Weiterhin alles Gute Michael Schumacher!
| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 3450 | Luft/Wasser | Elco Aerotop Mono 07M-RX | 7.0 | 2025 | 150 | 4 | 2671.0 | 8835.0 | 3.37 | 627.0 | 2137.0 | 3.41 | 446.0 | 1488.0 | 3.34 | 244.0 | 782.0 | 3.20 | 110.0 | 325.0 | 2.95 | 22.0 | 9.0 | 11.0 | 10.0 | 72.0 | 255.0 | 3.54 | 189.0 | 735.0 | 3.89 | 407.0 | 1418.0 | 3.48 | 524.0 | 1695.0 | 3.23 | |||||||||||||||||||||||||||||||||
| 3450 | Luft/Wasser | Elco Aerotop Mono 07M-RX | 7.0 | 2024 | 150 | 4 | 2170.0 | 7162.0 | 3.35 | 497.0 | 1625.0 | 3.27 | 240.0 | 866.0 | 3.61 | 193.0 | 654.0 | 3.39 | 136.0 | 420.0 | 3.09 | 32.0 | 60.0 | 1.88 | 10.0 | 10.0 | 10.0 | 25.0 | 38.0 | 1.52 | 117.0 | 415.0 | 3.55 | 385.0 | 1332.0 | 3.46 | 515.0 | 1752.0 | 3.40 | |||||||||||||||||||||||||||||||
| 3450 | Luft/Wasser | Elco Aerotop Mono 07M-RX | 7.0 | 2023 | 150 | 4 | 2053.0 | 6597.0 | 3.28 | 460.0 | 1475.0 | 3.21 | 386.0 | 1238.0 | 3.21 | 268.0 | 872.0 | 3.25 | 160.0 | 523.0 | 3.27 | 38.0 | 83.0 | 2.18 | 12.0 | 10.0 | 10.0 | 11.0 | 71.0 | 205.0 | 2.89 | 253.0 | 870.0 | 3.44 | 374.0 | 1331.0 | 3.56 | |||||||||||||||||||||||||||||||||
| 3450 | Luft/Wasser | Elco Aerotop Mono 07M-RX | 7.0 | 2022 | 150 | 4 | 2572.0 | 8457.0 | 3.33 | 615.0 | 2019.0 | 3.28 | 391.0 | 1398.0 | 3.58 | 410.0 | 1409.0 | 3.44 | 226.0 | 768.0 | 3.40 | 36.0 | 99.0 | 2.75 | 10.0 | 10.0 | 10.0 | 45.0 | 105.0 | 2.33 | 61.0 | 200.0 | 3.28 | 266.0 | 919.0 | 3.45 | 492.0 | 1540.0 | 3.13 |
| NR | 3450 |
| Username | Elco07 |
| Einbaujahr der WP | 2021-12-14 |
| PLZ des Wohnortes | 72144 |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | Elco Aerotop Mono 07M-RX |
| modulierend | Ja |
| Leistung (0/35) | 7.0 kW |
| berechneter Primärenergiebedarf | 90.0 kWh/m²/anno |
| WW über WP | Nein |
| WW Temperatur | 0 °C |
| WW Legionellenschaltung | |
| WW über WMZ erfasst | (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | FBH und Radiatoren |
| elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
| elektr. Verbrauch HP gem./DB | 0 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung,Pumpen |
| WMZ | extern_geeicht |
| Mittlere Raumtemp. | 21.0 °C |
| Mittlere Wärmequellentemperatur | 0.0 °C |
| Heizung max. Vorlauf Temp. | 35.0 °C |
| Spreizung Heizkr. | 5.0 |
| Heizflaeche | 150 m² |
| Lüftung | Fenster |
| Personen | 4 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen | EFH Bj2000 mit Niedrigenergisstandart, 2/3 HK 1/3 FBH. |