 970.0 | 85 | 4.35 | 23.0 | 192.0 | 7 | 8.35 | 11.0 | 3.0 | 1 | 0.27 | 8.0 | 0 | 2 | 0 | 0 | 0 | 8.0 | 0 | 2 | 4.0 | 8.0 | 1 | 2.00 | 476.0 | 1430.0 | 182 | 3.00 | 511.0 | 1620.0 | 195 | 3.17 | |||||||||||||||
| 3399 | Luft/Wasser | Alpha-Innotec LW81A | 8.4 | 2022 | 200 | 2 | 2705.0 | 8875.0 | 1028 | 3.29 | 747.0 | 2112.0 | 288 | 2.83 | 492.0 | 1568.0 | 189 | 3.19 | 299.0 | 1220.0 | 112 | 4.08 | 196.0 | 896.0 | 73 | 4.57 | 8.0 | 177.0 | 0 | 22.13 | 5.0 | 21.0 | 0 | 4.20 | 4.0 | 0 | 4 | 4.0 | 0 | 0 | 15.0 | 57.0 | 5 | 3.80 | 39.0 | 170.0 | 10 | 4.36 | 228.0 | 767.0 | 89 | 3.36 | 668.0 | 1887.0 | 258 | 2.82 | ||||||||||||||
| 3399 | Luft/Wasser | Alpha-Innotec LW81A | 8.4 | 2021 | 200 | 2 | 3404.0 | 10911.0 | 1278 | 3.21 | 857.0 | 2392.0 | 314 | 2.79 | 479.0 | 1454.0 | 182 | 3.04 | 413.0 | 1519.0 | 160 | 3.68 | 191.0 | 876.0 | 73 | 4.59 | 116.0 | 551.0 | 42 | 4.75 | 7.0 | 28.0 | 1 | 4.00 | 0 | 0 | 0 | 21.0 | 36.0 | 1 | 1.71 | 25.0 | 10.0 | 7 | 0.40 | 171.0 | 674.0 | 63 | 3.94 | 562.0 | 1711.0 | 220 | 3.04 | 562.0 | 1660.0 | 215 | 2.95 |
| NR | 3399 |
| Username | Hannes |
| Einbaujahr der WP | 2013-10-01 |
| PLZ des Wohnortes | 54636 |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | Alpha-Innotec LW81A |
| modulierend | Nein |
| Leistung (0/35) | 8.4 kW |
| berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 45 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | FBH |
| elektr. Verbrauch WP ohne NA gem./DB | 2400 Watt DB |
| elektr. Verbrauch HP gem./DB | 40 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung,Pumpen |
| WMZ | intern |
| Mittlere Raumtemp. | 20.0 °C |
| Mittlere Wärmequellentemperatur | 7.0 °C |
| Heizung max. Vorlauf Temp. | 40.0 °C |
| Spreizung Heizkr. | 7.0 |
| Heizflaeche | 200 m² |
| Lüftung | zenKWLWR |
| Personen | 2 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen | KFW 45 Haus Bj. 2010 mit 23 cm Außendämmung. Zentrale Lüftungsanlage mit WRG, Fußbodenheizung, thermische Solaranlage 15 m² |