| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 3502 | Sole/Wasser | Novellan WS 6.2H3M | 6.0 | 2025 | 150 | 1785.5 | 7346.2 | 1063 | 4.11 | 517.0 | 2152.0 | 325 | 4.16 | 513.0 | 2083.0 | 320 | 4.06 | 316.0 | 1310.0 | 196 | 4.15 | 120.0 | 510.0 | 70 | 4.25 | 56.0 | 222.0 | 27 | 3.96 | 25.0 | 63.5 | 8 | 2.54 | 27.5 | 69.7 | 9 | 2.53 | 24.8 | 59.0 | 8 | 2.38 | 33.2 | 109.0 | 13 | 3.28 | 153.0 | 768.0 | 87 | 5.02 | |||||||||||||||||||||
| 3502 | Sole/Wasser | Novellan WS 6.2H3M | 6.0 | 2024 | 150 | 2 | 1795.0 | 7963.6 | 1259 | 4.44 | 221.0 | 1125.0 | 304 | 5.09 | 270.0 | 1140.0 | 180 | 4.22 | 220.0 | 981.0 | 141 | 4.46 | 117.0 | 489.0 | 89 | 4.18 | 39.0 | 111.0 | 16 | 2.85 | 34.0 | 85.0 | 11 | 2.50 | 38.0 | 97.0 | 14 | 2.55 | 38.0 | 95.0 | 13 | 2.50 | 25.0 | 63.6 | 8 | 2.54 | 93.0 | 422.0 | 49 | 4.54 | 286.0 | 1460.0 | 175 | 5.10 | 414.0 | 1895.0 | 259 | 4.58 | ||||||||||||
| 3502 | Sole/Wasser | Novellan WS 6.2H3M | 6.0 | 2023 | 150 | 2 | 33.8 | 144.6 | 200 | 4.28 | 33.8 | 144.6 | 200 | 4.28 |
| NR | 3502 |
| Username | felixmxr |
| Einbaujahr der WP | 2017-00-00 |
| PLZ des Wohnortes | A-8403 |
| Bauart | Sole/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | Novellan WS 6.2H3M |
| modulierend | Nein |
| Leistung (0/35) | 6.0 kW |
| berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 48 °C |
| WW Legionellenschaltung | Nein |
| WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Flachkollektoren |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | FBH |
| elektr. Verbrauch WP ohne NA gem./DB | 1500 Watt gem. |
| elektr. Verbrauch HP gem./DB | 150 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | extern > erfasst: Kompressor,Steuerung,Pumpen |
| WMZ | intern |
| Mittlere Raumtemp. | 22.0 °C |
| Mittlere Wärmequellentemperatur | 12.0 °C |
| Heizung max. Vorlauf Temp. | 42.0 °C |
| Spreizung Heizkr. | 6.0 |
| Heizflaeche | 150 m² |
| Lüftung | Fenster |
| Personen | 2 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen |