Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
3453 | Luft/Wasser | Daikin Altherma 3 r ech2o | 6.0 | 2024 | 134 | 3 | 1493.0 | 6282.0 | 4.21 | 595.0 | 2035.0 | 3.42 | 263.0 | 1333.0 | 5.07 | 267.0 | 1274.0 | 4.77 | 168.0 | 791.0 | 4.71 | 47.0 | 197.0 | 4.19 | 40.0 | 166.0 | 4.15 | 34.0 | 145.0 | 4.26 | 32.0 | 148.0 | 4.63 | 47.0 | 193.0 | 4.11 | ||||||||||||||||||||||||||||||||||
3453 | Luft/Wasser | Daikin Altherma 3 r ech2o | 6.0 | 2023 | 134 | 3 | 2626.0 | 11441.0 | 4.36 | 454.0 | 1974.0 | 4.35 | 426.0 | 1858.0 | 4.36 | 361.0 | 1563.0 | 4.33 | 221.0 | 1131.0 | 5.12 | 75.0 | 334.0 | 4.45 | 36.0 | 157.0 | 4.36 | 36.0 | 152.0 | 4.22 | 36.0 | 145.0 | 4.03 | 41.0 | 166.0 | 4.05 | 142.0 | 655.0 | 4.61 | 364.0 | 1523.0 | 4.18 | 434.0 | 1783.0 | 4.11 | |||||||||||||||||||||||||
3453 | Luft/Wasser | Daikin Altherma 3 r ech2o | 6.0 | 2022 | 134 | 3 | 2176.0 | 8215.0 | 3.78 | 380.0 | 1589.0 | 4.18 | 286.0 | 1269.0 | 4.44 | 116.0 | 370.0 | 3.19 | 68.0 | 201.0 | 2.96 | 46.0 | 138.0 | 3.00 | 49.0 | 153.0 | 3.12 | 111.0 | 304.0 | 2.74 | 173.0 | 485.0 | 2.80 | 360.0 | 1526.0 | 4.24 | 587.0 | 2180.0 | 3.71 |
NR | 3453 |
Username | Hyperion |
Einbaujahr der WP | 2021-02-09 |
PLZ des Wohnortes | 14913 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Daikin Altherma 3 r ech2o |
modulierend | Ja |
Leistung (0/35) | 6.0 kW |
berechneter Primärenergiebedarf | 39.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 48 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | intern > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | intern |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 32.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 134 m² |
Lüftung | dezKWL |
Personen | 3 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen |