Verbrauchsdaten für Anlage Nr. 3471
| Jahr | Pers. | GESAMT | Jan | Feb | Mär | Apr | Mai | Jun | Jul | Aug | Sep | Okt | Nov | Dez | ||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | ||
| 2025 | 2 | 1248 | 4832 | 3.87 | 480 | 1805 | 3.76 | 463 | 1697 | 3.67 | 305 | 1330 | 4.36 | |||||||||||||||||||||||||||
| 2024 | 2 | 2312 | 9480 | 4.10 | 475 | 1866 | 3.93 | 273 | 1275 | 4.67 | 273 | 1273 | 4.66 | 175 | 801 | 4.58 | 61 | 242 | 3.97 | 56 | 155 | 2.77 | 69 | 163 | 2.36 | 70 | 165 | 2.36 | 98 | 323 | 3.30 | 133 | 567 | 4.26 | 225 | 1000 | 4.44 | 404 | 1650 | 4.08 |
| 2023 | 2 | 735 | 3204 | 4.36 | 115 | 515 | 4.48 | 276 | 1190 | 4.31 | 344 | 1499 | 4.36 | |||||||||||||||||||||||||||
Vollständige Anlagendetails
Allgemeine Daten
Anlagen Nr.
3471
Username
BTSV
Gebäude Daten
PLZ
38116
Heizfläche (m²)
130
Wärmeübertragung
FBH
Raumtemperatur (°C)
20.0
Lüftung
Fenster
Endenergiebedarf (kWh/m²/anno)
76.0
berechnet nach Norm
Wärmepumpe Daten
Hersteller / Typ
Vaillant aroTHERM 756
Bauart
Luft/Wasser
Heizleistung (kW) (0/35 2/35)
7.0
Betriebsart Mono/Bi/Tri-valent
Mono
Modulierend
Ja
Einbaudatum
2023-06-01
Wärmepumpe Leistungsaufnahme (W)
Umwälzpumpe Leistungsaufnahme (W)
Wärme Quelle & Senke
Quelle
Luft
Tiefe (m)
Fläche (m²)
max. Vorlauftemperatur (°C)
27.0
Spreizung Heizkreise (°K)
4.0
Quellenpumpe Leistungsaufnahme (W)
RGK Helfer
Nein
RGK Erfahrung
Warmwasser
über WP erzeugt
Ja
über WMZ erfasst
Ja
Temp (°C)
49
Legionellenschaltung
wöchentlich
Zähler
Stromzähler
extern
Stromzähler erfasst
Kompressor,Steuerung,Pumpen
Wärmemengenzähler
extern
Informationen
Bemerkungen
Links